Your browser doesn't support javascript.
loading
The Reliability and Validity of the OneStep Smartphone Application for Gait Analysis among Patients Undergoing Rehabilitation for Unilateral Lower Limb Disability.
Marom, Pnina; Brik, Michael; Agay, Nirit; Dankner, Rachel; Katzir, Zoya; Keshet, Naama; Doron, Dana.
Afiliação
  • Marom P; Reuth Research and Development Institute, Reuth Rehabilitation Hospital, Tel Aviv 6772830, Israel.
  • Brik M; Department of Health Promotion, School of Public Health, Faculty of Medical & Health Sciences, Tel Aviv University, Tel Aviv 6997801, Israel.
  • Agay N; Reuth Research and Development Institute, Reuth Rehabilitation Hospital, Tel Aviv 6772830, Israel.
  • Dankner R; Unit for Cardiovascular Epidemiology, The Gertner Institute for Epidemiology and Health Policy Research, Sheba Medical Center, Tel Hashomer, Ramat Gan 5262000, Israel.
  • Katzir Z; Reuth Research and Development Institute, Reuth Rehabilitation Hospital, Tel Aviv 6772830, Israel.
  • Keshet N; Unit for Cardiovascular Epidemiology, The Gertner Institute for Epidemiology and Health Policy Research, Sheba Medical Center, Tel Hashomer, Ramat Gan 5262000, Israel.
  • Doron D; Department of Epidemiology and Preventive Medicine, School of Public Health, Faculty of Medical & Health Sciences, Tel Aviv University, Tel Aviv 6997801, Israel.
Sensors (Basel) ; 24(11)2024 Jun 02.
Article em En | MEDLINE | ID: mdl-38894386
ABSTRACT
An easy-to-use and reliable tool is essential for gait assessment of people with gait pathologies. This study aimed to assess the reliability and validity of the OneStep smartphone application compared to the C-Mill-VR+ treadmill (Motek, Nederlands), among patients undergoing rehabilitation for unilateral lower extremity disability. Spatiotemporal gait parameters were extracted from the treadmill and from two smartphones, one on each leg. Inter-device reliability was evaluated using Pearson correlation, intra-cluster correlation coefficient (ICC), and Cohen's d, comparing the application's readings from the two phones. Validity was assessed by comparing readings from each phone to the treadmill. Twenty-eight patients completed the study; the median age was 45.5 years, and 61% were males. The ICC between the phones showed a high correlation (r = 0.89-1) and good-to-excellent reliability (ICC range, 0.77-1) for all the gait parameters examined. The correlations between the phones and the treadmill were mostly above 0.8. The ICC between each phone and the treadmill demonstrated moderate-to-excellent validity for all the gait parameters (range, 0.58-1). Only 'step length of the impaired leg' showed poor-to-good validity (range, 0.37-0.84). Cohen's d effect size was small (d < 0.5) for all the parameters. The studied application demonstrated good reliability and validity for spatiotemporal gait assessment in patients with unilateral lower limb disability.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Extremidade Inferior / Aplicativos Móveis / Smartphone / Análise da Marcha / Marcha Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Extremidade Inferior / Aplicativos Móveis / Smartphone / Análise da Marcha / Marcha Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2024 Tipo de documento: Article