Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 28
Filtrar
1.
Sensors (Basel) ; 20(22)2020 Nov 10.
Artigo em Inglês | MEDLINE | ID: mdl-33182658

RESUMO

Spatiotemporal parameters of gait serve as an important biomarker to monitor gait impairments as well as to develop rehabilitation systems. In this work, we developed a computationally-efficient algorithm (SDI-Step) that uses segmented double integration to calculate step length and step time from wearable inertial measurement units (IMUs) and assessed its ability to reliably and accurately measure spatiotemporal gait parameters. Two data sets that included simultaneous measurements from wearable sensors and from a laboratory-based system were used in the assessment. The first data set utilized IMU sensors and a GAITRite mat in our laboratory to monitor gait in fifteen participants: 9 young adults (YA1) (5 females, 4 males, age 23.6 ± 1 years), and 6 people with Parkinson's disease (PD) (3 females, 3 males, age 72.3 ± 6.6 years). The second data set, which was accessed from a publicly-available repository, utilized IMU sensors and an optoelectronic system to monitor gait in five young adults (YA2) (2 females, 3 males, age 30.5 ± 3.5 years). In order to provide a complete representation of validity, we used multiple statistical analyses with overlapping metrics. Gait parameters such as step time and step length were calculated and the agreement between the two measurement systems for each gait parameter was assessed using Passing-Bablok (PB) regression analysis and calculation of the Intra-class Correlation Coefficient (ICC (2,1)) with 95% confidence intervals for a single measure, absolute-agreement, 2-way mixed-effects model. In addition, Bland-Altman (BA) plots were used to visually inspect the measurement agreement. The values of the PB regression slope were close to 1 and intercept close to 0 for both step time and step length measures. The results obtained using ICC (2,1) for step length showed a moderate to excellent agreement for YA (between 0.81 and 0.95) and excellent agreement for PD (between 0.93 and 0.98), while both YA and PD had an excellent agreement in step time ICCs (>0.9). Finally, examining the BA plots showed that the measurement difference was within the limits of agreement (LoA) with a 95% probability. Results from this preliminary study indicate that using the SDI-Step algorithm to process signals from wearable IMUs provides measurements that are in close agreement with widely-used laboratory-based systems and can be considered as a valid tool for measuring spatiotemporal gait parameters.


Assuntos
Análise da Marcha/instrumentação , Doença de Parkinson/reabilitação , Dispositivos Eletrônicos Vestíveis , Adulto , Idoso , Algoritmos , Feminino , Humanos , Masculino , Doença de Parkinson/diagnóstico , Reprodutibilidade dos Testes , Adulto Jovem
2.
Sensors (Basel) ; 19(24)2019 Dec 11.
Artigo em Inglês | MEDLINE | ID: mdl-31835870

RESUMO

Progressive gait dysfunction is one of the primary motor symptoms in people with Parkinson's disease (PD). It is generally expressed as reduced step length and gait speed and as increased variability in step time and step length. People with PD also exhibit stooped posture which disrupts gait and impedes social interaction. The gait and posture impairments are usually resistant to the pharmacological treatment, worsen as the disease progresses, increase the likelihood of falls, and result in higher rates of hospitalization and mortality. These impairments may be caused by perceptual deficiencies (poor spatial awareness and loss of temporal rhythmicity) due to the disruptions in processing intrinsic information related to movement initiation and execution which can result in misperceptions of the actual effort required to perform a desired movement and maintain a stable posture. Consequently, people with PD often depend on external cues during execution of motor tasks. Numerous studies involving open-loop cues have shown improvements in gait and freezing of gait (FoG) in people with PD. However, the benefits of cueing may be limited, since cues are provided in a consistent/rhythmic manner irrespective of how well a person follows them. This limitation can be addressed by providing feedback in real-time to the user about performance (closed-loop cueing) which may help to improve movement patterns. Some studies that used closed-loop cueing observed improvements in gait and posture in PD, but the treadmill-based setup in a laboratory would not be accessible outside of a research setting, and the skills learned may not readily and completely transfer to overground locomotion in the community. Technologies suitable for cueing outside of laboratory environments could facilitate movement practice during daily activities at home or in the community and could strongly reinforce movement patterns and improve clinical outcomes. This narrative review presents an overview of cueing paradigms that have been utilized to improve gait and posture in people with PD and recommends development of closed-loop wearable systems that can be used at home or in the community to improve gait and posture in PD.


