Your browser doesn't support javascript.
loading
Balloon angioplasty for the treatment of coronary in-stent restenosis: immediate results and 6-month angiographic recurrent restenosis rate.
Eltchaninoff, H; Koning, R; Tron, C; Gupta, V; Cribier, A.
Afiliação
  • Eltchaninoff H; Department of Cardiology, Hôpital Charles Nicolle, University of Rouen, France.
J Am Coll Cardiol ; 32(4): 980-4, 1998 Oct.
Article em En | MEDLINE | ID: mdl-9768721
ABSTRACT

OBJECTIVES:

The purpose of this prospective study was to evaluate the immediate results and the 6-month angiographic recurrent restenosis rate after balloon angioplasty for in-stent restenosis.

BACKGROUND:

Despite excellent immediate and mid-term results, 20% to 30% of patients with coronary stent implantation will present an angiographic restenosis and may require additional treatment. The optimal treatment for in-stent restenosis is still unclear.

METHODS:

Quantitative coronary angiography (QCA) analyses were performed before and after stent implantation, before and after balloon angioplasty for in-stent restenosis and on a 6-month systematic coronary angiogram to assess the recurrent angiographic restenosis rate.

RESULTS:

Balloon angioplasty was performed in 52 patients presenting in-stent restenosis. In-stent restenosis was either diffuse (> or =10 mm) inside the stent (71%) or focal (29%). Mean stent length was 16+/-7 mm. Balloon diameter of 2.98+/-0.37 mm and maximal inflation pressure of 10+/-3 atm were used for balloon angioplasty. Angiographic success rate was 100% without any complication. Acute gain was lower after balloon angioplasty for in-stent restenosis than after stent implantation 1.19+/-0.60 mm vs. 1.75+/-0.68 mm (p=0.0002). At 6-month follow-up, 60% of patients were asymptomatic and no patient died. Eighteen patients (35%) had repeat target vessel revascularization. Angiographic restenosis rate was 54%. Recurrent restenosis rate was higher when in-stent restenosis was diffuse 63% vs. 31% when focal, p=0.046.

CONCLUSIONS:

Although balloon angioplasty for in-stent restenosis can be safely and successfully performed, it leads to less immediate stenosis improvement than at time of stent implantation and carries a high recurrent angiographic restenosis rate at 6 months, in particular in diffuse in-stent restenosis lesions.
Assuntos
Buscar no Google
Base de dados: MEDLINE Assunto principal: Angioplastia Coronária com Balão / Stents / Angiografia Coronária / Doença das Coronárias / Vasos Coronários Tipo de estudo: Observational_studies / Prognostic_studies Limite: Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 1998 Tipo de documento: Article
Buscar no Google
Base de dados: MEDLINE Assunto principal: Angioplastia Coronária com Balão / Stents / Angiografia Coronária / Doença das Coronárias / Vasos Coronários Tipo de estudo: Observational_studies / Prognostic_studies Limite: Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 1998 Tipo de documento: Article