Your browser doesn't support javascript.
loading
Based on Fe and Ni prepared organic colloidal materials as efficient oxide nanozymes for chemiluminescence detection of GSH and Hg(II) ions.
Yan, Xiluan; Cheng, Shiyun; Xiao, Yipi; Wu, Shuangbin; Mu, Hongyi; Shi, Zhiying; Guo, Liang; Ai, Fanrong; Zheng, Xiangjuan.
Afiliação
  • Yan X; School of Pharmacy, Jiangxi Medical College, Nanchang University, Nanchang 330006, PR China; School of Chemistry and Chemical Engineering, Nanchang University, Nanchang 330031, PR China.
  • Cheng S; School of Chemistry and Chemical Engineering, Nanchang University, Nanchang 330031, PR China.
  • Xiao Y; Nanchang Hongdu Hospital of TCM, Nanchang 330013, PR China.
  • Wu S; School of Pharmacy, Jiangxi Medical College, Nanchang University, Nanchang 330006, PR China.
  • Mu H; School of Chemistry and Chemical Engineering, Nanchang University, Nanchang 330031, PR China.
  • Shi Z; School of Chemistry and Chemical Engineering, Nanchang University, Nanchang 330031, PR China.
  • Guo L; Sino German Joint Research Institute, Nanchang University, Nanchang 330096, PR China.
  • Ai F; School of Advanced Manufacturing, Nanchang University, Nanchang 330031, PR China.
  • Zheng X; School of Chemistry and Chemical Engineering, Nanchang University, Nanchang 330031, PR China. Electronic address: zhengxiangjuan@ncu.edu.cn.
Spectrochim Acta A Mol Biomol Spectrosc ; 321: 124696, 2024 Nov 15.
Article em En | MEDLINE | ID: mdl-38950475
ABSTRACT
Metal-organic gels (MOGs) are a type of metal-organic colloid material with a large specific surface area, loose porous structure, and open metal active sites. In this work, FeNi-MOGs were synthesized by the simple one-step static method, using Fe(III) and Ni(II) as the central metal ions and terephthalic acid as the organic ligand. The prepared FeNi-MOGs could effectively catalyze the chemiluminescence of luminol without the involvement of H2O2, which exhibited good catalytic activity. Then, the multifunctional detected platform was constructed for the detection of GSH and Hg2+, based on the antioxidant capacity of GSH, and the strong affinity between mercury ion (Hg2+) and GSH which inactivated the antioxidant capacity of GSH. The experimental limits of detection (LOD) for GSH and Hg2+ were 76 nM and 210 nM, and the detection ranges were 2-100 µM and 8-4000 µM, respectively. The as-proposed sensor had good performance in both detection limit and detection range of GSH and Hg2+, which fully met the needs of daily life. Surprisingly, the sensor had low detection limits and an extremely wide detection range for Hg2+, spanning five orders of magnitude. Furthermore, the detection of mercury ions in actual lake water and GSH in human serum showed good results, with recovery rates ranging from 90.10 % to 105.37 %, which proved that the method was accurate and reliable. The as-proposed sensor had great potential as the platform for GSH and Hg2+ detection applications.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Coloides / Limite de Detecção / Glutationa / Ferro / Medições Luminescentes / Mercúrio / Níquel Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Coloides / Limite de Detecção / Glutationa / Ferro / Medições Luminescentes / Mercúrio / Níquel Idioma: En Ano de publicação: 2024 Tipo de documento: Article