Assuntos
Transtornos Neurológicos da Marcha/fisiopatologia , Marcha/fisiologia , Doença de Parkinson/fisiopatologia , Postura/fisiologia , Idoso , Cognição/fisiologia , Transtornos Neurológicos da Marcha/reabilitação , Humanos , Doença de Parkinson/reabilitação
3.
J Neurophysiol ; 113(7): 2666-75, 2015 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-25673734

RESUMO

Spinal cord injury (SCI) can lead to changes in muscle activation patterns and atrophy of affected muscles. Moderate levels of SCI are typically associated with foot drag during the swing phase of locomotion. Foot drag is often used to assess locomotor recovery, but the causes remain unclear. We hypothesized that foot drag results from inappropriate muscle coordination preventing flexion at the stance-to-swing transition. To test this hypothesis and to assess the relative contributions of neural and muscular changes on foot drag, we developed a two-dimensional, one degree of freedom ankle musculoskeletal model with gastrocnemius and tibialis anterior muscles. Anatomical data collected from sham-injured and incomplete SCI (iSCI) female Long-Evans rats as well as physiological data from the literature were used to implement an open-loop muscle dynamics model. Muscle insertion point motion was calculated with imposed ankle trajectories from kinematic analysis of treadmill walking in sham-injured and iSCI animals. Relative gastrocnemius deactivation and tibialis anterior activation onset times were varied within physiologically relevant ranges based on simplified locomotor electromyogram profiles. No-atrophy and moderate muscle atrophy as well as normal and injured muscle activation profiles were also simulated. Positive moments coinciding with the transition from stance to swing phase were defined as foot swing and negative moments as foot drag. Whereas decreases in activation delay caused by delayed gastrocnemius deactivation promote foot drag, all other changes associated with iSCI facilitate foot swing. Our results suggest that even small changes in the ability to precisely deactivate the gastrocnemius could result in foot drag after iSCI.


Assuntos
Tornozelo/fisiopatologia , Transtornos Neurológicos da Marcha/fisiopatologia , Modelos Biológicos , Contração Muscular , Músculo Esquelético/fisiopatologia , Traumatismos da Medula Espinal/fisiopatologia , Adaptação Fisiológica , Animais , Simulação por Computador , Feminino , Marcha , Transtornos Neurológicos da Marcha/etiologia , Atrofia Muscular/etiologia , Atrofia Muscular/fisiopatologia , Ratos , Ratos Long-Evans , Traumatismos da Medula Espinal/complicações
4.
J Neuroeng Rehabil ; 10: 97, 2013 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-23947694

RESUMO

BACKGROUND: Following incomplete spinal cord injury (iSCI), descending drive is impaired, possibly leading to a decrease in the complexity of gait. To test the hypothesis that iSCI impairs gait coordination and decreases locomotor complexity, we collected 3D joint angle kinematics and muscle parameters of rats with a sham or an incomplete spinal cord injury. METHODS: 12 adult, female, Long-Evans rats, 6 sham and 6 mild-moderate T8 iSCI, were tested 4 weeks following injury. The Basso Beattie Bresnahan locomotor score was used to verify injury severity. Animals had reflective markers placed on the bony prominences of their limb joints and were filmed in 3D while walking on a treadmill. Joint angles and segment motion were analyzed quantitatively, and complexity of joint angle trajectory and overall gait were calculated using permutation entropy and principal component analysis, respectively. Following treadmill testing, the animals were euthanized and hindlimb muscles removed. Excised muscles were tested for mass, density, fiber length, pennation angle, and relaxed sarcomere length. RESULTS: Muscle parameters were similar between groups with no evidence of muscle atrophy. The animals showed overextension of the ankle, which was compensated for by a decreased range of motion at the knee. Left-right coordination was altered, leading to left and right knee movements that are entirely out of phase, with one joint moving while the other is stationary. Movement patterns remained symmetric. Permutation entropy measures indicated changes in complexity on a joint specific basis, with the largest changes at the ankle. No significant difference was seen using principal component analysis. Rats were able to achieve stable weight bearing locomotion at reasonable speeds on the treadmill despite these deficiencies. CONCLUSIONS: Decrease in supraspinal control following iSCI causes a loss of complexity of ankle kinematics. This loss can be entirely due to loss of supraspinal control in the absence of muscle atrophy and may be quantified using permutation entropy. Joint-specific differences in kinematic complexity may be attributed to different sources of motor control. This work indicates the importance of the ankle for rehabilitation interventions following spinal cord injury.


