The Usefulness of CO2 Laser-Assisted Phonomicrosurgery Using a Computer-Guided Scanner in Broad-Based Vocal Polyp / 대한이비인후과학회지
Korean Journal of Otolaryngology - Head and Neck Surgery
; : 511-515, 2013.
Article
em Ko
| WPRIM
| ID: wpr-656504
Biblioteca responsável:
WPRO
ABSTRACT
BACKGROUND AND OBJECTIVES:
New computer-guided scanner (CGS) recently applied to CO2 laser micromanipulator allows the beam to sweep a given surface with extreme rapidity. Our aim in this study is to evaluate the efficacy and usefulness of CO2 laser-assisted phonomicrosurgery using a CGS in broad-based vocal polyp. SUBJECTS ANDMETHOD:
The current study enrolled 41 patients who underwent phonomicrosurgery for broad base polyp of vocal fold. Twenty patients underwent CO2 laser-assisted phonomicrosurgery using CGS (Group 1), and 21 patients underwent conventional phonomicrosurgery using cold instruments (Group 2).RESULTS:
All voice analysis parameters showed significant improvement after surgical treatment, except fundamental frequency and noise-to-harmonic ratio. Differences between preoperative and postoperative parameters of each voice analysis data did not differ significantly between the two groups.CONCLUSION:
Although no significant difference was observed between the two groups, CO2 laser-assisted phonomicrosurgery using CGS allow for performance of more accurate and delicate incision with a controllable depth of beam penetration.Palavras-chave
Texto completo:
1
Base de dados:
WPRIM
Assunto principal:
Pólipos
/
Prega Vocal
/
Voz
/
Criocirurgia
/
Lasers de Gás
Limite:
Humans
Idioma:
Ko
Ano de publicação:
2013
Tipo de documento:
Article