Variable-cut particle-size classification by opposing jets.
Am Ind Hyg Assoc J ; 39(12): 952-7, 1978 Dec.
Article em En | MEDLINE | ID: mdl-742597
ABSTRACT
A new technique of aerodynamic particle-size classification has been developed utilizing axisymmetrically-opposed air jets. For a fixed geometry the cut size can be varied from 0.8 to 3.6 micrometer by changing the jet flow rates. Future designs are expected to extend the useful particle-size range. Particles remain airborne after size separation, permitting the use of continuous, automated methods for analyzing the particle concentration and chemical compositon.