1.
Semin Musculoskelet Radiol ; 27(6): 632-640, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37935209

RESUMO

Arthritis has significant adverse consequences on musculoskeletal tissues and often other organs of the body. Current methods for clinical evaluation of arthritis are suboptimal, and biomarkers that are objective and measurable indicators for monitoring of arthritis disease activity are in critical demand. Recently, total-body positron emission tomography (PET) has been developed that can collect imaging signals synchronously from the entire body at ultra-low doses and reduced scan times. These scanners have increased signal collection efficiency that overcomes several limitations of standard PET scanners in the evaluation of arthritis, and they may potentially provide biomarkers to assess local and systemic impact of the arthritis disease process. This article reviews current results from using total-body PET in the assessment of common arthritic conditions, and it outlines future opportunities and challenges.


Assuntos
Artrite , Tomografia por Emissão de Pósitrons , Humanos , Tomografia por Emissão de Pósitrons/métodos , Artrite/diagnóstico por imagem , Previsões , Biomarcadores
2.
Respiration ; 102(9): 843-851, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37669638

RESUMO

BACKGROUND: Lung herniation has been described in case reports or series. There are scare data in the form of original research studies to systematically evaluate this condition. OBJECTIVE: Our aim was to evaluate lung hernias with a focus on their natural history. METHODS: This is a retrospective study at our institution of patients who were found to have lung herniation on imaging between September 2010 and November 2022. Electronic medical record review was performed to extract clinical information regarding patients. Computed tomographic imaging was used to evaluate hernia size and size progression over time with a median follow-up time of 3.8 years. RESULTS: Thirty-eight patients were eligible for analysis. Majority of patients were overweight or obese (31/38), smokers (31/38), had prior thoracic surgery (30/38), and were asymptomatic (33/38). Twenty of 38 patients had stability in hernia size, 12 of 38 patients had hernia size progression, and 6 of 38 patients showed hernia size regression. Younger age was found to be predictive of hernia size progression with age of 60 years being the cut-off for its prediction. CONCLUSION: Lung hernias typically either remain stable in size or show size progression. Younger age (60 years cut-off) was found to be predictive of size progression. This is the largest systematic investigation at a medical institution to the best of our knowledge of lung hernias which used computed tomographic imaging to follow up lung hernias. Further information could be given to patients with this condition and to clinicians for potential management guidance.


Assuntos
Registros Eletrônicos de Saúde , Obesidade , Humanos , Pessoa de Meia-Idade , Estudos Retrospectivos , Sobrepeso , Tórax
3.
BMC Med Imaging ; 23(1): 9, 2023 01 10.
Artigo em Inglês | MEDLINE | ID: mdl-36627570

RESUMO

BACKGROUND: Total-body positron emission tomography/computed tomography (PET/CT) scanners are characterized by higher signal collection efficiency and greater spatial resolution compared to conventional scanners, allowing for delayed imaging and improved image quality. These advantages may also lead to better detection of physiological processes that diagnostic imaging professionals should be aware of. The gallbladder (GB) is not usually visualized as an 18F-2-fluorodeoxyglucose (18F-FDG)-avid structure in routine clinical PET/CT studies; however, with the total-body PET/CT, we have been increasingly visualizing GB activity without it being involved in an inflammatory or neoplastic process. The aim of this study was to report visualization rates and characteristics of GB 18F-FDG uptake observed in both healthy and oncological subjects scanned on a total-body PET/CT system. MATERIALS AND METHODS: Scans from 73 participants (48 healthy and 25 with newly diagnosed lymphoma) who underwent 18F-FDG total-body PET/CT were retrospectively reviewed. Subjects were scanned at multiple timepoints up to 3 h post-injection. Gallbladder 18F-FDG activity was graded using liver uptake as a reference, and the pattern was qualified as present in the wall, lumen, or both. Participants' characteristics, such as age, sex, body-mass index, blood glucose, and other clinical parameters, were collected to assess for any significant correlation with GB 18F-FDG uptake. RESULTS: All 73 subjects showed GB uptake at one or more imaging timepoints. An increase in uptake intensity overtime was observed up until the 180-min scan, and the visualization rate of GB 18F-FDG uptake was 100% in the 120- and 180-min post-injection scans. GB wall uptake was detected in a significant number of patients (44/73, 60%), especially at early timepoint scans, whereas luminal activity was detected in 71/73 (97%) subjects, especially at later timepoint scans. No significant correlation was found between GB uptake intensity/pattern and subjects' characteristics. CONCLUSION: The consistent observation of GB 18F-FDG uptake recorded in this study in healthy participants and subjects with a new oncological diagnosis indicates that this is a normal physiologic finding rather than representing an exception.


