Your browser doesn't support javascript.
loading
Sensitive detection of uric acid based on low-triggering-potential cathodic luminol electrochemiluminescence achieved by ReS2 nanosheets.
Zhang, Yahui; Wang, Xinyi; Jia, Changbo; Dong, Yongping.
Afiliação
  • Zhang Y; School of Chemistry and Chemical Engineering, Anhui University of Technology, Maanshan, 243002, Anhui, China.
  • Wang X; School of Chemistry and Chemical Engineering, Anhui University of Technology, Maanshan, 243002, Anhui, China.
  • Jia C; School of Chemistry and Chemical Engineering, Anhui University of Technology, Maanshan, 243002, Anhui, China.
  • Dong Y; School of Chemistry and Chemical Engineering, Anhui University of Technology, Maanshan, 243002, Anhui, China. dongyp524@163.com.
Anal Bioanal Chem ; 416(22): 4887-4896, 2024 Sep.
Article em En | MEDLINE | ID: mdl-38953916
ABSTRACT
The majority of previously reported cathodic electrochemiluminescence (ECL) systems often required very negative potential to be carried out, which has greatly limited their applications in the sensing field. Screening high-performance cathodic ECL systems with low triggering potential is a promising way to broaden their applications. In this work, rhenium disulfide nanosheets (ReS2 NS) have been revealed as an efficient co-promoter to realize low-triggering-potential cathodic luminol ECL. One strong cathodic ECL signal appeared at a potential of -0.3 V and one anodic ECL peak was obtained at -0.15 V under the reverse potential scan, which were caused by electrogenerated reactive oxygen species (ROS) from hydrogen peroxide. The generation of strong luminol ECL at low potential was the result of the electrocatalytic effect of ReS2 NS on the reduction of H2O2. The scavenging effect of uric acid (UA) on the ROS could significantly inhibit the cathodic ECL. As a result, an ECL sensor was proposed, which showed outstanding performance for the detection of UA in the range of 10 nM to 0.1 mM with a low detection limit of 1.53 nM. Moreover, the ECL sensor was successfully applied in the sensitive detection of UA in real samples. This work provides a new avenue to establish a low-potential cathodic ECL system, which will sufficiently expand the potential application of cathodic ECL in the sensing field.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article