Your browser doesn't support javascript.
loading
Development of an orbital shaker-assisted fatty acid-based switchable solvent microextraction procedure for rapid and green extraction of amoxicillin from complex matrices: Central composite design.
Elik, Adil; Demirkol, Yagmur; Ul Haq, Hameed; Boczkaj, Grzegorz; Altunay, Nail.
Afiliação
  • Elik A; Sivas Cumhuriyet University, Faculty of Science, Department of Chemistry, Sivas, Turkey.
  • Demirkol Y; Sivas Cumhuriyet University, Faculty of Science, Department of Biochemistry, Sivas, Turkey.
  • Ul Haq H; Gdansk University of Technology, Faculty of Civil and Environmental Engineering, Department of Sanitary Engineering, G. Narutowicza St. 11/12, 80-233 Gdansk, Poland.
  • Boczkaj G; Gdansk University of Technology, Faculty of Civil and Environmental Engineering, Department of Sanitary Engineering, G. Narutowicza St. 11/12, 80-233 Gdansk, Poland.
  • Sanaullah; Department of Organic Chemistry, Bioorganic Chemistry and Biotechnology, Silesian University of Technology, B. Krzywoustego 4, 44-100 Gliwice, Poland.
  • Altunay N; Sivas Cumhuriyet University, Faculty of Science, Department of Chemistry, Sivas, Turkey. Electronic address: naltunay@cumhuriyet.edu.tr.
Food Chem ; 454: 139785, 2024 Oct 01.
Article em En | MEDLINE | ID: mdl-38823199
ABSTRACT
In this study, a cheap, fast and simple orbital shaker-assisted fatty acid-based switchable solvent microextraction (OS-FASS-ME) procedure was developed for the extraction of amoxicillin (AMOX) in dairy products, pharmaceutical samples and wastewater prior to its spectrophotometric analysis. Fatty acid-based switchable solvents were investigated for extracting AMOX. The key factors of the OS-FASS-ME procedure were optimized using a central composite design. The linearity of OS-FASS-ME procedure was in the range 5-600 ng mL-1 with a correlation coefficient of 0.991. In five replicate experiments for 20 ng mL-1 of AMOX solution, the recovery and relative standard deviation were 95.8% and 2.2%, respectively. Limits of detection and quantification were found 1.5 ng mL-1 and 5 ng mL-1, respectively. The accuracy, precision, robustness and selectivity of the OS-FASS-ME procedure were investigated in detail under optimum conditions. The OS-FASS-ME procedure was applied to milk, cheese, wastewater, syrups and tablets. A comparison of the results obtained from the reference method and the OS-FASS-ME method showed that the OS-FASS-ME procedure can be successfully applied to complex matrices.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Ácidos Graxos / Microextração em Fase Líquida / Amoxicilina Limite: Animals Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Ácidos Graxos / Microextração em Fase Líquida / Amoxicilina Limite: Animals Idioma: En Ano de publicação: 2024 Tipo de documento: Article