Assuntos
Fluordesoxiglucose F18 , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Humanos , Vesícula Biliar/diagnóstico por imagem , Compostos Radiofarmacêuticos , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos , Tomografia por Emissão de Pósitrons/métodos
4.
J Digit Imaging ; 36(3): 1049-1059, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36854923

RESUMO

Deep learning (DL) has been proposed to automate image segmentation and provide accuracy, consistency, and efficiency. Accurate segmentation of lipomatous tumors (LTs) is critical for correct tumor radiomics analysis and localization. The major challenge of this task is data heterogeneity, including tumor morphological characteristics and multicenter scanning protocols. To mitigate the issue, we aimed to develop a DL-based Super Learner (SL) ensemble framework with different data correction and normalization methods. Pathologically proven LTs on pre-operative T1-weighted/proton-density MR images of 185 patients were manually segmented. The LTs were categorized by tumor locations as distal upper limb (DUL), distal lower limb (DLL), proximal upper limb (PUL), proximal lower limb (PLL), or Trunk (T) and grouped by 80%/9%/11% for training, validation and testing. Six configurations of correction/normalization were applied to data for fivefold-cross-validation trainings, resulting in 30 base learners (BLs). A SL was obtained from the BLs by optimizing SL weights. The performance was evaluated by dice-similarity-coefficient (DSC), sensitivity, specificity, and Hausdorff distance (HD95). For predictions of the BLs, the average DSC, sensitivity, and specificity from the testing data were 0.72 [Formula: see text] 0.16, 0.73 [Formula: see text] 0.168, and 0.99 [Formula: see text] 0.012, respectively, while for SL predictions were 0.80 [Formula: see text] 0.184, 0.78 [Formula: see text] 0.193, and 1.00 [Formula: see text] 0.010. The average HD95 of the BLs were 11.5 (DUL), 23.2 (DLL), 25.9 (PUL), 32.1 (PLL), and 47.9 (T) mm, whereas of SL were 1.7, 8.4, 15.9, 2.2, and 36.6 mm, respectively. The proposed method could improve the segmentation accuracy and mitigate the performance instability and data heterogeneity aiding the differential diagnosis of LTs in real clinical situations.


Assuntos
Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Humanos , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Inteligência Artificial
5.
BMC Infect Dis ; 22(1): 623, 2022 Jul 17.
Artigo em Inglês | MEDLINE | ID: mdl-35843935

RESUMO

BACKGROUND: Pericardial disease can be a manifestation of infection and imaging can have a role in its diagnosis. coccidioidomycosis endemic fungal infection has been more frequently reported over the past few decades. Other than case reports or series, there has been no systemic study evaluating pericardial imaging findings in patients with coccidioidomycosis to the best of our knowledge. The purpose of this study was to evaluate intrathoracic computed tomographic (CT) imaging abnormalities in patients with coccidioidal infection with specific emphasis on the pericardium. METHODS: Retrospective review of radiology reports and clinical chart review was performed to identify patients with coccidioidomycosis between January 2000 and September 2021 at our medical center. Diagnosis of infection was confirmed predominately with serology. Patients were excluded if a CT was not performed within 3 months of confirmed diagnosis date and if there was concomitant additional granulomatous or fungal infection. Chest CT was reviewed for pericardial and additional intrathoracic findings. RESULTS: The final retrospective cohort consisted of 37 patients. Imaging findings included lung nodules (N = 33/37), consolidation (N = 25/37), mediastinal or hilar lymphadenopathy (N = 20/37) and pleural effusions (N = 13/37). Eleven of 37 patients (30%) had either trace pericardial fluid (N = 3/37) or small pericardial effusions (N = 8/37). One patient had pericardial enhancement/thickening and history of pericardial tamponade. No other patient had clinical pericarditis or pericardial tamponade. Pericardial calcifications were not seen in any patient. Pericardial effusion was statistically associated with presence of pleural effusion as 9/13 patients with pleural effusion had pericardial effusion versus 2/26 patients without pleural effusion had pericardial effusion (p < 0.001). Otherwise patients with and without pericardial imaging findings were similar in terms of demographics, comorbidities and other imaging findings. CONCLUSION: Pulmonary parenchymal pathology is a common manifestation of coccidioidal infection. Most patients with coccidioidomycosis do not have pericardial imaging abnormalities on CT.


Assuntos
Tamponamento Cardíaco , Coccidioidomicose , Derrame Pericárdico , Derrame Pleural , Coccidioidomicose/diagnóstico por imagem , Coccidioidomicose/microbiologia , Humanos , Derrame Pericárdico/diagnóstico por imagem , Derrame Pleural/microbiologia , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos
6.
J Oral Maxillofac Surg ; 79(5): 1083.e1-1083.e10, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33358710