Assuntos
Articulação do Tornozelo/fisiopatologia , Locomoção/fisiologia , Músculo Esquelético/fisiopatologia , Traumatismos da Medula Espinal/fisiopatologia , Animais , Articulação do Tornozelo/patologia , Atrofia , Fenômenos Biomecânicos , Feminino , Marcha/fisiologia , Músculo Esquelético/patologia , Ratos , Ratos Long-Evans , Traumatismos da Medula Espinal/patologia , Traumatismos da Medula Espinal/reabilitação
5.
Arch Phys Med Rehabil ; 93(5): 896-904, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22541312

RESUMO

OBJECTIVE: To investigate the longitudinal performance of a surgically implanted neuroprosthesis for lower-extremity exercise, standing, and transfers after spinal cord injury. DESIGN: Case series. SETTING: Research or outpatient physical therapy departments of 4 academic hospitals. PARTICIPANTS: Subjects (N=15) with thoracic or low cervical level spinal cord injuries who had received the 8-channel neuroprosthesis for exercise and standing. INTERVENTION: After completing rehabilitation with the device, the subjects were discharged to unrestricted home use of the system. A series of assessments were performed before discharge and at a follow-up appointment approximately 1 year later. MAIN OUTCOME MEASURES: Neuroprosthesis usage, maximum standing time, body weight support, knee strength, knee fatigue index, electrode stability, and component survivability. RESULTS: Levels of maximum standing time, body weight support, knee strength, and knee fatigue index were not statistically different from discharge to follow-up (P>.05). Additionally, neuroprosthesis usage was consistent with subjects choosing to use the system on approximately half of the days during each monitoring period. Although the number of hours using the neuroprosthesis remained constant, subjects shifted their usage to more functional standing versus more maintenance exercise, suggesting that the subjects incorporated the neuroprosthesis into their lives. Safety and reliability of the system were demonstrated by electrode stability and a high component survivability rate (>90%). CONCLUSIONS: This group of 15 subjects is the largest cohort of implanted lower-extremity neuroprosthetic exercise and standing system users. The safety and efficiency data from this group, and acceptance of the neuroprosthesis as demonstrated by continued usage, indicate that future efforts toward commercialization of a similar device may be warranted.


Assuntos
Joelho/fisiologia , Próteses Neurais , Aceitação pelo Paciente de Cuidados de Saúde , Traumatismos da Medula Espinal/fisiopatologia , Vértebras Cervicais , Feminino , Humanos , Estimativa de Kaplan-Meier , Estudos Longitudinais , Extremidade Inferior/fisiopatologia , Masculino , Fadiga Muscular , Força Muscular , Próteses Neurais/efeitos adversos , Falha de Prótese , Implantação de Prótese , Traumatismos da Medula Espinal/reabilitação , Traumatismos da Medula Espinal/cirurgia , Vértebras Torácicas , Fatores de Tempo , Suporte de Carga/fisiologia
6.
Sci Rep ; 10(1): 21903, 2020 12 14.
Artigo em Inglês | MEDLINE | ID: mdl-33318547

