Effects of dabigatran, rivaroxaban, and apixaban on fibrin network permeability, thrombin generation, and fibrinolysis.
Taune, Viktor Schutz; Zabczyk, Michal; He, Shu; Ågren, Anna; Blombäck, Margareta; Wallén, Håkan; Skeppholm, Mika.
Afiliação
  • Taune VS; Division of Cardiovascular Medicine, Department of Clinical Sciences, Karolinska Institutet, Danderyd Hospital, Stockholm, Sweden.
  • Zabczyk M; Department of Thromboembolic Disorders, Institute of Cardiology, Medical College, John Paul II Hospital, Jagiellonian University, Kraków, Poland.
  • He S; Division of Cardiovascular Medicine, Department of Clinical Sciences, Karolinska Institutet, Danderyd Hospital, Stockholm, Sweden.
  • Ågren A; Division of Cardiovascular Medicine, Department of Clinical Sciences, Karolinska Institutet, Danderyd Hospital, Stockholm, Sweden.
  • Blombäck M; Department of Molecular Medicine & Surgery (Coagulation), Karolinska Institutet, Stockholm, Sweden.
  • Wallén H; Department of Molecular Medicine & Surgery (Coagulation), Karolinska Institutet, Stockholm, Sweden.
  • Skeppholm M; Division of Cardiovascular Medicine, Department of Clinical Sciences, Karolinska Institutet, Danderyd Hospital, Stockholm, Sweden.
Scand J Clin Lab Invest ; : 1-11, 2024 Jul 02.
Article em En | MEDLINE | ID: mdl-38953609
ABSTRACT

INTRODUCTION:

There are important pharmacological differences between direct oral anticoagulants (DOAC) and a deeper knowledge of how they influence different aspects of hemostasis in patients on treatment is desirable. MATERIALS AND

METHODS:

Blood samples from patients on dabigatran (n = 23), rivaroxaban (n = 26), or apixaban (n = 20) were analyzed with a fibrin network permeability assay, a turbidimetric clotting and lysis assay, the calibrated automated thrombogram (CAT), plasma levels of thrombin-antithrombin complex (TAT) and D-dimer, as well as DOAC concentrations, PT-INR and aPTT. As a comparison, we also analyzed samples from 27 patients on treatment with warfarin.

RESULTS:

Patients on dabigatran had a more permeable fibrin network, longer lag time (CAT and turbidimetric assay), and lower levels of D-dimer in plasma, compared with patients on rivaroxaban- and apixaban treatment, and a more permeable fibrin network than patients on warfarin. Clot lysis time was slightly longer in patients on dabigatran than in patients on rivaroxaban. Warfarin patients formed a more permeable fibrin network than patients on apixaban, had longer lag time than patients on rivaroxaban (CAT assay), and lower peak thrombin and ETP compared to patients on treatment with both FXa-inhibitors.

CONCLUSIONS:

Results from this study indicate dabigatran treatment is a more potent anticoagulant than apixaban and rivaroxaban. However, as these results are not supported by clinical data, they are probably more related to the assays used and highlight the difficulty of measuring and comparing the effect of anticoagulants.