PURPOSE: To investigate the effects of cataract grade based on wide-field fundus imaging on macular thickness measured by spectral domain optical coherence tomography (SD-OCT) and its signal-to-noise ratio (SNR). METHODS: Two hundred cataract patients (200 eyes) with preoperative measurements by wide-field fundus imaging and macular SD-OCT were enrolled. Cataract severity was graded from 1 to 4 according to the degree of macular obscuring by cataract artifact in fundus photo images. Cataract grade based on wide-field fundus image, the Lens Opacity Classification System III, macular thickness, and SD-OCT SNR were compared. All SD-OCT B-scan images were evaluated to detect errors in retinal layer segmentation. RESULTS: Cataract grade based on wide-field fundus imaging was positively correlated with grade of posterior subcapsular cataracts (rho = 0.486, p < 0.001), but not with nuclear opalescence or cortical cataract using the Lens Opacity Classification System III. Cataract grade was negatively correlated with total macular thickness (rho = −0.509, p < 0.001) and SD-OCT SNR (rho = −0.568, p < 0.001). SD-OCT SNR was positively correlated with total macular thickness (rho = 0.571, p < 0.001). Of 200 eyes, 97 (48.5%) had segmentation errors on SD-OCT. As cataract grade increased and SD-OCT SNR decreased, the percentage of eyes with segmentation errors on SD-OCT increased. All measurements of macular thickness in eyes without segmentation errors were significantly greater than those of eyes with segmentation errors. CONCLUSIONS: Posterior subcapsular cataracts had profound effects on cataract grade based on wide-field fundus imaging. As cataract grade based on wide-field fundus image increased, macular thickness tended to be underestimated due to segmentation errors in SD-OCT images. Segmentation errors in SD-OCT should be considered when evaluating macular thickness in eyes with cataracts.
Assuntos
Palavras-chave
Texto completo: 1 Base de dados: WPRIM Assunto principal: Retinaldeído / Catarata / Classificação / Artefatos / Tomografia de Coerência Óptica / Razão Sinal-Ruído / Iridescência / Fundo de Olho Limite: Humans Idioma: En Ano de publicação: 2018 Tipo de documento: Article
Texto completo: 1 Base de dados: WPRIM Assunto principal: Retinaldeído / Catarata / Classificação / Artefatos / Tomografia de Coerência Óptica / Razão Sinal-Ruído / Iridescência / Fundo de Olho Limite: Humans Idioma: En Ano de publicação: 2018 Tipo de documento: Article