Dynamic reconstruction for digital tomosynthesis: a phantom proof of concept for breast care.
Barbieri, Matteo; Jailin, Clément; Vancamberg, Laurence; Roux, Stéphane.
Afiliação
  • Barbieri M; GE HealthCare, Buc, France.
  • Jailin C; Université Paris-Saclay, CentraleSupélec, ENS Paris-Saclay, CNRS, LMPS-Laboratoire de Mécanique Paris-Saclay, Gif-sur-Yvette, France.
  • Vancamberg L; GE HealthCare, Buc, France.
  • Roux S; Université Paris-Saclay, CentraleSupélec, ENS Paris-Saclay, CNRS, LMPS-Laboratoire de Mécanique Paris-Saclay, Gif-sur-Yvette, France.
Biomed Phys Eng Express ; 10(5)2024 Aug 13.
Article em En | MEDLINE | ID: mdl-39053487
ABSTRACT
Objective. Digital tomosynthesis (DTS) is a type of limited-angle Computed Tomography (CT) used in orthopedic and oncology care to provide a pseudo-3D reconstructed volume of a body part from multiple x-ray projections. Patient motion during acquisitions results in artifacts which affect screening and diagnostic performances. Hence, accurate reconstruction of moving body parts from a tomosynthesis projection series is addressed in this paper, with a particular focus on the breast. The aim of this paper is to assess the feasibility of a novel dynamic reconstruction technique for DTS and evaluate its accuracy compared to an available ground truth.Approach. The proposed method is a combination of a 4D dynamic tomography strategy leveraging the formalism of Projection-based Digital Volume Correlation (P-DVC) with a multiscale approach to estimate and correct patient motion. Iterations of two operations are performed (i) a motion-corrected reconstruction based on the Simultaneous Iterative Reconstruction Technique (SIRT) algorithm and (ii) a motion estimation from projection residuals, to obtain motion-free volumes. Performance is evaluated on a synthetic Digital Breast Tomosynthesis (DBT) case. Three slabs of a CIRS breast phantom are imaged on a Senographe PristinaTM, under plate-wise rigid body motions with amplitudes ranging up to 10 mm so that an independent measurement of the motion can be accessed.Results. Results show a motion estimation average precision down to 0.183 mm (1.83 voxels), when compared to the independent measurement. Moreover, an 84.2% improvement on the mean residual error and a 59.9% improvement on the root mean square error (RMSE) with the original static reconstruction are obtained.Significance. Visual and quantitative assessments of the dynamically reconstructed volumes show that the proposed method fully restores conspicuity for important clinical features contained in the phantom.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Algoritmos / Processamento de Imagem Assistida por Computador / Mama / Neoplasias da Mama / Mamografia / Imagens de Fantasmas Limite: Female / Humans Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Algoritmos / Processamento de Imagem Assistida por Computador / Mama / Neoplasias da Mama / Mamografia / Imagens de Fantasmas Limite: Female / Humans Idioma: En Ano de publicação: 2024 Tipo de documento: Article