RESUMO

Mechanical ventilation is the standard treatment when volitional breathing is insufficient, but drawbacks include muscle atrophy, alveolar damage, and reduced mobility. Respiratory pacing is an alternative approach using electrical stimulation-induced diaphragm contraction to ventilate the lung. Oxygenation and acid-base homeostasis are maintained by matching ventilation to metabolic needs; however, current pacing technology requires manual tuning and does not respond to dynamic user-specific metabolic demand, thus requiring re-tuning of stimulation parameters as physiological changes occur. Here, we describe respiratory pacing using a closed-loop adaptive controller that can self-adjust in real-time to meet metabolic needs. The controller uses an adaptive Pattern Generator Pattern Shaper (PG/PS) architecture that autonomously generates a desired ventilatory pattern in response to dynamic changes in arterial CO2 levels and, based on a learning algorithm, modulates stimulation intensity and respiratory cycle duration to evoke this ventilatory pattern. In vivo experiments in rats with respiratory depression and in those with a paralyzed hemidiaphragm confirmed that the controller can adapt and control ventilation to ameliorate hypoventilation and restore normocapnia regardless of the cause of respiratory dysfunction. This novel closed-loop bioelectronic controller advances the state-of-art in respiratory pacing by demonstrating the ability to automatically personalize stimulation patterns and adapt to achieve adequate ventilation.


Assuntos
Algoritmos , Terapia por Estimulação Elétrica , Pulmão/fisiopatologia , Respiração , Animais , Masculino , Ratos , Ratos Sprague-Dawley , Respiração Artificial
7.
Contemp Clin Trials Commun ; 17: 100513, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32211555

RESUMO

The main motor impairments of gait and balance experienced by people with Parkinson's disease (PD) contribute to a sedentary lifestyle, resulting in poor physical conditioning, loss of functional independence, and reduced quality of life. Despite the known benefits of physical activity in PD, the majority of older adults with PD are insufficiently active. Few studies incorporate behavioral change approaches to promoting physical activity in PD. The main goal of this research is to foster community mobility in older adults with PD by promoting physical activity and improving gait patterns using a theory-based behavioral change intervention. The ReadySteady intervention combines wellness motivation theory with polestriding physical activity, which has been shown to be beneficial for people with PD. The intervention will be tested using a randomized controlled design, including inactive older adults diagnosed with PD. Participants will be randomly assigned the 12-week ReadySteady intervention, 12-week polestriding, and education intervention, or 12-week education intervention. Thirty-six older adults with PD will participate in each of the interventions. Level of physical activity, clinical scores, quantitative measures of gait and balance control, and motivational variables for each intervention will be measured at three time points: pre-intervention, post-intervention (12 weeks), and follow-up (24 weeks). If the intervention is beneficial, it may serve as a sustainable addition to current practice in health promotion efforts serving the PD population.

8.
J Neurosci Methods ; 176(2): 213-24, 2009 Jan 30.
Artigo em Inglês | MEDLINE | ID: mdl-18848960

RESUMO

Neuromuscular electrical stimulation (NMES) can provide functional movements in people after central nervous system injury. The neuroplastic effects of long-term NMES-induced repetitive limb movement are not well understood. A rodent model of neurotrauma in which NMES can be implemented may be effective for such investigations. We present a rodent model for NMES of the flexor and extensor muscles of the hip, knee, and ankle hindlimb muscles. Custom fabricated intramuscular stimulating electrodes for rodents were implanted near identified motor points of targeted muscles in ten adult, female Long Evans rats. The effects of altering NMES pulse stimulation parameters were characterized using strength duration curves, isometric joint torque recruitment curves and joint angle measures. The data indicate that short pulse widths have the advantage of producing graded torque recruitment curves when current is used as the control parameter. A stimulus frequency of 75 Hz or more produces fused contractions. The data demonstrate ability to accurately implant the electrodes and obtain selective, graded, repeatable, strong muscle contractions. Knee and ankle angular excursions comparable to those obtained in normal treadmill walking in the same rodent species can be obtained by stimulating the target muscles. Joint torques (normalized to body weight) obtained were larger than those reported in the literature for small tailed therian mammals and for peak isometric ankle plantarflexion in a different rodent species. This model system could be used for investigations of NMES assisted hindlimb movement therapy.


