Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Proc Inst Mech Eng H ; 227(1): 3-17, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23516951

RESUMO

This study aimed to develop a three-dimensional finite element model of a functionally graded femoral prosthesis. The model consisted of a femoral prosthesis created from functionally graded materials (FGMs), cement, and femur. The hip prosthesis was composed of FGMs made of titanium alloy, chrome-cobalt, and hydroxyapatite at volume fraction gradient exponents of 0, 1, and 5, respectively. The stress was measured on the femoral prosthesis, cement, and femur. Stress on the neck of the femoral prosthesis was not sensitive to the properties of the constituent material. However, stress on the stem and cement decreased proportionally as the volume fraction gradient exponent of the FGM increased. Meanwhile, stress became uniform on the cement mantle layer. In addition, stress on the femur in the proximal part increased and a high surface area of the femoral part was involved in absorbing the stress. As such, the stress-shielding area decreased. The results obtained in this study are significant in the design and longevity of new prosthetic devices because FGMs offer the potential to achieve stress distribution that more closely resembles that of the natural bone in the femur.


Assuntos
Materiais Biocompatíveis/química , Fêmur/fisiologia , Fêmur/cirurgia , Prótese de Quadril , Modelos Biológicos , Suporte de Carga/fisiologia , Simulação por Computador , Desenho Assistido por Computador , Módulo de Elasticidade/fisiologia , Análise de Falha de Equipamento , Análise de Elementos Finitos , Humanos , Desenho de Prótese , Resistência à Tração
2.
Clin Biomech (Bristol, Avon) ; 27(1): 34-9, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-21794965

RESUMO

BACKGROUND: The method of attachment of prosthesis to the residual limb (suspension) and socket fitting is a critical issue in the process of providing an amputee with prosthesis. Different suspension methods try to minimize the pistoning movement inside the socket. The Seal-In(®) X5 and Dermo(®) Liner by Ossur are new suspension liners that intend to reduce pistoning between the socket and liner. Since the effects of these new liners on suspension are unclear, the objective of this study was to compare the pistoning effect of Seal-In(®) X5 and Dermo(®) Liner by using Vicon Motion System. METHODS: Six transtibial amputees, using both the Iceross Seal-In(®) X5 and the Iceross Dermo(®) Liner, participated in the study. The vertical displacement (pistoning) was measured between the liner and socket in single limb support on the prosthetic limb (full-weight bearing), double limb support (semi-weight bearing), and non-weight bearing on the prosthetic limb, and also under three static vertical loading conditions (30 N, 60 N, and 90 N). FINDINGS: The results demonstrated that the pistoning within the socket when Seal-In(®) X5 was used, decreased by 71% in comparison to the Iceross Dermo(®) Liner. In addition, a significant difference between the two liners under different static conditions was found (p<0.05). INTERPRETATION: Participants needed to put in extra effort for donning and doffing the prosthesis with Seal-In(®) X5; however, this type of liner provided less pistoning. The new approach that uses the motion analysis system in this study might be an alternative for measuring the pistoning effect in the prosthetic socket.


Assuntos
Cotos de Amputação/fisiopatologia , Amputados/reabilitação , Membros Artificiais , Equilíbrio Postural , Tíbia/fisiopatologia , Suporte de Carga , Adulto , Idoso , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Masculino , Pessoa de Meia-Idade , Ajuste de Prótese/métodos , Estresse Mecânico , Resultado do Tratamento , Adulto Jovem
3.
Med Eng Phys ; 33(4): 407-10, 2011 May.
Artigo em Inglês | MEDLINE | ID: mdl-21146440

RESUMO

The investigation of patellar tendon reflex involves development of a reflex hammer holder, kinematic data collection and analysis of patellar reflex responses using motion analysis techniques. The main aim of this research is to explore alternative means of assessing reflexes as a part of routine clinical diagnosis. The motion analysis system was applied to provide quantitative data which is a more objective measure of the patellar tendon reflex. Kinematic data was collected from 28 males and 22 females whilst subjected to a knee jerk test. Further analysis of kinematic data was performed to predict relationships which might affect the patellar tendon reflex. All subjects were seated on a high stool with their legs hanging freely within the capture volume of the motion analysis system. Knee jerk tests were applied to all subjects, on both sides of the leg, by eliciting hypo, hyper, and normal reflexes. An additional reinforcement technique called the Jendrassik manoeuvre was also performed under the same conditions to elicit a normal patellar tendon reflex. The comparison of reflex response between genders showed that female subjects generally had a greater response compared to males. However, the difference in reflex response between the left leg and the right leg was not significant. Tapping strength to elicit a hyper-reflex produced greater knee-jerk compared to the normal clinical tapping strength. All results were in agreement with clinical findings and results found by some early researchers.


Assuntos
Movimento/fisiologia , Ligamento Patelar/fisiologia , Reflexo/fisiologia , Feminino , Humanos , Masculino , Fenômenos Mecânicos , Caracteres Sexuais , Adulto Jovem
4.
Acta Bioeng Biomech ; 11(4): 37-43, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-20405814

RESUMO

Conventionally, patellar tendon-bearing (PTB) sockets, which need high dexterity of prosthetist, are widely used. Lack of chartered and experienced prosthetist has often led to painful experience of wearing prosthesis and this will in turn deter the patients to wear the prosthesis, which will further aggravate stump shrinkage. Thus, the hydrostatic socket which demands relatively lower level of fabricating skill is proposed to replace the PTB socket in order to produce the equivalent, if not better, quality of support to the amputee patients. Both sockets' pressure profiles are studied and compared using finite element analysis (FEA) software. Three-dimensional models of both sockets were developed using MIMICS software. The analysis results showed that hydrostatic socket did exhibit more uniform pressure profiles than that of PTB socket. PTB socket showed pressure concentration near the proximal brim of the socket and also at the distal fibula. It was also found that the pressure magnitude in hydrostatic socket is relatively lower than that of PTB socket.


Assuntos
Ligamento Patelar/fisiopatologia , Cotos de Amputação/fisiopatologia , Cotos de Amputação/cirurgia , Amputados/reabilitação , Membros Artificiais , Fenômenos Biomecânicos , Análise de Elementos Finitos , Humanos , Pressão Hidrostática , Malásia , Modelos Biológicos , Ligamento Patelar/cirurgia , Suporte de Carga/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA