Your browser doesn't support javascript.
loading
Investigations on the Performance of a Downhole Electric Heater with Different Parameters Used in Oil Shale In Situ Conversion.
Ren, Dazhong; Wang, Zhendong; Yang, Fu; Zeng, Hao; Zhang, Zengzeng.
Afiliação
  • Ren D; State Key Laboratory of Shale Oil and Gas Enrichment Mechanisms and Effective Development, Beijing 100083, China.
  • Wang Z; State Center for Research and Development of Oil Shale Exploitation, Beijing 100083, China.
  • Yang F; Shaanxi Key Laboratory of Advanced Stimulation Technology for Oil & Gas Reservoirs, Xi'an Shiyou University, Xi'an 710065, China.
  • Zeng H; Shaanxi Key Laboratory of Advanced Stimulation Technology for Oil & Gas Reservoirs, Xi'an Shiyou University, Xi'an 710065, China.
  • Zhang Z; Key Laboratory of Thermo-Fluid Science and Engineering, Ministry of Education, School of Energy and Power Engineering, Xi'an Jiaotong University, Xi'an 710049, China.
ACS Omega ; 9(33): 35600-35613, 2024 Aug 20.
Article em En | MEDLINE | ID: mdl-39184498
ABSTRACT
In situ conversion is the most potential technology for efficient and clean development of oil shale, and a downhole electric heater is key equipment for clean, efficient, and low-carbon in situ conversion. Three electric heating rods with different diameters are used to explore their influence on heater performances. The simulation results indicate that increasing the diameter of the heating rod helps to increase the minimum and maximum velocity of shell-side air, and the maximum velocity of H110-24 is 16.34 m/s, which is 1.25 and 1.13 times those of H110-16 and H110-20, respectively. In addition, the location of the local high temperature zone coincides with the area with low air flow velocity, and increasing the diameter of the heating rod can effectively reduce the heating rod surface temperature during high-power heating. Moreover, at the same heat flux, the heat transfer coefficients of H110-24 and H110-20 are 44.82-48.49% and 87.52-95.48% higher than those of H110-16, respectively. With the same heating power, the heat transfer coefficients of heaters have the same trend, indicating that the heat transfer coefficient of the heating rod can be effectively improved by increasing the diameter of the heating rod. Finally, the newly defined comprehensive performance is used to evaluate the heaters with different heating parameters. Increasing the heating power can improve the comprehensive performance of the heater, but the most effective way is to increase the diameter of the heating rod. With the same heating power, the new comprehensive performance of H110-24 and H110-20 is 48.38-52.34% and 87.29-95.19% higher than that of H110-16, respectively, and the electric heating rod with the diameter of 20 mm has the best performance.

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article