Assuntos
Estimulação Elétrica/métodos , Membro Posterior/fisiologia , Extremidade Inferior/fisiologia , Modelos Animais , Fenômenos Fisiológicos Musculoesqueléticos , Animais , Biofísica , Eletrodos , Eletromiografia/métodos , Feminino , Movimento/fisiologia , Contração Muscular/fisiologia , Ratos , Ratos Long-Evans , Torque
9.
PLoS One ; 14(1): e0210956, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30650161

RESUMO

Current myoelectric prosthetic limbs are limited in their ability to provide direct sensory feedback to users, which increases attentional demands and reliance on visual cues. Vibrotactile sensory substitution (VSS), which can be used to provide sensory feedback in a non-invasive manner has demonstrated some improvement in myoelectric hand control. In this work, we developed and tested two VSS configurations: one with a single burst-rate modulated actuator and another with a spatially distributed array of five coin tactors. We performed a direct comparative assessment of these two VSS configurations with able-bodied subjects to investigate sensory perception, myoelectric control of grasp force and hand aperture with a prosthesis, and the effects of interface compliance. Six subjects completed a sensory perception experiment under a stimulation only paradigm; sixteen subjects completed experiments to compare VSS performance on perception and graded myoelectric control during grasp force and hand aperture tasks; and ten subjects completed experiments to investigate the effect of mechanical compliance of the myoelectric hand on the ability to control grasp force. Results indicated that sensory perception of vibrotactile feedback was not different for the two VSS configurations in the absence of active myoelectric control, but it was better with feedback from the coin tactor array than with the single actuator during myoelectric control of grasp force. Graded myoelectric control of grasp force and hand aperture was better with feedback from the coin tactor array than with the single actuator, and myoelectric control of grasp force was improved with a compliant grasp interface. Further investigations with VSS should focus on the use of coin tactor arrays by subjects with amputation in real-world settings and on improving control of grasp force by increasing the mechanical compliance of the hand.


Assuntos
Membros Artificiais , Retroalimentação Sensorial/fisiologia , Força da Mão/fisiologia , Mãos/fisiologia , Tato/fisiologia , Adulto , Amputação Cirúrgica , Amputados , Fenômenos Biomecânicos , Complacência (Medida de Distensibilidade)/fisiologia , Simulação por Computador , Eletromiografia , Feminino , Humanos , Masculino , Percepção/fisiologia , Desenho de Prótese , Vibração , Adulto Jovem
10.
J Neurotrauma ; 36(24): 3363-3377, 2019 12 15.
Artigo em Inglês | MEDLINE | ID: mdl-31146654

RESUMO

Ventilatory pacing by electrical stimulation of the phrenic nerve or of the diaphragm has been shown to enhance quality of life compared to mechanical ventilation. However, commercially available ventilatory pacing devices require initial manual specification of stimulation parameters and frequent adjustment to achieve and maintain suitable ventilation over long periods of time. Here, we have developed an adaptive, closed-loop, neuromorphic, pattern-shaping controller capable of automatically determining a suitable stimulation pattern and adapting it to maintain a desired breath-volume profile on a breath-by-breath basis. The system adapts the pattern of stimulation parameters based on the error between the measured volume sampled every 40 ms and a desired breath volume profile. In vivo studies in anesthetized male Sprague-Dawley rats without and with spinal cord injury by spinal hemisection at C2 indicated that the controller was capable of automatically adapting stimulation parameters to attain a desired volume profile. Despite diaphragm hemiparesis, the controller was able to achieve a desired volume in the injured animals that did not differ from the tidal volume observed before injury (p = 0.39). Closed-loop adaptive pacing partially mitigated hypoventilation as indicated by reduction of end-tidal CO2 values during pacing. The closed-loop controller was developed and parametrized in a computational testbed before in vivo assessment. This bioelectronic technology could serve as an individualized and autonomous respiratory pacing approach for support or recovery from ventilatory deficiency.


Assuntos
Diafragma/fisiologia , Ventilação Pulmonar/fisiologia , Respiração Artificial/métodos , Traumatismos da Medula Espinal/fisiopatologia , Animais , Vértebras Cervicais/lesões , Diafragma/inervação , Masculino , Nervo Frênico/fisiologia , Ratos , Ratos Sprague-Dawley , Respiração Artificial/instrumentação , Traumatismos da Medula Espinal/terapia , Volume de Ventilação Pulmonar/fisiologia
11.
J Neurosci Methods ; 167(2): 317-26, 2008 Jan 30.
Artigo em Inglês | MEDLINE | ID: mdl-17870182

