Your browser doesn't support javascript.
loading
Development of a Low-Cost Markerless Optical Motion Capture System for Gait Analysis and Anthropometric Parameter Quantification.
Espitia-Mora, Laura Alejandra; Vélez-Guerrero, Manuel Andrés; Callejas-Cuervo, Mauro.
Afiliação
  • Espitia-Mora LA; Software Research Group, Universidad Pedagógica y Tecnológica de Colombia, Tunja 150002, Colombia.
  • Vélez-Guerrero MA; Software Research Group, Universidad Pedagógica y Tecnológica de Colombia, Tunja 150002, Colombia.
  • Callejas-Cuervo M; Software Research Group, Universidad Pedagógica y Tecnológica de Colombia, Tunja 150002, Colombia.
Sensors (Basel) ; 24(11)2024 May 24.
Article em En | MEDLINE | ID: mdl-38894161
ABSTRACT
Technological advancements have expanded the range of methods for capturing human body motion, including solutions involving inertial sensors (IMUs) and optical alternatives. However, the rising complexity and costs associated with commercial solutions have prompted the exploration of more cost-effective alternatives. This paper presents a markerless optical motion capture system using a RealSense depth camera and intelligent computer vision algorithms. It facilitates precise posture assessment, the real-time calculation of joint angles, and acquisition of subject-specific anthropometric data for gait analysis. The proposed system stands out for its simplicity and affordability in comparison to complex commercial solutions. The gathered data are stored in comma-separated value (CSV) files, simplifying subsequent analysis and data mining. Preliminary tests, conducted in controlled laboratory environments and employing a commercial MEMS-IMU system as a reference, revealed a maximum relative error of 7.6% in anthropometric measurements, with a maximum absolute error of 4.67 cm at average height. Stride length measurements showed a maximum relative error of 11.2%. Static joint angle tests had a maximum average error of 10.2%, while dynamic joint angle tests showed a maximum average error of 9.06%. The proposed optical system offers sufficient accuracy for potential application in areas such as rehabilitation, sports analysis, and entertainment.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Algoritmos / Antropometria / Análise da Marcha / Marcha Limite: Adult / Humans / Male Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Algoritmos / Antropometria / Análise da Marcha / Marcha Limite: Adult / Humans / Male Idioma: En Ano de publicação: 2024 Tipo de documento: Article