Your browser doesn't support javascript.
loading
A Novel Diastolic Doppler Index Less Affected by Aortic Arch Anomalies Co-existing with Coarctation.
Ghorbannia, Arash; Spearman, Andrew D; Sawalhi, Shahd; Woods, Ronald K; Maadooliat, Mehdi; LaDisa, John F.
Afiliação
  • Ghorbannia A; Department of Biomedical Engineering, Marquette University and the Medical College of Wisconsin, Milwaukee, WI, USA. ghorbannia@outlook.com.
  • Spearman AD; Department of Pediatrics - Division of Cardiology, Herma Heart Institute, Children's Wisconsin and the Medical College of Wisconsin, 8701 W Watertown Plank Rd., Milwaukee, WI, 53226, USA. ghorbannia@outlook.com.
  • Sawalhi S; Department of Pediatrics - Division of Cardiology, Herma Heart Institute, Children's Wisconsin and the Medical College of Wisconsin, 8701 W Watertown Plank Rd., Milwaukee, WI, 53226, USA.
  • Woods RK; Department of Biomedical Engineering, Marquette University and the Medical College of Wisconsin, Milwaukee, WI, USA.
  • Maadooliat M; Division of Pediatric Cardiothoracic Surgery, Department of Surgery, Medical College of Wisconsin, Herma Heart Institute, Children's Wisconsin, Milwaukee, WI, USA.
  • LaDisa JF; Department of Mathematical and Statistical Sciences, Marquette University, Milwaukee, WI, USA.
Pediatr Cardiol ; 2024 Jul 12.
Article em En | MEDLINE | ID: mdl-38995425
ABSTRACT
Severity assessment for coarctation of the aorta (CoA) is challenging due to concomitant morphological anomalies (complex CoA) and inaccurate Doppler-based indices. Promising diagnostic performance has been reported for the continuous flow pressure gradient (CFPG), but it has not been studied in complex CoA. Our objective was to characterize the effect of complex CoA and associated hemodynamics on CFPG in a clinical cohort. Retrospective analysis identified discrete juxtaductal (n = 25) and complex CoA (n = 43; transverse arch and/or isthmus hypoplasia) patients with arm-leg systolic blood pressure gradients (BPG) within 24 h of echocardiography for comparison to BPG by conventional Doppler indices (simplified Bernoulli equation and modified forms correcting for proximal kinetic energy and/or recovered pressure). Results were interpreted using the current CoA guideline (BPG ≥ 20 mmHg) to compare diagnostic performance indicators including receiver operating characteristic curves, sensitivity, specificity, and diagnostic accuracy, among others. Echocardiography Z-scored aortic diameters were applied with computational simulations from a preclinical CoA model to understand aspects of the CFPG driving performance differences. Diagnostic performance was substantially reduced from discrete to complex CoA for conventional Doppler indices calculated from patient data, and by hypoplasia and/or long segment stenosis in simulations. In contrast, diagnostic indicators for the CFPG only modestly dropped for complex vs discrete CoA. Simulations revealed differences in performance due to inclusion of the Doppler velocity index and diastolic pressure half-time in the CFPG calculation. CFPG is less affected by aortic arch anomalies co-existing with CoA when compared to conventional Doppler indices.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article