RESUMO

Upper extremity neuromuscular electrical stimulation (FNS) has long been utilized as a neuroprosthesis to restore hand-grasp function in individuals with neurological disorders and injuries. More recently, electrical stimulation is being used as a rehabilitative therapy to tap into central nervous system plasticity. Here, we present initial development of a rodent model for neuromuscular stimulation induced forelimb movement that can be used as a platform to investigate stimulation-induced plasticity. The motor points for flexors and extensors of the shoulder, elbow, and digits were identified and implanted with custom-built stimulation electrodes. The strength-duration curves were determined and from these curves the appropriate stimulation parameters required to produce consistent isolated contraction of each muscle with adequate joint movement were determined. Using these parameters and previous locomotor EMG data, stimulation was performed on each joint muscle pair to produce reciprocal flexion/extension movements in the shoulder, elbow, and digits, while 3D joint kinematics were assessed. Additionally, co-stimulation of multiple muscles across multiple forelimb joints was performed to produce stable multi-joint movements similar to those observed during reach-grasp-release movements. Future work will utilize this model to investigate the efficacy and underlying mechanisms of forelimb neuromuscular stimulation therapy to promote recovery and plasticity after neural injury in rodents.


Assuntos
Estimulação Elétrica/instrumentação , Estimulação Elétrica/métodos , Membro Anterior/inervação , Força Muscular/efeitos da radiação , Sistema Musculoesquelético/efeitos da radiação , Animais , Fenômenos Biomecânicos , Relação Dose-Resposta à Radiação , Eletrodos Implantados , Feminino , Membro Anterior/anatomia & histologia , Membro Anterior/fisiologia , Modelos Animais , Movimento/efeitos da radiação , Fadiga Muscular/efeitos da radiação , Força Muscular/fisiologia , Ratos , Ratos Long-Evans
12.
Gait Posture ; 27(2): 280-5, 2008 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-17507227

RESUMO

This study investigated the effects of altering foot placement for two individuals with spinal cord injuries (SCI) that stood using functional neuromuscular stimulation (FNS) as compared to an able-bodied subject group. FNS-assisted standers used parallel bars as needed for support, while the able-bodied group stood hands-free. Three different foot placements were tested: side-by-side, wide, and modified tandem. For SCI subjects, the percentage of body weight loaded on the feet was not greatly affected by foot placement, which potentially could be altered to provide postural benefits during functional tasks. Anterior/posterior (A/P) center of pressure (COP) origins tended to be located more anterior in the base of support for SCI subjects as compared to able-bodied subjects. SCI subjects also tended to have medial/lateral (M/L) COP excursions that were larger than able-bodied subjects. The sacrum appeared to hold some promise as a sensor location for monitoring A/P postural sway, but movements in the M/L direction were inconsistent and will require additional study. General guidelines such as positioning the A/P COP more posterior in the base of support and feedback concerning excessive M/L COP displacements may be useful to improve standing performance for SCI subjects. In addition, the modified tandem placement was an effective alternative for making postural adjustments in one SCI subject who experienced excessive right knee flexion with other foot placements.


Assuntos
Terapia por Estimulação Elétrica , Pé/fisiopatologia , Traumatismos da Medula Espinal/fisiopatologia , Traumatismos da Medula Espinal/reabilitação , Adaptação Fisiológica/fisiologia , Adulto , Análise de Variância , Fenômenos Biomecânicos , Feminino , Humanos , Masculino , Equilíbrio Postural/fisiologia , Postura/fisiologia , Pressão
13.
Bioelectron Med (Lond) ; 1(1): 55-69, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29480906

RESUMO

The network of peripheral nerves presents extraordinary potential for modulating and/or monitoring the functioning of internal organs or the brain. The degree to which these pathways can be used to influence or observe neural activity patterns will depend greatly on the quality and specificity of the bionic interface. The anatomical organization, which consists of multiple nerve fibers clustered into fascicles within a nerve bundle, presents opportunities and challenges that may necessitate insertion of electrodes into individual fascicles to achieve the specificity that may be required for many clinical applications. This manuscript reviews the current state-of-the-art in bionic intrafascicular interfaces, presents specific concerns for stimulation and recording, describes key implementation considerations and discusses challenges for future designs of bionic intrafascicular interfaces.

