1.
Anal Chem ; 96(4): 1462-1467, 2024 01 30.
Artigo em Inglês | MEDLINE | ID: mdl-38211954

RESUMO

While the combination of liquid chromatography (LC) and mass spectrometry (MS) serves as a robust approach for oligosaccharide analysis, it has difficulty distinguishing the smallest differences between isomers. The integration of infrared (IR) spectroscopy within a mass spectrometer as an additional analytical dimension can effectively address this limitation by providing a molecular fingerprint that is unique to each isomer. However, the direct interfacing of LC-MS with IR spectroscopy presents a technical challenge arising from the mismatch in the operational time scale of each method. In previous studies, this temporal incompatibility was mitigated by employing strategies designed to slow down or broaden the LC elution peaks of interest, but this workaround is applicable only for a few species at a time, necessitating multiple LC runs for comprehensive analysis. In the current work, we directly couple LC with cryogenic IR spectroscopy by acquiring a spectrum in as little as 10 s. This allows us to generate an orthogonal data dimension for molecular identification in the same amount of time that it normally takes for LC analysis. We successfully demonstrate this approach on a commercially available human milk oligosaccharide product, acquiring spectral information on the eluting peaks in real time and using it to identify both the specified constituents and nonspecified product impurities.


Assuntos
Oligossacarídeos , Humanos , Cromatografia Líquida , Espectrometria de Massas/métodos , Isomerismo , Espectrofotometria Infravermelho , Oligossacarídeos/química
2.
Anal Chem ; 95(25): 9623-9629, 2023 Jun 27.
Artigo em Inglês | MEDLINE | ID: mdl-37307499

RESUMO

The high isomeric complexity of glycans makes them particularly difficult to analyze. While ultra-high-resolution ion mobility spectrometry (IMS) can offer rapid baseline separation of many glycan isomers, their unambiguous identification remains a challenging task. One approach to solving this problem is to identify mobility-separated isomers by measuring their highly resolved cryogenic vibrational spectra. To be able to apply this approach to complex mixtures at high throughput, we have recently developed a Hadamard transform multiplexed spectroscopic technique that allows measuring vibrational spectra of all species separated in both IMS and mass spectrometry dimensions in a single laser scan. In the current work, we further develop the multiplexing technique using ion traps incorporated directly into the IMS device based on structures for lossless ion manipulations (SLIM). We also show that multiplexed spectroscopy using perfect sequence matrices can outperform standard multiplexing using Simplex matrices. Lastly, we show that we can increase the measurement speed and throughput further by running multiple multiplexing schemes using several SLIM ion traps in combination with simultaneous spectroscopic measurements in the segmented cryogenic ion trap.

3.
Anal Chem ; 95(18): 7118-7126, 2023 05 09.
Artigo em Inglês | MEDLINE | ID: mdl-37119183

RESUMO

The structural elucidation of metabolite molecules is important in many branches of the life sciences. However, the isomeric and isobaric complexity of metabolites makes their identification extremely challenging, and analytical standards are often required to confirm the presence of a particular compound in a sample. We present here an approach to overcome these challenges using high-resolution ion mobility spectrometry in combination with cryogenic vibrational spectroscopy for the rapid separation and identification of metabolite isomers and isobars. Ion mobility can separate isomeric metabolites in tens of milliseconds, and cryogenic IR spectroscopy provides highly structured IR fingerprints for unambiguous molecular identification. Moreover, our approach allows one to identify metabolite isomers automatically by comparing their IR fingerprints with those previously recorded in a database, obviating the need for a recurrent introduction of analytical standards. We demonstrate the principle of this approach by constructing a database composed of IR fingerprints of eight isomeric/isobaric metabolites and use it for the identification of these isomers present in mixtures. Moreover, we show how our fast IR fingerprinting technology allows to probe the IR fingerprints of molecules within just a few seconds as they elute from an LC column. This approach has the potential to greatly improve metabolomics workflows in terms of accuracy, speed, and cost.


Assuntos
Espectrometria de Mobilidade Iônica , Metabolômica , Metabolômica/métodos , Isomerismo , Bases de Dados Factuais
4.
Analyst ; 148(10): 2277-2282, 2023 May 16.
Artigo em Inglês | MEDLINE | ID: mdl-37098888

RESUMO

High-resolution ion mobility spectrometry (IMS) coupled with cryogenic infrared spectroscopy has proven to be a powerful technique for the identification of oligosaccharides. However, the need for an extensive database, combined with the scarcity of pure standards, remains a significant barrier to the broad application of this approach. To solve this issue, we demonstrate a method in which ion fragments produced by collision-induced dissociation (CID) are separated using IMS and identified using the vibrational fingerprints of only a few standards. Identification of the fragments allows us to determine the structure of the precursor molecule, the vibrational fingerprint of which is then added to our database. We then show how we can use this approach to identify the structure of mobility separated isomers found in pooled human milk.