RESUMO

PURPOSE: The purpose of this study is to evaluate the utility of hybrid single-photon emission computed tomography (SPECT) and computed tomography (CT) with technetium-99m methylene diphosphonate in patients with suspected active unilateral condylar hyperplasia (UCH) using histopathology as the reference standard. METHODS: Twenty-four patients with suspected active UCH prospectively underwent technetium-99m methylene diphosphonate planar bone scintigraphy with SPECT/CT of the mandible. Qualitative and quantitative readings for growth activity were performed by 3 nuclear medicine physicians and the final diagnosis was derived from postoperative histopathological examination. Readings were reported as positive, equivocal, or negative. Total, maximum, and mean counts were recorded for each condyle on SPECT/CT images. The uptake of the index (suspected) condyle was expressed as a count ratio (Rtotal, Rmean, Rmax), a percentage uptake (Ptotal, Pmean, Pmax), background-corrected counts (Btotal, Bmean, Bmax), as well as CT-based condylar diameters (RCT,PCT) relative to the contralateral condyle. RESULTS: Interobserver agreement was 0.79 and 0.83 for planar bone scintigraphy and SPECT/CT, respectively, with a total of 5 and 1 equivocal readings from the respective modalities. Surgery was performed in 22 patients; all of them had pathologically proven UCH. SPECT/CT was slightly more sensitive than planar bone scintigraphy (91 vs 78%) with identical specificity (96%). Rtotal, Rmean, Ptotal, and Pmean demonstrated area under the curve between 84% and 86%. Metrics based on CT diameters and background-corrected counts were not associated with UCH diagnosis. CONCLUSIONS: Quantitative approaches based on total or mean count ratio or relative count percentage were equally predictive for UCH diagnosis; however, they were slightly less sensitive compared with qualitative technetium-99m methylene diphosphonate SPECT/CT evaluation. SPECT/CT evaluation has the potential to decrease the equivocal readings.


Assuntos
Côndilo Mandibular , Medronato de Tecnécio Tc 99m , Humanos , Hiperplasia/diagnóstico por imagem , Côndilo Mandibular/diagnóstico por imagem , Côndilo Mandibular/patologia , Compostos Radiofarmacêuticos , Tomografia Computadorizada de Emissão de Fóton Único , Tomografia Computadorizada por Raios X
7.
Vet Radiol Ultrasound ; 62(4): 445-454, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33634942

RESUMO

Magnetic resonance imaging is the primary method used to diagnose canine glial cell neoplasia and noninfectious inflammatory meningoencephalitis. Subjective differentiation of these diseases can be difficult due to overlapping imaging characteristics. This study utilizes texture analysis (TA) of intra-axial lesions both as a means to quantitatively differentiate these broad categories of disease and to help identify glial tumor grade/cell type and specific meningoencephalitis subtype in a group of 119 dogs with histologically confirmed diagnoses. Fifty-nine dogs with gliomas and 60 dogs with noninfectious inflammatory meningoencephalitis were retrospectively recruited and randomly split into training (n = 80) and test (n = 39) cohorts. Forty-five of 120 texture metrics differed significantly between cohorts after correcting for multiple testing (false discovery rate < 0.05). After training the random forest algorithm, the classification accuracy for the test set was 85% (sensitivity 89%, specificity 81%). TA was only partially able to differentiate the inflammatory subtypes (granulomatous meningoencephalitis [GME], necrotizing meningoencephalitis [NME], and necrotizing leukoencephalitis [NLE]) (out-of-bag error rate of 35.0%) and was unable to identify metrics that could correctly classify glioma grade or cell type (out-of-bag error rate of 59.6% and 47.5%, respectively). Multiple demographic differences, such as patient age, sex, weight, and breed were identified between disease cohorts and subtypes which may be useful in prioritizing differential diagnoses. TA of MR images with a random forest algorithm provided classification accuracy of inflammatory and neoplastic brain disease approaching the accuracy of previously reported subjective radiologist evaluation.


Assuntos
Neoplasias Encefálicas/veterinária , Doenças do Cão/diagnóstico por imagem , Imageamento por Ressonância Magnética/veterinária , Meningoencefalite/veterinária , Animais , Neoplasias Encefálicas/patologia , Doenças do Cão/patologia , Cães , Granuloma/complicações , Masculino , Meningoencefalite/complicações , Meningoencefalite/diagnóstico por imagem , Estudos Retrospectivos
8.
Skeletal Radiol ; 49(6): 1005-1014, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31965239

RESUMO

OBJECTIVES: The objectives of the study are (1) to distinguish lipoma (L) from atypical lipomatous tumor (ALT) using MRI qualitative features, (2) to assess the value of contrast enhancement, and (3) to evaluate the reproducibility and confidence level of radiological readings. MATERIALS AND METHODS: Patients with pathologically proven L or ALT, who underwent MRI within 3 months from surgical excision were included in this retrospective multicenter international study. Two radiologists independently reviewed MRI centrally. Impressions were recorded as L or ALT. A third radiologist was consulted for discordant readings. The two radiologists re-read all non-contrast sequences; impression was recorded; then post-contrast images were reviewed and any changes were recorded. RESULTS: A total of 246 patients (135 females; median age, 59 years) were included. ALT was histopathologically confirmed in 70/246 patients. In multivariable analysis, in addition to the lesion size, deep location, proximal lower limb lesions, demonstrating incomplete fat suppression, or increased architectural complexity were the independent predictive features of ALT; but not the contrast enhancement. Post-contrast MRI changed the impression in a total of 5 studies (3 for R1 and 4 for R2; 2 studies are common); all of them were incorrectly changed from Ls to ALTs. Overall, inter-reader kappa agreement was 0.42 (95% CI 0.39-0.56). Discordance between the two readers was statistically significant for both pathologically proven L (p < 0.001) and ALT (p = 0.003). CONCLUSION: Most qualitative MR imaging features can help distinguish ALTs from BLs. However, contrast enhancement may be limited and occasionally misleading. Substantial discordance on MRI readings exists between radiologists with a relatively high false positive and negative rates.