15.
Bioinspir Biomim ; 12(1): 016015, 2017 01 30.
Artigo em Inglês | MEDLINE | ID: mdl-28134133

RESUMO

Locomotion requires coordination of leg joints to maintain stability and to maneuver. We studied leg joint function during constant-average-velocity running and the sagittal-plane maneuvers of step ascent and descent. We tested two hypotheses: (1) that leg joints perform distinct functions during locomotion; and (2) that humans select functional parameters to maximize intrinsic dynamic stability. We recorded whole-body kinematics and forces when participants stepped up or down a single vertical step, and found that leg joints show functional differences during both constant-average-velocity locomotion and maneuvers. The hip, knee and ankle function as a motor, damper, and spring, respectively. We therefore constructed a simplified computational model of a human leg with a motor, damper, and spring in series (MDS). The intrinsic dynamics of the model resulted in sustained locomotion on level ground within narrow parameter ranges. However, using parameters experimentally derived from humans, the model showed only short-term stability. Humans may not optimize intrinsic dynamic stability alone, but may instead choose mechanical and behavioral parameters appropriate for both constant-average-velocity locomotion and maneuvers. Understanding joint-level mechanical function during unsteady locomotion helps to understand how differential joint function contributes to whole-body performance, and could lead to improvements in rehabilitation, prosthetic and robotic design.


Assuntos
Articulação do Tornozelo/fisiologia , Articulação do Quadril/fisiologia , Articulação do Joelho/fisiologia , Corrida/fisiologia , Adulto , Análise de Variância , Fenômenos Biomecânicos , Humanos , Perna (Membro) , Locomoção/fisiologia , Masculino , Terminologia como Assunto
16.
Nanobiomedicine (Rij) ; 4: 1849543517701158, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29942391

RESUMO

In the two decades after 1990, the rates of child and maternal mortality dropped by over 40% and 47%, respectively. Despite these improvements, which are in part due to increased access to medical technologies, profound health disparities exist. In 2015, a child born in a developing region is nearly eight times as likely to die before the age of 5 than one born in a developed region and developing regions accounted for nearly 99% of the maternal deaths. Recent developments in nanotechnology, however, have great potential to ameliorate these and other health disparities by providing new cost-effective solutions for diagnosis or treatment of a variety of medical conditions. Affordability is only one of the several challenges that will need to be met to translate new ideas into a medical product that addresses a global health need. This article aims to describe some of the other challenges that will be faced by nanotechnologists who seek to make an impact in low-resource settings across the globe.

17.
Annu Int Conf IEEE Eng Med Biol Soc ; 2017: 1970-1973, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29060280

RESUMO

Functional Electrical Stimulation can be used to restore motor functions loss consecutive to spinal cord injury, such as respiratory deficiency due to paralysis of ventilatory muscles. This paper presents a fully configurable IC-centered stimulator designed to investigate muscle stimulation paradigms. It provides 8 current stimulation channels with high-voltage compliance and real-time operation capabilities, to enable a wide range of FES applications. The stimulator can be used in a standalone mode, or within a closed-loop setup. Primary in vivo results show successful drive of respiratory muscles stimulation using a computer-based dedicated controller.


Assuntos
Músculos Respiratórios , Estimulação Elétrica , Terapia por Estimulação Elétrica , Humanos , Paralisia , Traumatismos da Medula Espinal
18.
IEEE J Biomed Health Inform ; 19(6): 1809-19, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26316235

