Management of Fluid Overload in Patients With Severe Aortic Stenosis (EASE-TAVR): A Randomized Controlled Trial.
JACC Cardiovasc Interv
; 17(17): 2054-2066, 2024 Sep 09.
Article
em En
| MEDLINE
| ID: mdl-39260962
ABSTRACT
BACKGROUND:
Fluid overload (FO) subjects patients with severe aortic stenosis (AS) to increased risk for heart failure and death after valve replacement and can be objectively quantified using bioimpedance spectroscopy (BIS).OBJECTIVES:
The authors hypothesized that in AS patients with concomitant FO, BIS-guided decongestion could improve prognosis and quality of life following transcatheter aortic valve replacement (TAVR).METHODS:
This randomized, controlled trial enrolled 232 patients with severe AS scheduled for TAVR. FO was defined using a portable whole-body BIS device according to previously established cutoffs (≥1.0 L and/or ≥7%). Patients with FO (n = 111) were randomly assigned 11 to receive BIS-guided decongestion (n = 55) or decongestion by clinical judgment alone (n = 56) following TAVR. Patients without FO (n = 121) served as a control cohort. The primary endpoint was the composite of hospitalization for heart failure and/or all-cause death at 12 months. The secondary endpoint was the change from baseline to 12 months in the Kansas City Cardiomyopathy Questionnaire.RESULTS:
The occurrence of the primary endpoint at 12 months was significantly lower in the BIS-guided vs the non-BIS-guided decongestion group (7/55 [12.7%, all deaths] vs 18/56 [32.1%, 9 hospitalizations for heart failure and 9 deaths]; HR 0.36; 95% CI 0.15-0.87; absolute risk reduction = -19.4%). Outcomes in the BIS-guided decongestion group were identical to the euvolemic control group (log-rank test, P = 0.7). BIS-guided decongestion was also associated with a higher increase in the Kansas City Cardiomyopathy Questionnaire score from baseline compared to non-BIS-guided decongestion (P = 0.001).CONCLUSIONS:
In patients with severe AS and concomitant FO, quantitatively guided decongestive treatment and associated intensified management post-TAVR was associated with improved outcomes and quality of life compared to decongestion by clinical judgment alone. (Management of Fluid Overload in Patients Scheduled for Transcatheter Aortic Valve Replacement [EASE-TAVR]; NCT04556123).Palavras-chave
Texto completo:
1
Base de dados:
MEDLINE
Assunto principal:
Estenose da Valva Aórtica
/
Qualidade de Vida
/
Índice de Gravidade de Doença
/
Substituição da Valva Aórtica Transcateter
/
Insuficiência Cardíaca
Limite:
Aged80
Idioma:
En
Ano de publicação:
2024
Tipo de documento:
Article