Assuntos
Lipoma/diagnóstico por imagem , Lipossarcoma/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Meios de Contraste , Feminino , Humanos , Lipoma/patologia , Lipossarcoma/patologia , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos
9.
Clin Imaging ; 112: 110193, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38820977

RESUMO

PURPOSE: To assess ChatGPT's ability as a resource for educating patients on various aspects of cardiac imaging, including diagnosis, imaging modalities, indications, interpretation of radiology reports, and management. METHODS: 30 questions were posed to ChatGPT-3.5 and ChatGPT-4 three times in three separate chat sessions. Responses were scored as correct, incorrect, or clinically misleading categories by three observers-two board certified cardiologists and one board certified radiologist with cardiac imaging subspecialization. Consistency of responses across the three sessions was also evaluated. Final categorization was based on majority vote between at least two of the three observers. RESULTS: ChatGPT-3.5 answered seventeen of twenty eight questions correctly (61 %) by majority vote. Twenty one of twenty eight questions were answered correctly (75 %) by ChatGPT-4 by majority vote. Majority vote for correctness was not achieved for two questions. Twenty six of thirty questions were answered consistently by ChatGPT-3.5 (87 %). Twenty nine of thirty questions were answered consistently by ChatGPT-4 (97 %). ChatGPT-3.5 had both consistent and correct responses to seventeen of twenty eight questions (61 %). ChatGPT-4 had both consistent and correct responses to twenty of twenty eight questions (71 %). CONCLUSION: ChatGPT-4 had overall better performance than ChatGTP-3.5 when answering cardiac imaging questions with regard to correctness and consistency of responses. While both ChatGPT-3.5 and ChatGPT-4 answers over half of cardiac imaging questions correctly, inaccurate, clinically misleading and inconsistent responses suggest the need for further refinement before its application for educating patients about cardiac imaging.


Assuntos
Inteligência Artificial , Humanos , Técnicas de Imagem Cardíaca/métodos , Educação de Pacientes como Assunto/métodos
10.
Phys Med Biol ; 69(4)2024 Feb 16.
Artigo em Inglês | MEDLINE | ID: mdl-38266297

RESUMO

Objective.This study presents and evaluates a robust Monte Carlo-based scatter correction (SC) method for long axial field of view (FOV) and total-body positron emission tomography (PET) using the uEXPLORER total-body PET/CT scanner.Approach.Our algorithm utilizes the Monte Carlo (MC) tool SimSET to compute SC factors in between individual image reconstruction iterations within our in-house list-mode and time-of-flight-based image reconstruction framework. We also introduced a unique scatter scaling technique at the detector block-level for optimal estimation of the scatter contribution in each line of response. First image evaluations were derived from phantom data spanning the entire axial FOV along with image data from a human subject with a large body mass index. Data was evaluated based on qualitative inspections, and contrast recovery, background variability, residual scatter removal from cold regions, biases and axial uniformity were quantified and compared to non-scatter-corrected images.Main results.All reconstructed images demonstrated qualitative and quantitative improvements compared to non-scatter-corrected images: contrast recovery coefficients improved by up to 17.2% and background variability was reduced by up to 34.3%, and the residual lung error was between 1.26% and 2.08%. Low biases throughout the axial FOV indicate high quantitative accuracy and axial uniformity of the corrections. Up to 99% of residual activity in cold areas in the human subject was removed, and the reliability of the method was demonstrated in challenging body regions like in the proximity of a highly attenuating knee prosthesis.Significance.The MC SC method employed was demonstrated to be accurate and robust in TB-PET. The results of this study can serve as a benchmark for optimizing the quantitative performance of future SC techniques.


Assuntos
Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Tomografia por Emissão de Pósitrons , Humanos , Reprodutibilidade dos Testes , Espalhamento de Radiação , Tomografia por Emissão de Pósitrons/métodos , Algoritmos , Método de Monte Carlo , Imagens de Fantasmas , Processamento de Imagem Assistida por Computador/métodos
11.
J Nucl Med ; 65(7): 1101-1106, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38664017

RESUMO

Our aim was to define a lower limit of reduced injected activity in delayed [18F]FDG total-body (TB) PET/CT in pediatric oncology patients. Methods: In this single-center prospective study, children were scanned for 20 min with TB PET/CT, 120 min after intravenous administration of a 4.07 ± 0.49 MBq/kg dose of [18F]FDG. Five randomly subsampled low-count reconstructions were generated using », ⅛, [Formula: see text], and [Formula: see text] of the counts in the full-dose list-mode reference standard acquisition (20 min), to simulate dose reduction. For the 2 lowest-count reconstructions, smoothing was applied. Background uptake was measured with volumes of interest placed on the ascending aorta, right liver lobe, and third lumbar vertebra body (L3). Tumor lesions were segmented using a 40% isocontour volume-of-interest approach. Signal-to-noise ratio, tumor-to-background ratio, and contrast-to-noise ratio were calculated. Three physicians identified malignant lesions independently and assessed the image quality using a 5-point Likert scale. Results: In total, 113 malignant lesions were identified in 18 patients, who met the inclusion criteria. Of these lesions, 87.6% were quantifiable. Liver SUVmean did not change significantly, whereas a lower signal-to-noise ratio was observed in all low-count reconstructions compared with the reference standard (P < 0.0001) because of higher noise rates. Tumor uptake (SUVmax), tumor-to-background ratio, and total lesion count were significantly lower in the reconstructions with [Formula: see text] and [Formula: see text] of the counts of the reference standard (P < 0.001). Contrast-to-noise ratio and clinical image quality were significantly lower in all low-count reconstructions than with the reference standard. Conclusion: Dose reduction for delayed [18F]FDG TB PET/CT imaging in children is possible without loss of image quality or lesion conspicuity. However, our results indicate that to maintain comparable tumor uptake and lesion conspicuity, PET centers should not reduce the injected [18F]FDG activity below 0.5 MBq/kg when using TB PET/CT in pediatric imaging at 120 min after injection.


