Your browser doesn't support javascript.
loading
Process development for the production of mesenchymal stromal cell-derived extracellular vesicles in conventional 2D systems.
Barekzai, Jan; Refflinghaus, Laura; Okpara, Maduwuike; Tasto, Lars; Tertel, Tobias; Giebel, Bernd; Czermak, Peter; Salzig, Denise.
Afiliação
  • Barekzai J; Institute of Bioprocess Engineering and Pharmaceutical Technology, University of Applied Sciences Mittelhessen, Giessen, Germany.
  • Refflinghaus L; Institute of Bioprocess Engineering and Pharmaceutical Technology, University of Applied Sciences Mittelhessen, Giessen, Germany.
  • Okpara M; Institute of Bioprocess Engineering and Pharmaceutical Technology, University of Applied Sciences Mittelhessen, Giessen, Germany.
  • Tasto L; Institute of Bioprocess Engineering and Pharmaceutical Technology, University of Applied Sciences Mittelhessen, Giessen, Germany.
  • Tertel T; Institute for Transfusion Medicine, University Hospital Essen, University of Duisburg-Essen, Essen, Germany.
  • Giebel B; Institute for Transfusion Medicine, University Hospital Essen, University of Duisburg-Essen, Essen, Germany.
  • Czermak P; Institute of Bioprocess Engineering and Pharmaceutical Technology, University of Applied Sciences Mittelhessen, Giessen, Germany; Faculty of Biology and Chemistry, Justus-Liebig-University of Giessen, Giessen Germany.
  • Salzig D; Institute of Bioprocess Engineering and Pharmaceutical Technology, University of Applied Sciences Mittelhessen, Giessen, Germany; Faculty of Biology and Chemistry, Justus-Liebig-University of Giessen, Giessen Germany. Electronic address: denise.salzig@lse.thm.de.
Cytotherapy ; 2024 Apr 27.
Article em En | MEDLINE | ID: mdl-38819363
ABSTRACT

BACKGROUND:

In recent years, the importance of extracellular vesicles (EVs) derived from mesenchymal stromal cells (MSCs) has increased significantly. For their widespread use, a standardized EV manufacturing is needed which often includes conventional, static 2D systems. For these system critical process parameters need to be determined.

METHODS:

We studied the impact of process parameters on MSC proliferation, MSC-derived particle production including EVs, EV- and MSC-specific marker expression, and particle functionality in a HaCaT cell migration assay.

RESULTS:

We found that cell culture growth surface and media affected MSCs and their secretory behavior. Interestingly, the materials that promoted MSC proliferation did not necessarily result in the most functional MSC-derived particles. In addition, we found that MSCs seeded at 4 × 103 cells cm-2 produced particles with improved functional properties compared to higher seeding densities. MSCs in a highly proliferative state did not produce the most particles, although these particles were significantly more effective in promoting HaCaT cell migration. The same correlation was found when investigating the cultivation temperature. A physiological temperature of 37°C was not optimal for particle yield, although it resulted in the most functional particles. We observed a proliferation-associated particle production and found potential correlations between particle production and glucose consumption, enabling the estimation of final particle yields.

CONCLUSIONS:

Our findings suggest that parameters, which must be defined prior to each individual cultivation and do not require complex and expensive equipment, can significantly increase MSC-derived particle production including EVs. Integrating these parameters into a standardized EV process development paves the way for robust and efficient EV manufacturing for early clinical phases.