Your browser doesn't support javascript.
loading
Improvement of Breast Cancer Detection Using Dual-Layer Spectral CT.
Hasse, Felix Christian; Giannakis, Athanasios; Wehrse, Eckhard; Stiller, Wolfram; Wallwiener, Markus; Kauczor, Hans-Ulrich; Weber, Tim F; Heil, Jörg; Mokry, Theresa.
Afiliação
  • Hasse FC; Diagnostic and Interventional Radiology (DIR), Heidelberg University Hospital, Im Neuenheimer Feld 420, 69120 Heidelberg, Germany.
  • Giannakis A; Diagnostic and Interventional Radiology (DIR), Heidelberg University Hospital, Im Neuenheimer Feld 420, 69120 Heidelberg, Germany.
  • Wehrse E; Division of Radiology, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, 69120 Heidelberg, Germany.
  • Stiller W; Diagnostic and Interventional Radiology (DIR), Heidelberg University Hospital, Im Neuenheimer Feld 420, 69120 Heidelberg, Germany.
  • Wallwiener M; Department of Obstetrics and Gynecology, Heidelberg University Hospital, Im Neuenheimer Feld 440, 69120 Heidelberg, Germany.
  • Kauczor HU; Diagnostic and Interventional Radiology (DIR), Heidelberg University Hospital, Im Neuenheimer Feld 420, 69120 Heidelberg, Germany.
  • Weber TF; Diagnostic and Interventional Radiology (DIR), Heidelberg University Hospital, Im Neuenheimer Feld 420, 69120 Heidelberg, Germany.
  • Heil J; Heidelberg Breast Centre St. Elisabeth Clinic, Max-Reger-Straße 5, 69121 Heidelberg, Germany.
  • Mokry T; Diagnostic and Interventional Radiology (DIR), Heidelberg University Hospital, Im Neuenheimer Feld 420, 69120 Heidelberg, Germany.
Diagnostics (Basel) ; 14(14)2024 Jul 19.
Article em En | MEDLINE | ID: mdl-39061697
ABSTRACT
This study aimed to investigate the diagnostic performance of breast mass detection on monoenergetic image data at 40 keV (MonoE40) and on iodine maps (IM) compared with conventional image data (CI). In this prospective single-center case-control study, 50 breast cancer patients were examined using contrast-enhanced dual-layer spectral CT. For qualitative and quantitative comparison of MonoE40 and IM with CI image data, four blinded, independent readers assessed 300 randomized single slices (two slices for each imaging type per case) with or without cancerous lesions for the presence of a breast mass. Detection sensitivity and specificity were calculated and readers rated their subjective diagnostic certainty. For statistical analysis of sensitivity and specificity, a paired t-test and ANOVA were used (significance level p = 0.05). A total of 50 female patients (median age 51 years, range 28-83 years) participated. IM had the highest overall scores in sensitivity and specificity for breast cancer detection, with 0.97 ± 0.06 and 0.95 ± 0.07, respectively, compared with 0.90 ± 0.04 and 0.92 ± 0.06 in CI. MonoE40 yielded a sensitivity of 0.96 ± 0.02 and specificity of 0.94 ± 0.08. All differences in sensitivity and specificity between MonoE or IM and CI were statistically significant (p < 0.001). The superiority of IM sensitivity and specificity was most pronounced in patients with dense breasts. Spectral CT improved the detection of breast cancer with higher sensitivity and specificity compared to conventional image data in our study.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article