Your browser doesn't support javascript.
loading
The scoring system combined with radiomics and imaging features in predicting the malignant potential of incidental indeterminate small (<20 mm) solid pulmonary nodules.
Qu, Bai-Qiang; Wang, Yun; Pan, Yue-Peng; Cao, Pei-Wei; Deng, Xue-Ying.
Afiliação
  • Qu BQ; Department of Radiology, Wenling TCM Hospital Affiliated to Zhejiang Chinese Medical University, Taizhou, Zhejiang, 317500, China.
  • Wang Y; Department of Nuclear medicine, Zhejiang Cancer Hospital, Institute of Basic Medicine and Cancer (IBMC), Chinese Academy of Sciences, Hangzhou, Zhejiang, 310022, China.
  • Pan YP; Department of Radiology, Zhejiang Cancer Hospital, Institute of Basic Medicine and Cancer (IBMC), Chinese Academy of Sciences, Hangzhou, Zhejiang, 310022, China.
  • Cao PW; Department of Radiology, Zhejiang Cancer Hospital, Institute of Basic Medicine and Cancer (IBMC), Chinese Academy of Sciences, Hangzhou, Zhejiang, 310022, China.
  • Deng XY; Department of Radiology, Zhejiang Cancer Hospital, Institute of Basic Medicine and Cancer (IBMC), Chinese Academy of Sciences, Hangzhou, Zhejiang, 310022, China. a1145047838@163.com.
BMC Med Imaging ; 24(1): 234, 2024 Sep 06.
Article em En | MEDLINE | ID: mdl-39243018
ABSTRACT

OBJECTIVE:

Develop a practical scoring system based on radiomics and imaging features, for predicting the malignant potential of incidental indeterminate small solid pulmonary nodules (IISSPNs) smaller than 20 mm.

METHODS:

A total of 360 patients with malignant IISSPNs (n = 213) and benign IISSPNs (n = 147) confirmed after surgery were retrospectively analyzed. The whole cohort was randomly divided into training and validation groups at a ratio of 73. The least absolute shrinkage and selection operator (LASSO) algorithm was used to debase the dimensions of radiomics features. Multivariate logistic analysis was performed to establish models. The receiver operating characteristic (ROC) curve, area under the curve (AUC), 95% confidence interval (CI), sensitivity and specificity of each model were recorded. Scoring system based on odds ratio was developed.

RESULTS:

Three radiomics features were selected for further model establishment. After multivariate logistic analysis, the combined model including Mean, age, emphysema, lobulated and size, reached highest AUC of 0.877 (95%CI 0.830-0.915), accuracy rate of 83.3%, sensitivity of 85.3% and specificity of 80.2% in the training group, followed by radiomics model (AUC 0.804) and imaging model (AUC 0.773). A scoring system with a cutoff value greater than 4 points was developed. If the score was larger than 8 points, the possibility of diagnosing malignant IISSPNs could reach at least 92.7%.

CONCLUSION:

The combined model demonstrated good diagnostic performance in predicting the malignant potential of IISSPNs. A perfect accuracy rate of 100% can be achieved with a score exceeding 12 points in the user-friendly scoring system.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Tomografia Computadorizada por Raios X / Nódulo Pulmonar Solitário / Neoplasias Pulmonares Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Tomografia Computadorizada por Raios X / Nódulo Pulmonar Solitário / Neoplasias Pulmonares Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2024 Tipo de documento: Article