Assuntos
Fluordesoxiglucose F18 , Neoplasias , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Doses de Radiação , Imagem Corporal Total , Humanos , Criança , Feminino , Masculino , Neoplasias/diagnóstico por imagem , Adolescente , Pré-Escolar , Estudos Prospectivos , Compostos Radiofarmacêuticos , Razão Sinal-Ruído , Processamento de Imagem Assistida por Computador , Fatores de Tempo
12.
J Nucl Med ; 65(5): 714-721, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38548347

RESUMO

The lungs are supplied by both the pulmonary arteries carrying deoxygenated blood originating from the right ventricle and the bronchial arteries carrying oxygenated blood downstream from the left ventricle. However, this effect of dual blood supply has never been investigated using PET, partially because the temporal resolution of conventional dynamic PET scans is limited. The advent of PET scanners with a long axial field of view, such as the uEXPLORER total-body PET/CT system, permits dynamic imaging with high temporal resolution (HTR). In this work, we modeled the dual-blood input function (DBIF) and studied its impact on the kinetic quantification of normal lung tissue and lung tumors using HTR dynamic PET imaging. Methods: Thirteen healthy subjects and 6 cancer subjects with lung tumors underwent a dynamic 18F-FDG scan with the uEXPLORER for 1 h. Data were reconstructed into dynamic frames of 1 s in the early phase. Regional time-activity curves of lung tissue and tumors were analyzed using a 2-tissue compartmental model with 3 different input functions: the right ventricle input function, left ventricle input function, and proposed DBIF, all with time delay and dispersion corrections. These models were compared for time-activity curve fitting quality using the corrected Akaike information criterion and for differentiating lung tumors from lung tissue using the Mann-Whitney U test. Voxelwise multiparametric images by the DBIF model were further generated to verify the regional kinetic analysis. Results: The effect of dual blood supply was pronounced in the high-temporal-resolution time-activity curves of lung tumors. The DBIF model achieved better time-activity curve fitting than the other 2 single-input models according to the corrected Akaike information criterion. The estimated fraction of left ventricle input was low in normal lung tissue of healthy subjects but much higher in lung tumors (∼0.04 vs. ∼0.3, P < 0.0003). The DBIF model also showed better robustness in the difference in 18F-FDG net influx rate [Formula: see text] and delivery rate [Formula: see text] between lung tumors and normal lung tissue. Multiparametric imaging with the DBIF model further confirmed the differences in tracer kinetics between normal lung tissue and lung tumors. Conclusion: The effect of dual blood supply in the lungs was demonstrated using HTR dynamic imaging and compartmental modeling with the proposed DBIF model. The effect was small in lung tissue but nonnegligible in lung tumors. HTR dynamic imaging with total-body PET can offer a sensitive tool for investigating lung diseases.


Assuntos
Neoplasias Pulmonares , Tomografia por Emissão de Pósitrons , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/metabolismo , Masculino , Feminino , Pessoa de Meia-Idade , Cinética , Tomografia por Emissão de Pósitrons/métodos , Modelos Biológicos , Adulto , Fluordesoxiglucose F18 , Idoso , Imagem Corporal Total , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Processamento de Imagem Assistida por Computador , Fatores de Tempo , Compostos Radiofarmacêuticos/farmacocinética
13.
Phys Med Biol ; 68(21)2023 10 26.
Artigo em Inglês | MEDLINE | ID: mdl-37802064

