Preventing Diabetic Foot Re-Ulceration Through an Innovative Pressure and Temperature Monitoring Clinical Device.
Int J Low Extrem Wounds
; : 15347346241256159, 2024 May 21.
Article
em En
| MEDLINE
| ID: mdl-38772597
ABSTRACT
This study compared the outcome of an innovative in-shoe pressure and temperature measuring device as an adjunct to standard clinical care for diabetic foot versus standard clinical care alone. It included 88 participants with Type 2 diabetes mellitus with a history of one or more plantar foot ulceration who were already using prescription orthoses. These were randomly divided into the control group (n = 44, standard care only) and the experimental group (n = 44, standard care plus the innovative device). Both groups were monitored for re-ulceration for one year. Overall, the control group exhibited a higher number of re-ulcerations (n = 14) with 2 amputations in comparison with the experimental group (only 2 ulcerations and no amputations) at the end of the study. In conclusion, this innovative in-shoe pressure and temperature measuring device appears to reduce re-ulcerations by offering objective data for clinical decision making in the management of the diabetic high-risk foot.
Texto completo:
1
Base de dados:
MEDLINE
Idioma:
En
Ano de publicação:
2024
Tipo de documento:
Article