Your browser doesn't support javascript.
loading
Urgent Candy-Plug technique for distal false lumen occlusion in chronic aortic dissection.
Eleshra, Ahmed; Kölbel, Tilo; Haulon, Stephan; Bertoglio, Luca; Rohlffs, Fiona; Dias, Nuno; Panuccio, Giuseppe; Tsilimparis, Nikolaos.
Afiliação
  • Eleshra A; Department of Vascular Surgery, German Aortic Center, University Heart & Vascular Center, University Medical Center Eppendorf, Hamburg, Germany; Department of Vascular Surgery, Faculty of Medicine, Mansoura University, Mansoura, Egypt. Electronic address: eleshraahmed@gmail.com.
  • Kölbel T; Department of Vascular Surgery, German Aortic Center, University Heart & Vascular Center, University Medical Center Eppendorf, Hamburg, Germany.
  • Haulon S; Department of Vascular Surgery, Hospital Marie Lannelongue, Paris, France.
  • Bertoglio L; Division of Vascular Surgery, Department of Sperimental and Clinical Sciences (DSCS), University and ASST Spedali Civili Hospital of Brescia, Brescia, Italy.
  • Rohlffs F; Department of Vascular Surgery, German Aortic Center, University Heart & Vascular Center, University Medical Center Eppendorf, Hamburg, Germany.
  • Dias N; Department of Vascular Surgery, Skåne University Hospital, Malmö, Sweden.
  • Panuccio G; Department of Vascular Surgery, German Aortic Center, University Heart & Vascular Center, University Medical Center Eppendorf, Hamburg, Germany.
  • Tsilimparis N; Department of Vascular Surgery, German Aortic Center, University Heart & Vascular Center, University Medical Center Eppendorf, Hamburg, Germany; Department of Vascular Surgery, University Hospital, LMU, Munich, Germany.
J Vasc Surg ; 2024 Jul 17.
Article em En | MEDLINE | ID: mdl-39029810
ABSTRACT

OBJECTIVE:

This study aimed to assess the impact of urgency on early and midterm outcomes of the Candy-Plug (CP) technique for distal false lumen (FL) occlusion in thoracic endovascular aortic repair for aortic dissection.

METHODS:

The CP registry was reviewed, and patients were categorized into elective and urgent/emergent groups for analysis. End points included technical success, clinical success, early (30-day) computed tomography angiography findings, early (30-day) mortality, adverse events, and aortic remodeling in patients with available computed tomography angiography follow-up and reintervention.

RESULTS:

A total of 155 patients received a custom-made CP, of whom 32 patients (44% male, mean age 61 ± 9 years) were treated urgently and 123 patients (63% male, mean age 62 ± 11 years) electively. The primary CP rate was higher in the urgent group (28/32, 88%, in the urgent group vs 96/123, 78%, in the elective group, P = .051). The mean contrast volume was higher in the urgent group (157 ± 56 mL in the urgent group vs 130 ± 71 mL in the elective group, P = .017). Technical success was achieved in all patients in both groups. Clinical success was achieved in 25 of 32 (78%) patients in the urgent group vs 113 and 123 (92%) in the elective group (P = .159). The early mortality rate was 13% (4 of 32 patients) in the urgent group vs 1% (1 of 123 patients) in the elective group (P = .120). There was no statistically significant difference regarding the early adverse events between the urgent and elective CP groups. Early aortic-related reinterventions were required in 6 of 32 (19%) patients in the urgent group vs 6 of 123 (5%) in the elective group (P = .094). Thoracic aortic aneurysm sac regression was lower in the urgent group (5/28, 18%, in the urgent group vs 63/114, 55%, in the elective group, P = .001). Stable thoracic aortic aneurysm sac was higher in the urgent group (22/28, 79%, in the urgent group vs 47/114, 41%, in the elective group, P = .000). An increase in thoracic aortic aneurysm sac occurred in 1 of 28 (4%) patients in the urgent group vs 4 of 114 (4%) patients in the elective group (P = .096).

CONCLUSIONS:

The urgent use of the CP technique for distal FL occlusion in aortic dissection was feasible and effective. The decrease in aortic FL sac diameter may be affected by the urgent use of CP due to limited sizing availability. However, it achieved a high rate of aortic remodeling.