Hydroelectric Plant Safety: Real-Time Monitoring Utilizing Fiber-Optic Sensors.
Faraco, Renato Luiz; Barino, Felipe; Campos, Deivid; Sampaio, Guilherme; Honório, Leonardo; Marcato, André; Bessa Dos Santos, Alexandre; Dos Santos, Clayton Cesar; Hamaji, Fernando.
Afiliação
  • Faraco RL; Instrumentation and Telemetry Laboratory, Federal University of Juiz de Fora, Juiz de Fora 36036-900, Brazil.
  • Barino F; Instrumentation and Telemetry Laboratory, Federal University of Juiz de Fora, Juiz de Fora 36036-900, Brazil.
  • Campos D; Instrumentation and Telemetry Laboratory, Federal University of Juiz de Fora, Juiz de Fora 36036-900, Brazil.
  • Sampaio G; Instrumentation and Telemetry Laboratory, Federal University of Juiz de Fora, Juiz de Fora 36036-900, Brazil.
  • Honório L; Departamento de Energia Elétrica, Federal University of Juiz de Fora, Juiz de Fora 36036-900, Brazil.
  • Marcato A; Departamento de Energia Elétrica, Federal University of Juiz de Fora, Juiz de Fora 36036-900, Brazil.
  • Bessa Dos Santos A; Instrumentation and Telemetry Laboratory, Federal University of Juiz de Fora, Juiz de Fora 36036-900, Brazil.
  • Dos Santos CC; Santo Antônio Energia, Porto Velho 04548-001, Brazil.
  • Hamaji F; Santo Antônio Energia, Porto Velho 04548-001, Brazil.
Sensors (Basel) ; 24(14)2024 Jul 16.
Article em En | MEDLINE | ID: mdl-39065998
ABSTRACT
In the context of hydroelectric plants, this article emphasizes the imperative of robust monitoring strategies. The utilization of fiber-optic sensors (FOSs) emerges as a promising approach due to their efficient optical transmission, minimal signal attenuation, and resistance to electromagnetic interference. These optical sensors have demonstrated success in diverse structures, including bridges and nuclear plants, especially in challenging environments. This article culminates with the depiction of the development of an array of sensors featuring Fiber Bragg Gratings (FBGs). This array is designed to measure deformation and temperature in protective grids surrounding the turbines at the Santo Antônio Hydroelectric Plant. Implemented in a real-world scenario, the device identifies deformation peaks, indicative of water flow obstructions, thereby contributing significantly to the safety and operational efficiency of the plant.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article