Objective To investigate the safety and efficiency of China-made stent in patients with acute myocardial infarction(AMI).Methods Thirty-six patients with AMI were enrolled in our study,with mean age(57?9.7)years old.China-made stent were implanted successfully.Eighteen patients had acute anterior myocardial infarction,14 had acute inferior myocardial infarction,2 had acute lateral myocardial infarction,2 had acute posterior accompanied with right ventricular myocardial infarction.There were 12 patients with diabetes,20 patients with hypertension,18 patients with smoking.Results Thirty-seven China-made stents were implanted in the 36 patients.There were no complications during the procedure.All have acquired TIMI 3 flow.There were no thrombosis in the stent in 20 patients at the 7-day following up.Conclusion It is safe and efficient with the China-made stent implanted in patients with acute myocardial infarction.