RESUMO
The mechanical properties of biological tissues are fingerprints of certain pathologic processes. Ultrasound systems have been used as a non-invasive technique to both induce kilohertz-frequency mechanical vibrations and detect waves resulting from interactions with biological structures. However, existing methodologies to produce kilohertz-frequency mechanical vibrations using ultrasound require the use of variable-frequency, dual-frequency and high-power systems. Here, we propose and demonstrate the use of bursts of megahertz- frequency acoustic radiation to observe kilohertz-frequency mechanical responses in biological tissues. Femoral bones were obtained from 10 healthy mice and 10 mice in which osteoporosis had been induced. The bones' porosity, trabecular number, trabecular spacing, connectivity and connectivity density were determined using micro-computed tomography (µCT). The samples were irradiated with short, focused acoustic radiation pulses (fâ¯=â¯3.1 MHz, tâ¯=â¯15 µs), and the low-frequency acoustic response (1-100 kHz) was acquired using a dedicated hydrophone. A strong correlation between the spectral maps of the acquired signals and the µCT data was found. In a subsequent evaluation, soft tissue stiffness measurements were performed with a gel wax-based tissue-mimicking phantom containing three spherical inclusions of the same type of gel but different densities and Young's moduli, yet with approximately the same echogenicity. Conventional B-mode ultrasound was unable to image the inclusions, while the novel technique proposed here showed good image contrast.
Assuntos
Fêmur/diagnóstico por imagem , Osteoporose/diagnóstico por imagem , Ondas Ultrassônicas , Ultrassonografia/métodos , Animais , Osso Esponjoso/diagnóstico por imagem , Módulo de Elasticidade , Camundongos , Imagens de Fantasmas , Porosidade , Som , Microtomografia por Raio-XRESUMO
BACKGROUND: Vibro-acoustography (VA) uses two co-focused ultrasound beams with slightly different frequencies. The beams interact and generate a low-frequency focus to excite an object. METHODS: A two-element confocal ultrasound transducer with central frequency at 3.2 MHz was used to generate the low-frequency excitation (30 kHz) and the response of the bone to that excitation was acquired by a dedicated hydrophone. The face of the confocal transducer was positioned parallel to the surface of the bone at a focal length of 7 cm. The hydrophone was fixed to the side of the transducer, out of the path of the ultrasonic beam. RESULTS: The resulting image clearly showed the bone fracture with resolution of 0.25 mm and high contrast with well-defined borders. CONCLUSIONS: In this paper, we present preliminary results of VA imaging of bone surface and of bone fracture using an experimental set-up. Our results encourage future studies using VA to evaluate bone fractures.