Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 82
Filtrar
1.
BMC Cardiovasc Disord ; 24(1): 68, 2024 Jan 23.
Artigo em Inglês | MEDLINE | ID: mdl-38262995

RESUMO

BACKGROUND: The residual burden of coronary artery disease (CAD) after percutaneous coronary intervention (PCI) drew a growing interest. The residual SYNTAX Score (rSS) was a strong prognostic factor of adverse events and all-cause mortality in patients who underwent PCI. In addition, the SYNTAX Revascularization Index (SRI), a derivative of rSS, was used to figure out the treated proportion of CAD and could be used as a prognostic utility in PCI for patients with multi-vessel disease (MVD). PURPOSE: We aimed at the assessment of the use of rSS and the SRI as predictors of in-hospital outcomes and up to two-year cumulative follow-up outcomes in patients with MVD who had PCI for the treatment of ST-Elevation Myocardial Infarction (STEMI) or Non-STEMI (NSTEMI). METHODS: We recruited 149 patients who had either STEMI or NSTEMI while having MVD and received treatment with PCI. We divided them into tertiles based on their rSS and SRI values. We calculated baseline SYNTAX Score (bSS) and rSS using the latest version of the calculator on the internet, and we used both scores to calculate SRI. The study end-points were In-hospital composite Major Adverse Cardiovascular Events (MACE) and its components, in-hospital death, and follow-up cumulative MACE up to 2 years. RESULTS: Neither rSS nor SRI were significant predictors of in-hospital adverse events, while female sex, hypertension, and left ventricular ejection fraction were independent predictors of in-hospital MACE. At the two-year follow-up, Kaplan-Meyer analysis showed a significantly increased incidence of MACE within the third rSS tertile (rSS > 12) compared to other tertiles (log rank p = 0.03). At the same time, there was no significant difference between the three SRI tertiles. Unlike SRI, rSS was a significant predictor of cumulative MACE on univariate Cox regression (HR = 1.037, p < 0.001). On multivariate Cox regression, rSS was a significant independent predictor of two-year cumulative MACE (HR = 1.038, p = 0.0025) along with female sex, hypertension, and left ventricular ejection fraction. We also noted that all patients with complete revascularization survived well throughout the entire follow-up period. CONCLUSIONS: Neither rSS nor SRI could be good predictors of in-hospital MACE, while the rSS was a good predictor of MACE at two-year follow-up. Patients with rSS values > 12 had a significantly higher incidence of cumulative MACE after 2 years. The best prognosis was achieved with complete revascularization.


Assuntos
Doença da Artéria Coronariana , Hipertensão , Infarto do Miocárdio , Infarto do Miocárdio sem Supradesnível do Segmento ST , Intervenção Coronária Percutânea , Infarto do Miocárdio com Supradesnível do Segmento ST , Humanos , Feminino , Mortalidade Hospitalar , Volume Sistólico , Função Ventricular Esquerda
2.
J Cardiovasc Electrophysiol ; 33(5): 1034-1040, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35243712

RESUMO

INTRODUCTION: We hypothesized that an accurate assessment of preoperative venography could be useful in predicting transvenous lead extraction (TLE) difficulty. METHODS AND RESULTS: A dedicated preoperative venogram was performed in consecutive patients with cardiac implantable electronic device who underwent TLE. The level of stenosis was classified as without significant stenosis, moderate, severe, and occlusion. The presence of extensive lead-venous wall adherence (≥50 mm) was also assessed. A total of 105 patients (median age: 71 years; 72% male) with a median of 2 (1-2) leads to extract were enrolled. Preoperative venography showed moderate to severe stenosis in 31 (30%), complete occlusion in 15 (14%), and extensive lead-venous wall adherence in 50 (48%) patients. Complete TLE success was achieved in 103 (98%) patients. A total of 55 (52%) were advanced extractions as they required a powered mechanical and/or laser sheath. They were more prevalent in the group with extensive lead-venous wall adherence (72% vs. 34%, p < .001), while no differences were found between patients with and without venous occlusion. In multivariate analysis, the presence of adherence was a predictor of advanced extraction (odds ratio: 2.89 [1.14-7.32], p = .025). The fluoroscopy time was also significantly longer (14.0 [8.2-18.7] vs. 5.1 [2.1-10.0] min, p < .001). The rate of complications did not differ based on the presence of venous lesions. CONCLUSION: Although procedural success and complication rates were similar, patients with extensive lead-venous wall adherence required a longer fluoroscopy time and were three times more likely to need advanced extraction tools. Conversely, the presence of total venous occlusion had no impact on the procedure complexity.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Doenças Vasculares , Idoso , Constrição Patológica , Remoção de Dispositivo/efeitos adversos , Remoção de Dispositivo/métodos , Feminino , Humanos , Masculino , Flebografia , Estudos Retrospectivos , Resultado do Tratamento
3.
Am J Emerg Med ; 50: 413-421, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34481261

