Your browser doesn't support javascript.
loading
Quantification of arsenic in real samples using a spectrophotometric cloud point extraction of the formed ion pair with astrazon orange G.
Sari, Abdullah A A; El-Bahy, Salah M; Debbabi, Khaled F; El-Sayed, Refat; Amin, Alaa S.
Afiliação
  • Sari AAA; Department of Chemistry, University College in Al-Jamoum, Umm Al-Qura University, 21955 Makkah, Saudi Arabia.
  • El-Bahy SM; Department of Chemistry, Turabah University College, Taif University, Taif, Saudi Arabia.
  • Debbabi KF; Department of Chemistry, University College in Al-Jamoum, Umm Al-Qura University, 21955 Makkah, Saudi Arabia; Department of Chemistry, High Institute of Applied Science & Technology of Monastir, Monastir, Tunisia.
  • El-Sayed R; Department of Chemistry, University College in Al-Jamoum, Umm Al-Qura University, 21955 Makkah, Saudi Arabia; Chemistry Department, Faculty of Science, Benha University, Benha, Egypt.
  • Amin AS; Chemistry Department, Faculty of Science, Benha University, Benha, Egypt. Electronic address: asamin2005@hotmail.com.
Spectrochim Acta A Mol Biomol Spectrosc ; 322: 124787, 2024 Dec 05.
Article em En | MEDLINE | ID: mdl-38972096
ABSTRACT
A novel cloud-point extraction (CPE) procedure for the determination of ultra-trace amounts of arsenic species in real samples, purchased from the local market by spectrophotometer was developed. Inorganic arsenic species analysis in water, beverages, and foods has become increasingly important in recent years, as arsenic species are considered carcinogenic and are assessed at significant levels in samples. The technique is established on a selective ternary complex of As(V) with astrazon orange G (AOG+) in the presence of tartaric acid and polyethylene glycol tertoctylphenyl ether (Triton X-114) at pH 4.0. The calibration curve developed within range 3.0-160 ng/mL with a correlation coefficient of 0.9988 for As(V) provided a preconcentration factor of 200 and a limit of detection (3S blank/m) of 0.88 ng/mL under optimum investigation conditions. The results of molar absorptivity and Sandell sensitivity are calculated and found to be 4.38 × 105 L/mol cm and 0.018 ng cm-2, respectively. The statistical treatment of data obtained from the proposed and GF-AAS procedures are compared in terms of Student's t-tests and variance ratio F-tests has revealed no significant differences. The methodology has been effectively confirmed by assessing real samples and comparing it to the GF-AAS method statistically.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Arsênio / Espectrofotometria / Compostos Azo / Limite de Detecção Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Arsênio / Espectrofotometria / Compostos Azo / Limite de Detecção Idioma: En Ano de publicação: 2024 Tipo de documento: Article