ABSTRACT
We describe 37 patients in whom 52 self-expandable metallic stents were successfully placed using a flexible bronchoscope. Indications for stenting were tracheobronchomalacia (n=13), neoplasia (n=20), and tracheal stenosis (n=4). Airway patency was restored in all patients. Symptoms improved in all but one patient. The median follow-up for all patients and the group of 16 patients alive has been 21 and 69.5 weeks, respectively. Complications have included granulomas and bronchitis. Migration or mucus plugging was not encountered. We conclude that metallic stents can be inserted safely using a flexible bronchoscope. At least in the short term, major complications are uncommon.
Assuntos
Buscar no Google
Base de dados: MEDLINE Assunto principal: Brônquios / Broncoscopia / Stents Tipo de estudo: Etiology_studies / Observational_studies / Prognostic_studies Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 1998 Tipo de documento: Article
Buscar no Google
Base de dados: MEDLINE Assunto principal: Brônquios / Broncoscopia / Stents Tipo de estudo: Etiology_studies / Observational_studies / Prognostic_studies Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 1998 Tipo de documento: Article