Your browser doesn't support javascript.
loading
Biothiols-activated near-infrared frequency up-conversion luminescence probe for early evaluation of drug-induced hepatotoxicity.
Ma, Xiao; Lan, Qingchun; Pan, Shufen; Han, Yuting; Liu, Yi; Wu, Yongquan.
Afiliação
  • Ma X; Key Laboratory of Organo-Pharmaceutical Chemistry of Jiangxi Province, School of Chemistry and Chemical Engineering, Gannan Normal University, Ganzhou, 341000, PR China.
  • Lan Q; Key Laboratory of Organo-Pharmaceutical Chemistry of Jiangxi Province, School of Chemistry and Chemical Engineering, Gannan Normal University, Ganzhou, 341000, PR China.
  • Pan S; Key Laboratory of Organo-Pharmaceutical Chemistry of Jiangxi Province, School of Chemistry and Chemical Engineering, Gannan Normal University, Ganzhou, 341000, PR China.
  • Han Y; Key Laboratory of Organo-Pharmaceutical Chemistry of Jiangxi Province, School of Chemistry and Chemical Engineering, Gannan Normal University, Ganzhou, 341000, PR China.
  • Liu Y; School of Engineering, China Pharmaceutical University, Nanjing, 211198, PR China. Electronic address: yiliu@cpu.edu.cn.
  • Wu Y; Key Laboratory of Organo-Pharmaceutical Chemistry of Jiangxi Province, School of Chemistry and Chemical Engineering, Gannan Normal University, Ganzhou, 341000, PR China. Electronic address: wyq@gnnu.edu.cn.
Anal Chim Acta ; 1312: 342768, 2024 Jul 11.
Article em En | MEDLINE | ID: mdl-38834271
ABSTRACT
A novel biothiols-sensitive near-infrared (NIR) fluorescent probe RhDN based on a rhodamine skeleton was developed for early detection of drug-induced hepatotoxicity in living mice. RhDN can be used not only as a conventional large stokes shift fluorescent (FL) probe, but also as a kind of anti-Stokes frequency upconversion luminescence (FUCL) molecular probe, which represents a long wavelength excitation (808 nm) to short wavelength emission (760 nm), and response to Cys/Hcy/GSH with high sensitivity. Compared with traditional FL methods, the FUCL method exhibited a lower detection limit of Cys, Hcy, and GSH in 75.1 nM, 101.8 nM, and 84.9 nM, respectively. We exemplify RhDN for tracking endogenously biothiols distribution in living cells and further realize real-time in vivo bioimaging of biothiols activity in mice with dual-mode luminescence system. Moreover, RhDN has been successfully applied to visualize the detection of drug-induced hepatotoxicity in living mice. Overall, this report presents a unique approach to the development of large stokes shift NIR FUCL molecular probes for in vitro and in vivo biothiols biosensing.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Doença Hepática Induzida por Substâncias e Drogas / Corantes Fluorescentes Limite: Animals / Humans Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Doença Hepática Induzida por Substâncias e Drogas / Corantes Fluorescentes Limite: Animals / Humans Idioma: En Ano de publicação: 2024 Tipo de documento: Article