Personalized optimization strategy for electrode array layout in TTFields of glioblastoma.
Wang, Liang; Chen, Chunxiao; Xiao, Yueyue; Gong, Rongfang; Shen, Jun; Lu, Ming.
Afiliação
  • Wang L; Department of Biomedical Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing, China.
  • Chen C; Department of Biomedical Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing, China.
  • Xiao Y; Department of Biomedical Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing, China.
  • Gong R; Department of Mathematics, Nanjing University of Aeronautics and Astronautics, Nanjing, China.
  • Shen J; Department of Mathematics, Nanjing University of Aeronautics and Astronautics, Nanjing, China.
  • Lu M; Department of Radiology, GuiQian International General Hospital, Guiyang, China.
Int J Numer Method Biomed Eng ; : e3859, 2024 Aug 18.
Article em En | MEDLINE | ID: mdl-39154656
ABSTRACT
Tumor treating fields (TTFields) is a novel therapeutic approach for the treatment of glioblastoma. The electric field intensity is a critical factor in the therapeutic efficacy of TTFields, as stronger electric field can more effectively impede the proliferation and survival of tumor cells. In this study, we aimed to improve the therapeutic effectiveness of TTFields by optimizing the position of electrode arrays, resulting in an increased electric field intensity at the tumor. Three representative head models of real glioblastoma patients were used as the research subjects in this study. The improved subtraction-average-based optimization (ISABO) algorithm based on circle chaos mapping, opposition-based learning and golden sine strategy, was employed to optimize the positions of the four sets of electrode arrays on the scalp. The electrode positions are dynamically adjusted through iterative search to maximize the electric field intensity at the tumor. The experimental results indicate that, in comparison to the conventional layout, the positions of the electrode arrays obtained by the ISABO algorithm can achieve average electric field intensity of 1.7887, 2.0058, and 1.3497 V/cm at the tumor of three glioblastoma patients, which are 23.6%, 29.4%, and 8.5% higher than the conventional layout, respectively. This study demonstrates that optimizing the location of the TTFields electrode array using the ISABO algorithm can effectively enhance the electric field intensity and treatment coverage in the tumor area, offering a more effective approach for personalized TTFields treatment.