Your browser doesn't support javascript.
loading
Quantum Dot/TiO2 Nanocomposite-Based Photoelectrochemical Sensor for Enhanced H2O2 Detection Applied for Cell Monitoring and Visualization.
Zhao, Shuang; Yue, Zhao; Zhu, Dingcheng; Harberts, Jann; Blick, Robert H; Zierold, Robert; Lisdat, Fred; Parak, Wolfgang J.
Afiliação
  • Zhao S; Fachbereich Physik, CHyN, Universität Hamburg, Hamburg, 22761, Germany.
  • Yue Z; Key Laboratory for Special Fiber and Fiber Sensor of Hebei Province, School of Information Science and Engineering, Yanshan University, Qinhuangdao, 066004, China.
  • Zhu D; Department of Microelectronics, Nankai University, Tianjin, 30071, China.
  • Harberts J; Fachbereich Physik, CHyN, Universität Hamburg, Hamburg, 22761, Germany.
  • Blick RH; College of Material, Chemistry and Chemical Engineering, Key Laboratory of Organosilicon Chemistry and Material Technology, Ministry of Education, Hangzhou Normal University, Hangzhou, 311121, China.
  • Zierold R; Fachbereich Physik, CHyN, Universität Hamburg, Hamburg, 22761, Germany.
  • Lisdat F; Monash Institute of Pharmaceutical Sciences, Monash University, 381 Royal Parade, Parkville, 3052, VIC, Australia.
  • Parak WJ; Melbourne Centre for Nanofabrication, Victorian Node of the Australian National Fabrication Facility, 151 Wellington Road, Clayton, 3168, VIC, Australia.
Small ; : e2401703, 2024 Aug 29.
Article em En | MEDLINE | ID: mdl-39210661
ABSTRACT
This work exploits the possibility of using CdSe/ZnS quantum dot (QD)-electrodes to monitor the metabolism of living cells based on photoelectrochemical (PEC) measurements. To realize that, the PEC setup is improved with respect to an enhanced photocurrent signal, better stability, and an increased signal-to-noise ratio, but also for a better biocompatibility of the sensor surface on which cells have been grown. To achieve this, a QD-TiO2 heterojunction is introduced with the help of atomic layer deposition (ALD). The heterojunction reduces the charge carrier recombination inside the semiconductor nanoparticles and improves the drift behavior. The PEC performance is carefully analyzed by adjusting the TiO2 thickness and combining this strategy with multilayer immobilizations of QDs. The optimal thickness of this coating is ≈5 nm; here, photocurrent generation can be enhanced significantly (e.g., for a single QD layer electrode by more than one order of magnitude at 0 V vs Ag/AgCl). The resulting optimized electrode is used for hydrogen peroxide (H2O2) sensing with a good sensitivity down to µmolar concentrations, reusability, stability, response rate, and repeatability. Finally, the sensing system is applied to monitor the activity of cells directly grown on top of the electrode surface.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article