RESUMO

Objective.Contrast recovery coefficient (CRC) is essential for image quality (IQ) assessment in positron emission tomography (PET), typically measured according to the National Electrical Manufacturers Association (NEMA) NU 2 standard. This study quantifies systematic uncertainties of the CRC measurement by a numerical investigation of the effects from scanner-independent parameters like voxel size, region-of-interest (ROI) misplacement, and sphere position on the underlying image grid.Approach.CRC measurements with 2D and 3D ROIs were performed on computer-generated images of a NEMA IQ-like phantom, using voxel sizes of 1-4 mm for sphere diameters of 5-40 mm-first in absence of noise and blurring, then with simulated spatial resolution and image noise with varying noise levels. The systematic uncertainties of the CRC measurement were quantified from above variations of scanner-independent parameters. Subsampled experimental images of a NEMA IQ phantom were additionally used to investigate the impact of ROI misplacement at different noise levels.Main results.In absence of noise and blurring, systematic uncertainties were up to 28.8% and 31.0% with 2D and 3D ROIs, respectively, for the 10 mm sphere, with the highest impact from ROI misplacement. In all cases, smaller spheres showed higher uncertainties with larger voxels. Contrary to prior assumptions, the use of 3D ROIs did not exhibit less susceptibility for parameter changes. Experimental and computer-generated images both demonstrated considerable variations on individual CRC measurements when background coefficient-of-variation exceeded 20%, despite negligible effects on mean CRC.Significance.This study underscores the effect of scanner-independent parameters on reliability, reproducibility, and comparability of CRC measurements. Our findings highlight the trade-off between the benefits of smaller voxel sizes and noise-induced CRC fluctuations, which is not considered in the current version of the NEMA IQ standards. The results furthermore warrant adjustments to the standard to accommodate the advances in sensitivity and spatial resolution of current-generation PET scanners.


Assuntos
Tomografia por Emissão de Pósitrons , Tomografia Computadorizada por Raios X , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X/métodos , Tomografia por Emissão de Pósitrons/métodos , Padrões de Referência , Imagens de Fantasmas , Processamento de Imagem Assistida por Computador
14.
J Nucl Med ; 64(8): 1304-1309, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37268426

RESUMO

Total-body PET/CT images can be rendered to produce images of a subject's face and body. In response to privacy and identifiability concerns when sharing data, we have developed and validated a workflow that obscures (defaces) a subject's face in 3-dimensional volumetric data. Methods: To validate our method, we measured facial identifiability before and after defacing images from 30 healthy subjects who were imaged with both [18F]FDG PET and CT at either 3 or 6 time points. Briefly, facial embeddings were calculated using Google's FaceNet, and an analysis of clustering was used to estimate identifiability. Results: Faces rendered from CT images were correctly matched to CT scans at other time points at a rate of 93%, which decreased to 6% after defacing. Faces rendered from PET images were correctly matched to PET images at other time points at a maximum rate of 64% and to CT images at a maximum rate of 50%, both of which decreased to 7% after defacing. We further demonstrated that defaced CT images can be used for attenuation correction during PET reconstruction, introducing a maximum bias of -3.3% in regions of the cerebral cortex nearest the face. Conclusion: We believe that the proposed method provides a baseline of anonymity and discretion when sharing image data online or between institutions and will help to facilitate collaboration and future regulatory compliance.


Assuntos
Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Privacidade , Humanos , Tomografia Computadorizada por Raios X/métodos , Tomografia por Emissão de Pósitrons/métodos , Processamento de Imagem Assistida por Computador/métodos , Fluordesoxiglucose F18
15.
medRxiv ; 2023 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-37790461

RESUMO

Immunotherapies, especially the checkpoint inhibitors such as anti-PD-1 antibodies, have transformed cancer treatment by enhancing immune system's capability to target and kill cancer cells. However, predicting immunotherapy response remains challenging. 18F-AraG is a molecular imaging tracer targeting activated T cells, which may facilitate therapy response assessment by non-invasive quantification of immune cell activity within tumor microenvironment and elsewhere in the body. The aim of this study was to obtain preliminary data on total-body pharmacokinetics of 18F-AraG, as a potential quantitative biomarker for immune response evaluation. Methods: The study consisted of 90-min total-body dynamic scans of four healthy subjects and one non-small cell lung cancer (NSCLC) patient, scanned before and after anti-PD-1 immunotherapy. Compartmental modeling with Akaike information criterion model selection were employed to analyze tracer kinetics in various organs. Additionally, seven sub-regions of the primary lung tumor and four mediastinal lymph nodes were analyzed. Practical identifiability analysis was performed to assess reliability of kinetic parameter estimation. Correlations of SUVmean, SUVR (tissue-to-blood ratio), and Logan plot slope KLogan with total volume-of-distribution VT were calculated to identify potential surrogates for kinetic modeling. Results: Strong correlations were observed between KLogan and SUVR values with VT, suggesting that they can be used as promising surrogates for VT, especially in organs with low blood-volume fraction. Moreover, the practical identifiability analysis suggests that the dynamic 18F-AraG PET scans could potentially be shortened to 60 minutes, while maintaining quantification accuracy for all organs-of-interest. The study suggests that although 18F-AraG SUV images can provide insights on immune cell distribution, kinetic modeling or graphical analysis methods may be required for accurate quantification of immune response post-therapy. While SUVmean showed variable changes in different sub-regions of the tumor post-therapy, the SUVR, KLogan, and VT showed consistent increasing trends in all analyzed sub-regions of the tumor with high practical identifiability. Conclusion: Our findings highlight the promise of 18F-AraG dynamic imaging as a non-invasive biomarker for quantifying the immune response to immunotherapy in cancer patients. The promising total-body kinetic modeling results also suggest potentially wider applications of the tracer in investigating the role of T cells in the immunopathogenesis of diseases.

