Your browser doesn't support javascript.
loading
Challenges in the analysis of pharmaceutical lentiviral vector products by orthogonal and complementary physical (nano)particle characterization techniques.
Stadler, Daniela; Helbig, Constanze; Wuchner, Klaus; Frank, Jürgen; Richter, Klaus; Hawe, Andrea; Menzen, Tim.
Afiliação
  • Stadler D; Coriolis Pharma Research GmbH, Fraunhoferstr. 18 b, 82152 Martinsried, Germany.
  • Helbig C; Coriolis Pharma Research GmbH, Fraunhoferstr. 18 b, 82152 Martinsried, Germany.
  • Wuchner K; Janssen Research and Development, DPDS BTDS Analytical Development, Hochstr. 201, 8200 Schaffhausen, Switzerland.
  • Frank J; Coriolis Pharma Research GmbH, Fraunhoferstr. 18 b, 82152 Martinsried, Germany.
  • Richter K; Coriolis Pharma Research GmbH, Fraunhoferstr. 18 b, 82152 Martinsried, Germany.
  • Hawe A; Coriolis Pharma Research GmbH, Fraunhoferstr. 18 b, 82152 Martinsried, Germany.
  • Menzen T; Coriolis Pharma Research GmbH, Fraunhoferstr. 18 b, 82152 Martinsried, Germany. Electronic address: tim.menzen@coriolis-pharma.com.
Eur J Pharm Biopharm ; 200: 114340, 2024 Jul.
Article em En | MEDLINE | ID: mdl-38797222
ABSTRACT
Lentiviral vectors (LVVs) are used as a starting material to generate chimeric antigen receptor (CAR) T cells. Therefore, LVVs need to be carefully analyzed to ensure safety, quality, and potency of the final product. We evaluated orthogonal and complementary analytical techniques for their suitability to characterize particulate matter (impurities and LVVs) in pharmaceutical LVV materials at development stage derived from suspension and adherent manufacturing processes. Microfluidic resistive pulse sensing (MRPS) with additional manual data fitting enabled the assessment of mode diameters for particles in the expected LVV size range in material from adherent production. LVV material from a suspension process, however, contained substantial amounts of particulate impurities which blocked MRPS cartridges. Sedimentation-velocity analytical ultracentrifugation (SV-AUC) resolved the LVV peak in material from adherent production well, whereas in more polydisperse samples from suspension production, presence of particulate impurities masked a potential signal assignable to LVVs. In interferometric light microscopy (ILM) and nanoparticle tracking analysis (NTA), lower size detection limits close to âˆ¼ 70 nm resulted in an apparent peak in particle size distributions at the expected size for LVVs emphasizing the need to interpret these data with care. Interpretation of data from dynamic light scattering (DLS) was limited by insufficient size resolution and sample polydispersity. In conclusion, the analysis of LVV products manufactured at pharmaceutical scale with current state-of-the-art physical (nano)particle characterization techniques was challenging due to the presence of particulate impurities of heterogeneous size. Among the evaluated techniques, MRPS and SV-AUC were most promising yielding acceptable results at least for material from adherent production.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Tamanho da Partícula / Ultracentrifugação / Lentivirus / Nanopartículas / Vetores Genéticos Limite: Humans Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Tamanho da Partícula / Ultracentrifugação / Lentivirus / Nanopartículas / Vetores Genéticos Limite: Humans Idioma: En Ano de publicação: 2024 Tipo de documento: Article