Your browser doesn't support javascript.
loading
Immunological assay using a solid-state pore with a low limit of detection.
Takei, Hiroyasu; Nakada, Tomoko; Leong, Lat Wai; Ito, Atsuki; Hanada, Kakeru; Maeda, Hinako; Sohail, Muhammad Shan; Tomiyasu, Kazuhiko; Sakamoto, Osamu; Naono, Norihiko; Taniguchi, Masateru.
Afiliação
  • Takei H; Aipore Inc., 26-1 Sakuragaokacho, Shibuya, Tokyo, 150-8512, Japan.
  • Nakada T; SANKEN, Osaka University, 8-1 Mihogaoka, Ibaraki, Osaka, 567-0047, Japan.
  • Leong LW; SANKEN, Osaka University, 8-1 Mihogaoka, Ibaraki, Osaka, 567-0047, Japan.
  • Ito A; Aipore Inc., 26-1 Sakuragaokacho, Shibuya, Tokyo, 150-8512, Japan.
  • Hanada K; Aipore Inc., 26-1 Sakuragaokacho, Shibuya, Tokyo, 150-8512, Japan.
  • Maeda H; Aipore Inc., 26-1 Sakuragaokacho, Shibuya, Tokyo, 150-8512, Japan.
  • Sohail MS; Aipore Inc., 26-1 Sakuragaokacho, Shibuya, Tokyo, 150-8512, Japan.
  • Tomiyasu K; Aipore Inc., 26-1 Sakuragaokacho, Shibuya, Tokyo, 150-8512, Japan.
  • Sakamoto O; Aipore Inc., 26-1 Sakuragaokacho, Shibuya, Tokyo, 150-8512, Japan.
  • Naono N; Aipore Inc., 26-1 Sakuragaokacho, Shibuya, Tokyo, 150-8512, Japan.
  • Taniguchi M; SANKEN, Osaka University, 8-1 Mihogaoka, Ibaraki, Osaka, 567-0047, Japan. taniguti@sanken.osaka-u.ac.jp.
Sci Rep ; 14(1): 16686, 2024 07 19.
Article em En | MEDLINE | ID: mdl-39030274
ABSTRACT
Emerging infectious diseases, cancer, and other diseases are quickly tested mainly via immune reactions based on specific molecular recognition between antigens and antibodies. By changing the diameter of solid-state pores, biomolecules of various sizes can be rapidly detected at the single-molecule level. The combination of immunoreactions and solid-state pores paves the way for an efficient testing method with high specificity and sensitivity. The challenge in developing this method is achieving quantitative analysis using solid-state pores. Here, we demonstrate a method with a low limit of detection for testing tumor markers using a combination of immunoreactions and solid-state pore technology. Quantitative analysis of the mixing ratio of two and three beads with different diameters was achieved with an error rate of up to 4.7%. The hybrid solid-state pore and immunoreaction methods with prostate-specific antigen (PSA) and anti-PSA antibody-modified beads achieved a detection limit of 24.9 fM PSA in 30 min. The hybrid solid-state pore and immunoreaction enabled the rapid development of easy-to-use tests with lower limit of detection and greater throughput than commercially available immunoassay for point-of-care testing.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Antígeno Prostático Específico / Limite de Detecção Limite: Humans / Male Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Antígeno Prostático Específico / Limite de Detecção Limite: Humans / Male Idioma: En Ano de publicação: 2024 Tipo de documento: Article