RESUMO

For people with Parkinson's disease (PD), gait and postural impairments can significantly affect their ability to perform activities of daily living. Presentation of appropriate cues has been shown to improve gait in PD. Based on this, a treadmill-based system and experimental paradigm were developed to determine if people with PD can utilize real-time feedback (RTFB) of step length or back angle (uprightness) to improve gait and posture. Eleven subjects (mean age 67 ± 8 years) with mild-to-moderate PD (Hoehn and Yahr stage I-III) were evaluated regarding their ability to successfully utilize RTFB of back angle or step length during quiet standing and treadmill walking tasks during a single session in their medication-on state. Changes in back angle and step length due to feedback were compared using Friedman nonparametric tests with Wilcoxon Signed-Rank tests for post-hoc comparisons. Improvements in uprightness were observed as an increase in back angle during quiet standing (p = 0.005) and during treadmill walking (p = 0.005) with back angle feedback when compared to corresponding tasks without feedback. Improvements in gait were also observed as an increase in step length (p = 0.005) during step length feedback compared to tasks without feedback. These results indicate that people with mild-to-moderate PD can utilize RTFB to improve upright posture and gait. Future work will investigate the long-term effects of this RTFB paradigm and the development of systems for clinical or home-based use.


Assuntos
Retroalimentação , Marcha/fisiologia , Monitorização Fisiológica/métodos , Doença de Parkinson/fisiopatologia , Postura/fisiologia , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Monitorização Fisiológica/instrumentação , Processamento de Sinais Assistido por Computador
19.
J Neurosci Methods ; 244: 78-84, 2015 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-25092497

RESUMO

BACKGROUND: Several neural interface technologies that stimulate and/or record from groups of axons have been developed. The longitudinal intrafascicular electrode (LIFE) is a fine wire that can provide access to a discrete population of axons within a peripheral nerve fascicle. Some applications require, or would benefit greatly from, technology that could provide access to multiple discrete sites in several fascicles. NEW METHOD: The distributed intrafascicular multi-electrode (DIME) lead was developed to deploy multiple LIFEs to several fascicles. It consists of several (e.g. six) LIFEs that are coiled and placed in a sheath for strength and durability, with a portion left uncoiled to allow insertion at distinct sites. We have also developed a multi-lead multi-electrode (MLME) management system that includes a set of sheaths and procedures for fabrication and deployment. RESULTS: A prototype with 3 DIME leads was fabricated and tested in a procedure in a cadaver arm. The leads were successfully routed through skin and connective tissue and the deployment procedures were utilized to insert the LIFEs into fascicles of two nerves. COMPARISON WITH EXISTING METHOD(S): Most multi-electrode systems use a single-lead, multi-electrode design. For some applications, this design may be limited by the bulk of the multi-contact array and/or by the spatial distribution of the electrodes. CONCLUSION: We have designed a system that can be used to access multiple sets of discrete groups of fibers that are spatially distributed in one or more fascicles of peripheral nerves. This system may be useful for neural-enabled prostheses or other applications.


Assuntos
Potenciais de Ação/fisiologia , Axônios/fisiologia , Próteses Neurais , Nervos Periféricos/fisiologia , Animais , Estimulação Elétrica , Eletrodos , Desenho de Equipamento , Humanos , Interface Usuário-Computador
20.
IEEE Trans Neural Syst Rehabil Eng ; 11(4): 377-85, 2003 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-14960113

RESUMO

This study investigated the effects of altering foot placement on the strategies used by able-bodied subjects to perform reaching tasks while standing. The motivation for this study was to consider the results in the context of a person with a spinal cord injury using a functional neuromuscular stimulation (FNS) system to stand while reaching. Three foot placement conditions were compared as subjects reached to the left, right, and center. Centers of pressure (COP), joint angles, and joint moments were calculated as postural parameters using force platform and video marker data. Side-by-side and wide foot placements resulted in similar postural parameters. In contrast, the modified tandem stance (feet spaced at pelvic width with one foot shifted forward) resulted in anterior/posterior COP excursions that were larger in magnitude and more consistent across reach directions when compared to the other foot placement conditions. Furthermore, the movement patterns used during the tandem stance were more consistent and may be more readily achievable with FNS than the movement patterns utilized with the side-by-side and wide stances. These results suggest that the modified tandem stance may enhance the functionality of FNS standing systems and may also be useful in other standing rehabilitation programs.


Assuntos
Pé/fisiologia , Perna (Membro)/fisiologia , Movimento/fisiologia , Músculo Esquelético/fisiologia , Equilíbrio Postural/fisiologia , Postura/fisiologia , Extremidade Superior/fisiologia , Adaptação Fisiológica/fisiologia , Adulto , Humanos , Contração Muscular/fisiologia , Torque
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA