In Search of a Common Language: The Standardized Electrode Nomenclature for Stereoelectroencephalography Applications.
Chiu, Michelle Y; Bolton, Jeffrey; Raskin, Jeffrey S; Curry, Daniel J; Weiner, Howard L; Pearl, Phillip L; Stone, Scellig.
Afiliação
  • Chiu MY; Epilepsy Division, Department of Neurology, Boston Children's Hospital, Harvard Medical School, Boston, Massachusetts, U.S.A.
  • Bolton J; Epilepsy Division, Department of Neurology, Boston Children's Hospital, Harvard Medical School, Boston, Massachusetts, U.S.A.
  • Raskin JS; Department of Neurological Surgery, Northwestern University Feinberg School of Medicine, Chicago, Illinois, U.S.A.
  • Curry DJ; Division of Pediatric Neurosurgery, Ann & Robert H. Lurie Children's Hospital, Chicago, Illinois, U.S.A.
  • Weiner HL; Division of Pediatric Neurosurgery, Department of Surgery, Texas Children's Hospital and Department of Neurosurgery, Baylor College of Medicine, Houston, Texas, U.S.A.; and.
  • Pearl PL; Division of Pediatric Neurosurgery, Department of Surgery, Texas Children's Hospital and Department of Neurosurgery, Baylor College of Medicine, Houston, Texas, U.S.A.; and.
  • Stone S; Epilepsy Division, Department of Neurology, Boston Children's Hospital, Harvard Medical School, Boston, Massachusetts, U.S.A.
J Clin Neurophysiol ; 41(5): 405-409, 2024 Jul 01.
Article em En | MEDLINE | ID: mdl-38935653
ABSTRACT

PURPOSE:

Stereoelectroencephalography (SEEG) is widely performed on individuals with medically refractory epilepsy for whom invasive seizure localization is desired. Despite increasing adoption in many centers across the world, no standardized electrode naming convention exists, generating confusion among both clinical and research teams.

METHODS:

We have developed a novel nomenclature, named the Standardized Electrode Nomenclature for SEEG Applications system. Concise, unique, informative, and unambiguous labels provide information about entry point, deep targets, and relationships between electrodes. Inter-rater agreement was evaluated by comparing original electrode names from 10 randomly sampled cases (including 136 electrodes) with those prospectively assigned by four additional blinded raters.

RESULTS:

The Standardized Electrode Nomenclature for SEEG Application system was prospectively implemented in 40 consecutive patients undergoing SEEG monitoring at our institution, creating unique electrode names in all cases, and facilitating implantation design, SEEG recording and mapping interpretation, and treatment planning among neurosurgeons, neurologists, and neurophysiologists. The inter-rater percent agreement for electrode names among two neurosurgeons, two epilepsy neurologists, and one neurosurgical fellow was 97.5%.

CONCLUSIONS:

This standardized naming convention, Standardized Electrode Nomenclature for SEEG Application, provides a simple, concise, reproducible, and informative method for specifying the target(s) and relative position of each SEEG electrode in each patient, allowing for successful sharing of information in both the clinical and research settings. General adoption of this nomenclature could pave the way for improved communication and collaboration between institutions.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Técnicas Estereotáxicas / Eletrodos Implantados / Eletroencefalografia / Terminologia como Assunto Limite: Female / Humans / Male Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Técnicas Estereotáxicas / Eletrodos Implantados / Eletroencefalografia / Terminologia como Assunto Limite: Female / Humans / Male Idioma: En Ano de publicação: 2024 Tipo de documento: Article