16.
J Nucl Med ; 64(11): 1821-1830, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37591539

RESUMO

Conventional whole-body static 18F-FDG PET imaging provides a semiquantitative evaluation of overall glucose metabolism without insight into the specific transport and metabolic steps. Here we demonstrate the ability of total-body multiparametric 18F-FDG PET to quantitatively evaluate glucose metabolism using macroparametric quantification and assess specific glucose delivery and phosphorylation processes using microparametric quantification for studying recovery from coronavirus disease 2019 (COVID-19). Methods: The study included 13 healthy subjects and 12 recovering COVID-19 subjects within 8 wk of confirmed diagnosis. Each subject had a 1-h dynamic 18F-FDG scan on the uEXPLORER total-body PET/CT system. Semiquantitative SUV and the SUV ratio relative to blood (SUVR) were calculated for different organs to measure glucose utilization. Tracer kinetic modeling was performed to quantify the microparametric blood-to-tissue 18F-FDG delivery rate [Formula: see text] and the phosphorylation rate k 3, as well as the macroparametric 18F-FDG net influx rate ([Formula: see text]). Statistical tests were performed to examine differences between healthy subjects and recovering COVID-19 subjects. The effect of COVID-19 vaccination was also investigated. Results: We detected no significant difference in lung SUV but significantly higher lung SUVR and [Formula: see text] in COVID-19 recovery, indicating improved sensitivity of kinetic quantification for detecting the difference in glucose metabolism. A significant difference was also observed in the lungs with the phosphorylation rate k 3 but not with [Formula: see text], which suggests that glucose phosphorylation, rather than glucose delivery, drives the observed difference of glucose metabolism. Meanwhile, there was no or little difference in bone marrow 18F-FDG metabolism measured with SUV, SUVR, and [Formula: see text] but a significantly higher bone marrow [Formula: see text] in the COVID-19 group, suggesting a difference in glucose delivery. Vaccinated COVID-19 subjects had a lower lung [Formula: see text] and a higher spleen [Formula: see text] than unvaccinated COVID-19 subjects. Conclusion: Higher lung glucose metabolism and bone marrow glucose delivery were observed with total-body multiparametric 18F-FDG PET in recovering COVID-19 subjects than in healthy subjects, implying continued inflammation during recovery. Vaccination demonstrated potential protection effects. Total-body multiparametric PET of 18F-FDG can provide a more sensitive tool and more insights than conventional whole-body static 18F-FDG imaging to evaluate metabolic changes in systemic diseases such as COVID-19.


Assuntos
COVID-19 , Fluordesoxiglucose F18 , Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Vacinas contra COVID-19 , COVID-19/diagnóstico por imagem , Glucose , Tomografia por Emissão de Pósitrons/métodos
17.
medRxiv ; 2023 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-36993568

RESUMO

With the majority of CD8+ T cells residing and functioning in tissue, not blood, developing noninvasive methods for in vivo quantification of their biodistribution and kinetics in humans offers the means for studying their key role in adaptive immune response and memory. This study is the first report on using positron emission tomography (PET) dynamic imaging and compartmental kinetic modeling for in vivo measurement of whole-body biodistribution of CD8+ T cells in human subjects. For this, a 89Zr-labeled minibody with high affinity for human CD8 (89Zr-Df-Crefmirlimab) was used with total-body PET in healthy subjects (N=3) and in COVID-19 convalescent patients (N=5). The high detection sensitivity, total-body coverage, and the use of dynamic scans enabled the study of kinetics simultaneously in spleen, bone marrow, liver, lungs, thymus, lymph nodes, and tonsils, at reduced radiation doses compared to prior studies. Analysis and modeling of the kinetics was consistent with T cell trafficking effects expected from immunobiology of lymphoid organs, suggesting early uptake in spleen and bone marrow followed by redistribution and delayed increasing uptake in lymph nodes, tonsils, and thymus. Tissue-to-blood ratios from the first 7 h of CD8-targeted imaging showed significantly higher values in the bone marrow of COVID-19 patients compared to controls, with an increasing trend between 2 and 6 months post-infection, consistent with net influx rates obtained by kinetic modeling and flow cytometry analysis of peripheral blood samples. These results provide the platform for using dynamic PET scans and kinetic modelling to study total-body immunological response and memory.

18.
medRxiv ; 2023 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-37034643

