Your browser doesn't support javascript.
loading
Relationships between biatrial substrate and recurrence after radiofrequency ablation in patients with persistent atrial fibrillation.
Lu, Yalin; Ma, Liang; Yang, Jian; Jin, Xinyang; Wang, Tao; Gao, Jing; Li, Yawen; Zhang, Ni; Yue, Qingxiong; Li, Shijun.
Afiliação
  • Lu Y; Department of Cardiology, Dalian Municipal Central Hospital, Dalian, China.
  • Ma L; China Medical University, Shenyang, China.
  • Yang J; Department of Cardiology, Dalian Municipal Central Hospital, Dalian, China.
  • Jin X; Department of Cardiology, Dalian Municipal Central Hospital, Dalian, China.
  • Wang T; Department of Cardiology, Dalian Municipal Central Hospital, Dalian, China.
  • Gao J; Dalian Medical University, Dalian, China.
  • Li Y; Department of Cardiology, Dalian Municipal Central Hospital, Dalian, China.
  • Zhang N; Department of Cardiology, Dalian Municipal Central Hospital, Dalian, China.
  • Yue Q; Dalian Medical University, Dalian, China.
  • Li S; Department of Cardiology, Dalian Municipal Central Hospital, Dalian, China.
Article em En | MEDLINE | ID: mdl-39105682
ABSTRACT

BACKGROUND:

Global longitudinal strain (GLS) and atrial voltage are acknowledged markers for worse rhythm outcome after ablation of persistent atrial fibrillation (PeAF). The majority of research efforts have been directed towards the left atrium (LA), with relatively fewer studies focusing on the right atrium (RA). The aim of this study was to investigate the effect of the biatrial substrate on the outcome following radiofrequency catheter ablation (RFCA).

METHODS:

All patients underwent two-dimensional speckle tracking echocardiography (2D-STE) and high-density mapping (HDM) on LA and RA in preoperative and postoperative stages of RFCA. Atrial substrate was assessed by GLS, average voltage, and low voltage zone (LVZ).

RESULTS:

This retrospective study enrolled 48 patients. With a follow-up of 385.98 ± 161.78 days, 22.92% (11/48) of all patients had AF recurrence and 63.64% in low strain group. Left atrial-low voltage zone (LA-LVZ) prior to RFCA was 67.52 ± 15.27% and 54.21 ± 20.07%, respectively, in the recurrence group and non-recurrence group. Multivariate regression analysis showed that preoperative LA-GLS (OR 0.047, 95%CI 0.002-0.941, p = .046) was independent predictors of AF recurrence. Biatrial average voltage in preoperative and postoperative stages were positively correlated (preoperative r = 0.563 p < .001; postoperative r = 0.464 p = .002). There was no significant difference in the proportion of RA in the recurrence group except the septum in preoperative and postoperative stages.

CONCLUSIONS:

Low LA-GLS and high LA-LVZ may be predictors of RFCA recurrence in PeAF patients. Biatrial average voltage were positively correlated in preoperative and postoperative stages.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article