Your browser doesn't support javascript.
loading
Design of Wearable Textile Electrodes for the Monitorization of Patients with Heart Failure.
Sánchez, María Jesús; Scagliusi, Santiago J Fernández; Giménez-Miranda, Luis; Pérez, Pablo; Medrano, Francisco Javier; Olmo Fernández, Alberto.
Afiliação
  • Sánchez MJ; Departamento de Tecnología Electrónica, E.T.S. de Ingeniería Informática, Universidad de Sevilla, Avda. Reina Mercedes s/n., 41012 Seville, Spain.
  • Scagliusi SJF; Departamento de Tecnología Electrónica, E.T.S. de Ingeniería Informática, Universidad de Sevilla, Avda. Reina Mercedes s/n., 41012 Seville, Spain.
  • Giménez-Miranda L; Instituto de Microelectrónica de Sevilla, IMSE-CNM, Universidad de Sevilla, CSIC. C\Américo Vespucio 28, 41092 Seville, Spain.
  • Pérez P; Instituto de Biomedicina de Sevilla (IBIS-US), Hospital Universitario Virgen del Rocío (HUVR), 41013 Seville, Spain.
  • Medrano FJ; Departamento de Tecnología Electrónica, E.T.S. de Ingeniería Informática, Universidad de Sevilla, Avda. Reina Mercedes s/n., 41012 Seville, Spain.
  • Olmo Fernández A; Instituto de Microelectrónica de Sevilla, IMSE-CNM, Universidad de Sevilla, CSIC. C\Américo Vespucio 28, 41092 Seville, Spain.
Sensors (Basel) ; 24(11)2024 Jun 04.
Article em En | MEDLINE | ID: mdl-38894428
ABSTRACT
Heart failure is a severe medical condition with an important worldwide incidence that occurs when the heart is unable to efficiently pump the patient's blood throughout the body. The monitoring of edema in the lower limbs is one of the most efficient ways to control the evolution of the condition. Impedance spectroscopy has been proposed as an efficient technique to monitor body volume in patients with heart failure. It is necessary to research new wearable devices for remote patient monitoring, which can be easily worn by patients in a continuous way. In this work, we design and implement new wearable textile electrodes for the monitoring of edema evolution in patients with heart failure. Impedance spectroscopy measurements were carried out in 5 healthy controls and 2 patients with heart failure using our wearable electrodes for 3 days. The results show the appropriateness of impedance spectroscopy and our wearable electrodes to monitor body volume evolution. Impedance spectroscopy is shown to be an efficient marker of the presence of edema in heart failure patients. Initial patient positive feedback was obtained for the use of the wearable device.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Têxteis / Eletrodos / Espectroscopia Dielétrica / Dispositivos Eletrônicos Vestíveis / Insuficiência Cardíaca Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Têxteis / Eletrodos / Espectroscopia Dielétrica / Dispositivos Eletrônicos Vestíveis / Insuficiência Cardíaca Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2024 Tipo de documento: Article