Your browser doesn't support javascript.
loading
Comparison of four aortic bioprostheses: Hancock II vs. St Jude Trifecta vs. Carpentier-Edwards Perimount Magna vs. Magna Ease-mid-term results (COMPARE SAVR study).
Bajorek, Natalia; Filip, Grzegorz; Malinowski, Krzysztof; Kedziora, Anna; Mazur, Piotr; Ramaprabhu, Krithika; Bartus, Krzysztof; Batko, Jakub; Rams, Daniel J; Deja, Marek; Widenka, Kazimierz; Tobota, Zdzislaw; Maruszewski, Bohdan J; Burysz, Marian; Litwinowicz, Radoslaw.
Afiliação
  • Bajorek N; Department of Medical Education, Center for Innovative Medical Education, Jagiellonian University Medical College, Krakow, Poland.
  • Filip G; Department of Cardiac and Vascular Diseases, John Paul II Hospital, Krakow, Poland.
  • Malinowski K; Department of Cardiovascular Surgery and Transplantology, John Paul II Hospital, Krakow, Poland.
  • Kedziora A; Institute of Cardiology, Jagiellonian University Medical College, Krakow, Poland.
  • Mazur P; Department of Cardiovascular Surgery and Transplantology, John Paul II Hospital, Krakow, Poland.
  • Ramaprabhu K; Institute of Cardiology, Jagiellonian University Medical College, Krakow, Poland.
  • Bartus K; Institute of Cardiology, Jagiellonian University Medical College, Krakow, Poland.
  • Batko J; Department of Cardiovascular Surgery, Mayo Clinic, Rochester, MN, USA.
  • Rams DJ; Department of Cardiovascular Surgery, Mayo Clinic, Rochester, MN, USA.
  • Deja M; Department of Cardiovascular Surgery and Transplantology, John Paul II Hospital, Krakow, Poland.
  • Widenka K; Institute of Cardiology, Jagiellonian University Medical College, Krakow, Poland.
  • Tobota Z; CAROL-Cardiothoracic Anatomy Research Operative Lab, Department of Cardiovascular Surgery and Transplantology, Institute of Cardiology, Jagiellonian University Medical College, Krakow, Poland.
  • Maruszewski BJ; CAROL-Cardiothoracic Anatomy Research Operative Lab, Department of Cardiovascular Surgery and Transplantology, Institute of Cardiology, Jagiellonian University Medical College, Krakow, Poland.
  • Burysz M; Department of Cardiac Surgery, Faculty of Medical Sciences in Katowice, Medical University of Silesia, Katowice, Poland.
  • Litwinowicz R; Clinical Department of Cardiac Surgery, District Hospital No. 2, University of Rzeszów, Rzeszów, Poland.
J Thorac Dis ; 16(8): 5018-5030, 2024 Aug 31.
Article em En | MEDLINE | ID: mdl-39268099
ABSTRACT

Background:

In the era of percutaneous aortic valve implantation, biological valves are the preferred prostheses implanted in patients undergoing surgical aortic valve replacement (sAVR). The aim was to present a real-life analysis of mid-term sAVR outcomes for the four aortic bioprostheses the Hancock II, the Carpentier-Edwards Perimount Magna, the Carpentier-Edwards Perimount Magna Ease and the Trifecta valve.

Methods:

This is a retrospective study based on data from the Polish National Cardiac Surgery Database. The study population comprised of 1,589 consecutive patients, of whom 432 were in the Hancock II group, 356 in the Carpentier-Edwards Perimount Magna group, 427 in the Carpentier-Edwards Magna Ease group, and 374 in the Trifecta group. A comparison of the four groups was performed using analysis of variance (ANOVA) or Kruskal-Wallis test with appropriate post hoc tests (Tukey HSD or Steel-Dwass, respectively).

Results:

Patients in the Hancock II group were older, had higher New York Heart Association (NYHA) and Canadian Cardiovascular Society (CCS) classes, had lower prevalence of hypertension and hyperlipidemia but higher prevalence of diabetes. The lowest mean valve size was observed in Trifecta group and the highest was in the Magna group (P<0.001). Survival analysis showed no significant differences in in-hospital mortality 3.9% in Hancock II, 3.1% in Perimount, 3.3% in Magna and 2.1% in Trifecta group. Five-year mortality was significantly higher in Hancock II group (25.7%) compared to the other bioprostheses 12.1% in Perimount, 9.1% in Magna and 10.70% in Trifecta group respectively.

Conclusions:

The 5-year mortality rate was significantly higher in the Hancock II group compared to the other bioprostheses. In contrast, Trifecta, Perimount Magna, and Magna Ease had similar 5-year mortality rates.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article