Preoperative diagnostic accuracy of fine-needle aspiration in the management of breast lesions: comparison of specificity and sensitivity with clinical examination, mammography, echography, and thermography in 249 patients.
Diagn Cytopathol
; 11(1): 4-8, 1994.
Article
em En
| MEDLINE
| ID: mdl-7956659
Two hundred and forty-nine women suffering from breast problems underwent a complete series of tests including clinical examination, mammography, echography, thermography, and fine-needle aspiration (FNA). Ninety-four of these patients were shown to be positive or to have suspected malignancy. Accordingly, they underwent surgical excision followed by histologic examination, while the remaining patients were re-examined after 12 to 18 mo in order to exclude false negatives. The analysis of specificity and sensitivity of every single procedure showed that FNA describes the best degree of sensitivity and specificity but no procedure allows, by itself, the detection of all carcinomas. When considered in combination, clinical examination, mammography, and fine-needle aspiration have a sensitivity of 100% and a specificity of 49%, and are the best diagnostic tests for a correct assessment of mammary lesions. Thermography and echography showed a low degree of sensitivity and should not be included in the routine diagnostic procedure of breast lesions.
Buscar no Google
Base de dados:
MEDLINE
Assunto principal:
Biópsia por Agulha
/
Neoplasias da Mama
Tipo de estudo:
Diagnostic_studies
Limite:
Female
/
Humans
Idioma:
En
Ano de publicação:
1994
Tipo de documento:
Article