Your browser doesn't support javascript.
loading
A method for delivering the required neutron fluence in an accelerator-based boron neutron capture therapy system employing a lithium target.
Nakamura, Satoshi; Takemori, Mihiro; Nakaichi, Tetsu; Shuto, Yasunori; Kashihara, Tairo; Iijima, Kotaro; Chiba, Takahito; Nakayama, Hiroki; Urago, Yuka; Nishina, Shuka; Kobayashi, Yuta; Kishida, Hironori; Imamichi, Shoji; Takahashi, Kana; Masutani, Mitsuko; Okamoto, Hiroyuki; Nishio, Teiji; Itami, Jun; Igaki, Hiroshi.
Afiliação
  • Nakamura S; Division of Radiation Safety and Quality Assurance, National Cancer Center Hospital, 5-1-1 Tsukiji, Chuo-ku, Tokyo, 104-0045, Japan. satonaka@ncc.go.jp.
  • Takemori M; Division of Boron Neutron Capture Therapy, National Cancer Center Exploratory Oncology Research and Clinical Trial Center, 5-1-1 Tsukiji, Chuo-ku, Tokyo, 104-0045, Japan. satonaka@ncc.go.jp.
  • Nakaichi T; Medical Physics Laboratory, Division of Health Science, Graduate School of Medicine, Osaka University, 1-7 Yamadaoka, Suita City, Osaka, 565-0871, Japan. satonaka@ncc.go.jp.
  • Shuto Y; Division of Boron Neutron Capture Therapy, National Cancer Center Exploratory Oncology Research and Clinical Trial Center, 5-1-1 Tsukiji, Chuo-ku, Tokyo, 104-0045, Japan.
  • Kashihara T; Department of Radiation Oncology, National Cancer Center Hospital, 5-1-1 Tsukiji, Chuo-ku, Tokyo, 104-0045, Japan.
  • Iijima K; Division of Radiation Safety and Quality Assurance, National Cancer Center Hospital, 5-1-1 Tsukiji, Chuo-ku, Tokyo, 104-0045, Japan.
  • Chiba T; Division of Boron Neutron Capture Therapy, National Cancer Center Exploratory Oncology Research and Clinical Trial Center, 5-1-1 Tsukiji, Chuo-ku, Tokyo, 104-0045, Japan.
  • Nakayama H; Division of Radiation Safety and Quality Assurance, National Cancer Center Hospital, 5-1-1 Tsukiji, Chuo-ku, Tokyo, 104-0045, Japan.
  • Urago Y; Department of Comprehensive Oncology, Nagasaki University Graduate School of Biomedical Sciences, 5-1-1 Tsukiji, Chuo-ku, Tokyo, 104-0045, Japan.
  • Nishina S; Department of Radiological Technology, National Cancer Center Hospital, 5-1-1 Tsukiji, Chuo-ku, Tokyo, 104-0045, Japan.
  • Kobayashi Y; Division of Boron Neutron Capture Therapy, National Cancer Center Exploratory Oncology Research and Clinical Trial Center, 5-1-1 Tsukiji, Chuo-ku, Tokyo, 104-0045, Japan.
  • Kishida H; Department of Radiation Oncology, National Cancer Center Hospital, 5-1-1 Tsukiji, Chuo-ku, Tokyo, 104-0045, Japan.
  • Imamichi S; Division of Radiation Safety and Quality Assurance, National Cancer Center Hospital, 5-1-1 Tsukiji, Chuo-ku, Tokyo, 104-0045, Japan.
  • Takahashi K; Division of Radiation Safety and Quality Assurance, National Cancer Center Hospital, 5-1-1 Tsukiji, Chuo-ku, Tokyo, 104-0045, Japan.
  • Masutani M; Department of Radiological Sciences, Graduate School of Human Health Sciences, Tokyo Metropolitan University, 7-2-10 Hitashi-ogu, Arakawa-ku, Tokyo, 116-8551, Japan.
  • Okamoto H; Division of Radiation Safety and Quality Assurance, National Cancer Center Hospital, 5-1-1 Tsukiji, Chuo-ku, Tokyo, 104-0045, Japan.
  • Nishio T; Division of Radiation Safety and Quality Assurance, National Cancer Center Hospital, 5-1-1 Tsukiji, Chuo-ku, Tokyo, 104-0045, Japan.
  • Itami J; Department of Radiological Sciences, Graduate School of Human Health Sciences, Tokyo Metropolitan University, 7-2-10 Hitashi-ogu, Arakawa-ku, Tokyo, 116-8551, Japan.
  • Igaki H; Division of Radiation Safety and Quality Assurance, National Cancer Center Hospital, 5-1-1 Tsukiji, Chuo-ku, Tokyo, 104-0045, Japan.
Sci Rep ; 14(1): 11253, 2024 05 16.
Article em En | MEDLINE | ID: mdl-38755333
ABSTRACT
Accelerator-based boron neutron capture therapy (BNCT) systems employing a solid-state lithium target indicated the reduction of neutron flux over the lifetime of a target, and its reduction could represent the neutron flux model. This study proposes a novel compensatory approach for delivering the required neutron fluence and validates its clinical applicability. The proposed approach relies on the neutron flux model and the cumulative sum of real-time measurements of proton charges. The accuracy of delivering the required neutron fluence for BNCT using the proposed approach was examined in five Li targets. With the proposed approach, the required neutron fluence could be delivered within 3.0%, and within 1.0% in most cases. However, those without using the proposed approach exceeded 3.0% in some cases. The proposed approach can consider the neutron flux reduction adequately and decrease the effect of uncertainty in neutron measurements. Therefore, the proposed approach can improve the accuracy of delivering the required fluence for BNCT even if a neutron flux reduction is expected during treatment and over the lifetime of the Li target. Additionally, by adequately revising the approach, it may apply to other type of BNCT systems employing a Li target, furthering research in this direction.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Terapia por Captura de Nêutron de Boro / Lítio / Nêutrons Limite: Humans Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Terapia por Captura de Nêutron de Boro / Lítio / Nêutrons Limite: Humans Idioma: En Ano de publicação: 2024 Tipo de documento: Article