RESUMO

Conventional whole-body 18 F-FDG PET imaging provides a semi-quantitative evaluation of overall glucose metabolism without gaining insight into the specific transport and metabolic steps. Here we demonstrate the ability of total-body multiparametric 18 F-FDG PET to quantitatively evaluate glucose metabolism using macroparametric quantification and assess specific glucose delivery and phosphorylation processes using microparametric quantification for studying recovery from coronavirus disease 2019 (COVID-19). Methods: The study included thirteen healthy subjects and twelve recovering COVID-19 subjects within eight weeks of confirmed diagnosis. Each subject had a dynamic 18 F-FDG scan on the uEXPLORER total-body PET/CT system for one hour. Semiquantitative standardized uptake value (SUV) and SUV ratio relative to blood (SUVR) were calculated for regions of interest (ROIs) in different organs to measure glucose utilization. Tracer kinetic modeling was performed to quantify microparametric rate constants K 1 and k 3 that characterize 18 F-FDG blood-to-tissue delivery and intracellular phosphorylation, respectively, and a macroparameter K i that represents 18 F-FDG net influx rate. Statistical tests were performed to examine differences between the healthy controls and recovering COVID-19 subjects. Impact of COVID-19 vaccination was investigated. We further generated parametric images to confirm the ROI-based analysis. Results: We detected no significant difference in lung SUV but significantly higher lung SUVR and K i in the recovering COVID-19 subjects, indicating an improved sensitivity of kinetic quantification for detecting the difference in glucose metabolism. A significant difference was also observed in the lungs with the phosphorylation rate k 3 , but not with the delivery rate K 1 , which suggests it is glucose phosphorylation, not glucose delivery, that drives the observed difference of glucose metabolism in the lungs. Meanwhile, there was no or little difference in bone marrow metabolism measured with SUV, SUVR and K i , but a significant increase in bone-marrow 18 F-FDG delivery rate K 1 in the COVID-19 group ( p < 0.05), revealing a difference of glucose delivery in this immune-related organ. The observed differences were lower or similar in vaccinated COVID-19 subjects as compared to unvaccinated ones. The organ ROI-based findings were further supported by parametric images. Conclusions: Higher lung glucose metabolism and bone-marrow glucose delivery were observed with total-body multiparametric 18 F-FDG PET in recovering COVID-19 subjects as compared to healthy subjects, which suggests continued inflammation due to COVID-19 during the early stages of recovery. Total-body multiparametric PET of 18 F-FDG delivery and metabolism can provide a more sensitive tool and more insights than conventional static whole-body 18 F-FDG imaging to evaluate metabolic changes in systemic diseases such as COVID-19.

19.
Sci Adv ; 9(41): eadh7968, 2023 10 13.
Artigo em Inglês | MEDLINE | ID: mdl-37824612

RESUMO

With most of the T cells residing in the tissue, not the blood, developing noninvasive methods for in vivo quantification of their biodistribution and kinetics is important for studying their role in immune response and memory. This study presents the first use of dynamic positron emission tomography (PET) and kinetic modeling for in vivo measurement of CD8+ T cell biodistribution in humans. A 89Zr-labeled CD8-targeted minibody (89Zr-Df-Crefmirlimab) was used with total-body PET in healthy individuals (N = 3) and coronavirus disease 2019 (COVID-19) convalescent patients (N = 5). Kinetic modeling results aligned with T cell-trafficking effects expected in lymphoid organs. Tissue-to-blood ratios from the first 7 hours of imaging were higher in bone marrow of COVID-19 convalescent patients compared to controls, with an increasing trend between 2 and 6 months after infection, consistent with modeled net influx rates and peripheral blood flow cytometry analysis. These results provide a promising platform for using dynamic PET to study the total-body immune response and memory.


Assuntos
COVID-19 , Humanos , Distribuição Tecidual , COVID-19/diagnóstico por imagem , Tomografia por Emissão de Pósitrons/métodos , Linfócitos T CD8-Positivos , Zircônio , Linhagem Celular Tumoral
20.
J Nucl Med ; 64(7): 1145-1153, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37290795

RESUMO

We introduce the Fast Algorithm for Motion Correction (FALCON) software, which allows correction of both rigid and nonlinear motion artifacts in dynamic whole-body (WB) images, irrespective of the PET/CT system or the tracer. Methods: Motion was corrected using affine alignment followed by a diffeomorphic approach to account for nonrigid deformations. In both steps, images were registered using multiscale image alignment. Moreover, the frames suited to successful motion correction were automatically estimated by calculating the initial normalized cross-correlation metric between the reference frame and the other moving frames. To evaluate motion correction performance, WB dynamic image sequences from 3 different PET/CT systems (Biograph mCT, Biograph Vision 600, and uEXPLORER) using 6 different tracers (18F-FDG, 18F-fluciclovine, 68Ga-PSMA, 68Ga-DOTATATE, 11C-Pittsburgh compound B, and 82Rb) were considered. Motion correction accuracy was assessed using 4 different measures: change in volume mismatch between individual WB image volumes to assess gross body motion, change in displacement of a large organ (liver dome) within the torso due to respiration, change in intensity in small tumor nodules due to motion blur, and constancy of activity concentration levels. Results: Motion correction decreased gross body motion artifacts and reduced volume mismatch across dynamic frames by about 50%. Moreover, large-organ motion correction was assessed on the basis of correction of liver dome motion, which was removed entirely in about 70% of all cases. Motion correction also improved tumor intensity, resulting in an average increase in tumor SUVs by 15%. Large deformations seen in gated cardiac 82Rb images were managed without leading to anomalous distortions or substantial intensity changes in the resulting images. Finally, the constancy of activity concentration levels was reasonably preserved (<2% change) in large organs before and after motion correction. Conclusion: FALCON allows fast and accurate correction of rigid and nonrigid WB motion artifacts while being insensitive to scanner hardware or tracer distribution, making it applicable to a wide range of PET imaging scenarios.


Assuntos
Movimento (Física) , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Automação , Imagem Corporal Total/métodos , Fatores de Tempo , Humanos , Software , Neoplasias/diagnóstico por imagem