Affordable Implementation of a Point-of-Care Ultrasound Program in a Large Tertiary Neonatal Intensive Care Unit to Assess Umbilical Venous Catheter Tips and Aid Central Placement.
Wren, John T; Eslambolchi, Azadeh; Clark, Kristen; Najaf, Tasnim.
Afiliação
  • Wren JT; Division of Neonatology, Department of Pediatrics, University of Iowa Hospitals and Clinics, Iowa City, Iowa.
  • Eslambolchi A; Division of Pediatric Radiology, Mallinckrodt Institute of Radiology, Washington University, St. Louis, Missouri.
  • Clark K; Neonatal Intensive Care Unit, Saint Louis Children's Hospital, BJC Healthcare, St. Louis, Missouri.
  • Najaf T; Division of Newborn Medicine, Department of Pediatrics, Washington University, St. Louis, Missouri.
Am J Perinatol ; 2024 Jul 19.
Article em En | MEDLINE | ID: mdl-38955218
ABSTRACT

OBJECTIVE:

This study aimed to implement a point-of-care ultrasound (POCUS) program into a large neonatal intensive care unit (NICU) to enhance care by improving (1) umbilical venous catheter (UVC) tip identification and (2) central placement. STUDY

DESIGN:

A POCUS program was established with core providers who received training from external and internal experts. A prospective study (n = 94) compared the accuracy of UVC identification between neonatology-performed ultrasound (NeoUS) and X-ray relative to a referent of radiology-interpreted ultrasound. Finally, an ultrasound-guided UVC insertion protocol was introduced to rescue noncentral traditionally placed catheters (n = 37).

RESULTS:

Program implementation trained six providers for a total cost of approximately $10,500 USD. NeoUS was more accurate than X-ray at identifying UVC location (81.9 vs. 60.6%) with improved sensitivity and specificity (80.0 and 84.6 vs. 52.5 and 66.7%, respectively). POCUS guidance was able to rescue 89.2% of catheters that were originally noncentral.

CONCLUSION:

POCUS implementation in a large NICU is feasible, affordable, and can improve quality of care. KEY POINTS · POCUS implementation is feasible and affordable.. · POCUS is more accurate than X-ray at monitoring UVCs.. · Central UVC placement can be increased with POCUS..

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article