Evaluation and validation of a PrintrLab-based LAMP assay to identify Trypanosoma cruzi in newborns in Bolivia: a proof-of-concept study.
Lancet Microbe
; 5(9): 100887, 2024 Sep.
Article
em En
| MEDLINE
| ID: mdl-38971173
ABSTRACT
BACKGROUND:
Vertical transmission of Trypanosoma cruzi represents approximately 20% of new Chagas disease cases. Early detection and treatment for women of childbearing age and newborns is a public health priority, but the lack of a simple and reliable diagnostic test remains a major barrier. We aimed to evaluate the performance of a point-of-care loop-mediated isothermal amplification (LAMP) assay for the detection of T cruzi.METHODS:
In this proof-of-concept study, we coupled a low-cost 3D printer repurposed for sample preparation and amplification (PrintrLab) to the Eiken T cruzi-LAMP prototype to detect vertically transmitted T cruzi, which we compared with standardised PCR and with the gold-standard algorithm (microscopy at birth and 2 months and serological study several months later). We screened pregnant women from two hospitals in the Bolivian Gran Chaco province, and those who were seropositive for T cruzi were offered the opportunity for their newborns to be enrolled in the study. Newborns were tested by microscopy, LAMP, and PCR at birth and 2 months, and by serology at 8 months.FINDINGS:
Between April 23 and Nov 17, 2018, 986 mothers were screened, among whom 276 were seropositive for T cruzi (28·0% prevalence, 95% CI 25·6-31·2). In total, 224 infants born to 221 seropositive mothers completed 8 months of follow-up. Congenital transmission was detected in nine of the 224 newborns (4·0% prevalence, 1·9-7·5) by direct microscopy observation, and 14 more cases were diagnosed serologically (6·3%, 3·6-10·3), accounting for an overall vertical transmission rate of 10·3% (6·6-15·0; 23 of 224). All microscopy-positive newborns were positive by PrintrLab-LAMP and by PCR, while these techniques respectively detected four and five extra positive cases among the remaining 215 microscopy-negative newborns.INTERPRETATION:
The PrintrLab-LAMP yielded a higher sensitivity than microscopy-based analysis. Considering the simpler use and expected lower cost of LAMP compared with PCR, our findings encourage its evaluation in a larger study over a wider geographical area.FUNDING:
Inter-American Development Bank.
Texto completo:
1
Base de dados:
MEDLINE
Assunto principal:
Trypanosoma cruzi
/
Doença de Chagas
/
Transmissão Vertical de Doenças Infecciosas
/
Técnicas de Amplificação de Ácido Nucleico
/
Técnicas de Diagnóstico Molecular
Limite:
Adult
/
Female
/
Humans
/
Newborn
/
Pregnancy
País como assunto:
America do sul
/
Bolivia
Idioma:
En
Ano de publicação:
2024
Tipo de documento:
Article