Assuntos
Espectrometria de Mobilidade Iônica , Leite Humano , Humanos , Espectrometria de Mobilidade Iônica/métodos , Leite Humano/química , Oligossacarídeos/análise , Isomerismo , Espectrofotometria Infravermelho
5.
Anal Chem ; 94(6): 2912-2917, 2022 02 15.
Artigo em Inglês | MEDLINE | ID: mdl-35113536

RESUMO

Coupling vibrational ion spectroscopy with high-resolution ion mobility separation offers a promising approach for detailed analysis of biomolecules in the gas phase. Improvements in the ion mobility technology have made it possible to separate isomers with minor structural differences, and their interrogation with a tunable infrared laser provides vibrational fingerprints for unambiguous database-enabled identification. Nevertheless, wide analytical application of this technique requires high-throughput approaches for acquisition of vibrational spectra of all species present in complex mixtures. In this work, we present a novel multiplexed approach and demonstrate its utility for cryogenic ion spectroscopy of peptides and glycans in mixtures. Since the method is based on Hadamard transform multiplexing, it yields infrared spectra with an increased signal-to-noise ratio compared to a conventional signal averaging approach.


Assuntos
Polissacarídeos , Isomerismo , Razão Sinal-Ruído , Espectrofotometria Infravermelho
6.
Anal Chem ; 93(44): 14730-14736, 2021 11 09.
Artigo em Inglês | MEDLINE | ID: mdl-34704745

RESUMO

The analysis of glycans presents a significant challenge that arises from their isomeric heterogeneity. While high-resolution ion mobility spectrometry (IMS) has shown the ability to resolve subtly different glycan isomers, their unambiguous assignment remains difficult. Here, we demonstrate an infrared (IR) spectroscopic approach for identifying isomers in a glycan mixture. To display the feasibility of this approach, we have constructed a small database of cryogenic spectra of five lacto-N-fucopentaose (LNFP) and six disaccharide isomers and demonstrated that in the cases where they cannot be separated by IMS, we can use a cryogenic IR spectrum to identify the isomeric components of a mixture.


Assuntos
Leite Humano , Oligossacarídeos , Humanos , Espectrometria de Mobilidade Iônica , Isomerismo , Polissacarídeos
7.
Anal Chem ; 92(13): 9079-9085, 2020 07 07.
Artigo em Inglês | MEDLINE | ID: mdl-32456419

RESUMO

The isomeric heterogeneity of glycans poses a great challenge for their analysis. While combining ion mobility spectrometry (IMS) with tandem mass spectrometry is a powerful means for identifying and characterizing glycans, it has difficulty distinguishing the subtlest differences between isomers. Cryogenic infrared spectroscopy provides an additional dimension for glycan identification that is extremely sensitive to their structure. Our approach to glycan analysis combines ultrahigh-resolution IMS-IMS using structures for lossless ion manipulation (SLIM) with cryogenic infrared spectroscopy. We present here the design of a SLIM board containing a series of on-board traps in which we perform collision-induced dissociation (CID) at pressures in the millibar range. We characterize the on-board CID process by comparing the fragments generated from a pentapeptide to those obtained on a commercial tandem mass spectrometer. We then apply our new technique to study the mobility and vibrational spectra of CID fragments from two human milk oligosaccharides. Comparison of both the fragment drift times and IR spectra with those of suitable reference compounds allows us to identify their specific isomeric form, including the anomericity of the glycosidic linkage, demonstrating the power of this tool for glycan analysis.


Assuntos
Espectrometria de Mobilidade Iônica/métodos , Polissacarídeos/análise , Humanos , Espectrometria de Mobilidade Iônica/normas , Isomerismo , Leite Humano/metabolismo , Oligossacarídeos/análise , Oligossacarídeos/normas , Polissacarídeos/normas , Padrões de Referência , Espectrofotometria Infravermelho/normas , Espectrometria de Massas em Tandem
8.
Analyst ; 145(20): 6493-6499, 2020 Oct 21.
Artigo em Inglês | MEDLINE | ID: mdl-32749397

RESUMO

Glycans covalently attached to protein biotherapeutics have a significant impact on their biological activity, clearance, and safety. As a result, glycosylation is categorized as a critical quality attribute that needs an adequate analytical approach to guarantee product quality. However, the isomeric complexity and branched structure of glycans makes their analysis a significant challenge. In this work, we propose a multidimensional approach for monitoring released glycans that combines ultrahigh-resolution ion mobility spectrometry (IMS) and cryogenic vibrational spectroscopy, and we demonstrate this technique by characterizing four N-glycans cleaved from the therapeutic fusion protein etanercept that range in abundance from 1% to 22% of the total N-glycan content. The recorded vibrational spectra exhibit well-resolved transitions that can be used as a fingerprint to identify a particular glycan. This work represents an important advance in the analysis of N-linked glycans cleaved from biopharmaceutical proteins that could eventually be used as tool for monitoring biopharmaceutical glycoforms.


Assuntos
Espectrometria de Mobilidade Iônica , Polissacarídeos , Glicosilação , Isomerismo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA