Effect of positive end expiratory pressure on non-hypoxic apnea time and atelectasis during induction of anesthesia in infant: A randomized controlled trial.
Kim, Eun-Hee; Park, Jung-Bin; Kang, Pyoyoon; Ji, Sang-Hwan; Jang, Young-Eun; Lee, Ji-Hyun; Kim, Jin-Tae; Kim, Hee-Soo.
Afiliação
  • Kim EH; Department of Anesthesiology and Pain Medicine, Seoul National University College of Medicine, Seoul National University Hospital, Seoul, Republic of Korea.
  • Park JB; Department of Anesthesiology and Pain Medicine, Seoul National University College of Medicine, Seoul National University Hospital, Seoul, Republic of Korea.
  • Kang P; Department of Anesthesiology and Pain Medicine, Seoul National University College of Medicine, Seoul National University Hospital, Seoul, Republic of Korea.
  • Ji SH; Department of Anesthesiology and Pain Medicine, Seoul National University College of Medicine, Seoul National University Hospital, Seoul, Republic of Korea.
  • Jang YE; Department of Anesthesiology and Pain Medicine, Seoul National University College of Medicine, Seoul National University Hospital, Seoul, Republic of Korea.
  • Lee JH; Department of Anesthesiology and Pain Medicine, Seoul National University College of Medicine, Seoul National University Hospital, Seoul, Republic of Korea.
  • Kim JT; Department of Anesthesiology and Pain Medicine, Seoul National University College of Medicine, Seoul National University Hospital, Seoul, Republic of Korea.
  • Kim HS; Department of Anesthesiology and Pain Medicine, Seoul National University College of Medicine, Seoul National University Hospital, Seoul, Republic of Korea.
Paediatr Anaesth ; 2024 Jul 09.
Article em En | MEDLINE | ID: mdl-38980197
ABSTRACT

INTRODUCTION:

This study aimed to assess the impact of positive-end-expiratory pressure (PEEP) on the non-hypoxic apnea time in infants during anesthesia induction with an inspired oxygen fraction of 0.8.

METHODS:

This age stratified randomized controlled trial included patients under 1 year of age. Preoxygenation was performed using an inspired oxygen fraction of 0.8 for 2 min. Inspired oxygen fraction of 0.8 was administered via a face mask with volume-controlled ventilation at a tidal volume of 6 mL.kg-1, with or without 7 cmH2O of PEEP. Tracheal intubation was performed after 3 min of ventilation; however, it was disconnected from the breathing circuit. Ventilation was resumed once the pulse oximetry readings reached 95%. The primary outcome was the non-hypoxic apnea time, defined as the time from the cessation of ventilation to achieving a pulse oximeter reading of 95%. The secondary outcome measures included the degree of atelectasis assessed by ultrasonography and the presence of gastric air insufflation.

RESULTS:

Eighty-four patients were included in the final analysis. In the positive end-expiratory pressure group, the atelectasis score decreased (17.0 vs. 31.5, p < .001; mean difference and 95% CI of 11.6, 7.5-15.6), while the non-hypoxic apnea time increased (80.1 s vs. 70.6 s, p = .005; mean difference and 95% CI of -9.4, -16.0 to -2.9), compared to the zero end-expiratory pressure group, among infants who are 6 months old or younger, not in those aged older than 6 months.

DISCUSSION:

The application of positive end-expiratory pressure reduced the incidence of atelectasis and extended the non-hypoxic apnea time in infants who are 6 months old or younger. However, it did not affect the incidence of atelectasis nor the non-hypoxic apnea time in patients aged older than 6 months.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article