Your browser doesn't support javascript.
loading
Comparing the Drop Vertical Jump Tracking Performance of the Azure Kinect to the Kinect V2.
Abdelnour, Patrik; Zhao, Kevin Y; Babouras, Athanasios; Corban, Jason Philip Aaron Hiro; Karatzas, Nicolaos; Fevens, Thomas; Martineau, Paul Andre.
Afiliação
  • Abdelnour P; Faculty of Medicine and Health Sciences, McGill University, 3605 Rue de la Montagne, Montreal, QC H3G 2M1, Canada.
  • Zhao KY; Faculty of Medicine and Health Sciences, McGill University, 3605 Rue de la Montagne, Montreal, QC H3G 2M1, Canada.
  • Babouras A; Division of Orthopaedic Surgery, McGill University Health Centre, 1650 Cedar Ave, Montreal, QC H3G 1A4, Canada.
  • Corban JPAH; Department of Experimental Surgery, McGill University, 845 Sherbrooke St W, Montreal, QC H3A 0G4, Canada.
  • Karatzas N; Division of Orthopaedic Surgery, McGill University Health Centre, 1650 Cedar Ave, Montreal, QC H3G 1A4, Canada.
  • Fevens T; Faculty of Medicine and Health Sciences, McGill University, 3605 Rue de la Montagne, Montreal, QC H3G 2M1, Canada.
  • Martineau PA; Department of Computer Science and Software Engineering, Concordia University, 1455 De Maisonneuve Blvd. W., Montreal, QC H3G 1M8, Canada.
Sensors (Basel) ; 24(12)2024 Jun 13.
Article em En | MEDLINE | ID: mdl-38931598
ABSTRACT
Traditional motion analysis systems are impractical for widespread screening of non-contact anterior cruciate ligament (ACL) injury risk. The Kinect V2 has been identified as a portable and reliable alternative but was replaced by the Azure Kinect. We hypothesize that the Azure Kinect will assess drop vertical jump (DVJ) parameters associated with ACL injury risk with similar accuracy to its predecessor, the Kinect V2. Sixty-nine participants performed DVJs while being recorded by both the Azure Kinect and the Kinect V2 simultaneously. Our software analyzed the data to identify initial coronal, peak coronal, and peak sagittal knee angles. Agreement between the two systems was evaluated using the intraclass correlation coefficient (ICC). There was poor agreement between the Azure Kinect and the Kinect V2 for initial and peak coronal angles (ICC values ranging from 0.135 to 0.446), and moderate agreement for peak sagittal angles (ICC = 0.608, 0.655 for left and right knees, respectively). At this point in time, the Azure Kinect system is not a reliable successor to the Kinect V2 system for assessment of initial coronal, peak coronal, and peak sagittal angles during a DVJ, despite demonstrating superior tracking of continuous knee angles. Alternative motion analysis systems should be explored.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Lesões do Ligamento Cruzado Anterior Limite: Adult / Female / Humans / Male Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Lesões do Ligamento Cruzado Anterior Limite: Adult / Female / Humans / Male Idioma: En Ano de publicação: 2024 Tipo de documento: Article