RESUMO

BACKGROUND: One promising biomarker that has received substantial interest for the evaluation of suspected acute coronary syndromes (ACS) is copeptin. Therefore, our goal was to assess the additive value of copeptin for early diagnosis and prognosis of Non-ST segment acute coronary syndromes (NSTE-ACS). METHODS: The study included ninety patients with suspected ACS. Patients with typical ischemic chest pain within six hours of symptom onset and without ST-segment elevation on electrocardiograph (ECG) were included. In addition to cardiac troponin I (cTnI), copeptin was assayed from venous blood samples obtained on admission, followed by serial troponin measurements six and twelve hours later. One year follow-up was performed for any major adverse cardiac events (MACEs) including cardiac death, re-infarction, re- hospitalization for ischemic events, heart failure, stroke and target lesion revascularization (TLR). RESULTS: Of seventy nine patients included in the final analysis, Forty (50.6%) were diagnosed as unstable angina (UA), while thirty nine (49.4%) had a non-ST elevation myocardial infarction (NSTEMI). Copeptin level on admission was significantly higher among NSTEMI patients than those with UA. With regard to the correlation analyses, copeptin was positively correlated with each of, Global Registry of Acute Coronary Events (GRACE), Thrombolysis In Myocardial Infarction (TIMI) and synergy between percutaneous coronary intervention with taxus and cardiac surgery (SYNTAX) scores. The sensitivity and negative predictive value (NPV) of the combination of admission copeptin and cTn-I were 100% and 100%, respectively, versus 57% and 70%, respectively, with admission of cTn-I alone. The area under curve (AUC) of the combination of copeptin and cTn-I was (0.975, p < 0.001) and was significantly higher than the AUC of cTn-I alone (0.888, p < 0.001). Admission copeptin was an independent predictor for MACEs by multiple regression analysis (OR: 0.01, 95% CI: 0.0-0.8, P = 0.04). High values of copeptin had the highest rate of MACEs and coronary revascularization during one year of follow up. CONCLUSION: The combination of copeptin and conventional troponin I aids in early rule out of NSTEMI virtually independent of chest pain onset (CPO) with high NPV in patients presenting within three hours from chest pain onset with excellent prognostic value for risk stratification and prediction of MACEs.


Assuntos
Síndrome Coronariana Aguda/diagnóstico , Glicopeptídeos/sangue , Biomarcadores/sangue , Diagnóstico Precoce , Eletrocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Estudos Prospectivos , Troponina/sangue
4.
AAPS PharmSciTech ; 21(6): 223, 2020 Aug 04.
Artigo em Inglês | MEDLINE | ID: mdl-32749629

RESUMO

This study aimed to enhance the dissolution of simvastatin (SMV) through its formulation in liquisolid tablets (LSTs) to improve its bioavailability and hypolipidemic activity after oral administration. SMV-LSTs were optimized using Box-Behnken design to maximize the rate and extent of SMV dissolution. The optimized SMV-LST was evaluated for pharmacokinetic parameters and potential hypolipidemic activity on induced hyperlipidemic rats. The dissolution parameters revealed a shortening of mean dissolution time from 10.99 to 6.82 min, increasing of dissolution rate during the first 10 min from 1253.15 to 1667.31 µg/min, and enhancing of dissolution efficiency after 60 min from 71.92 to 86.93% for SMV-LSTs versus the commercial SMV tablets. The obtained data reflected an improvement in the relative bioavailability of SMV with 148.232% which was confirmed by the significant reduction of the levels of circulating total cholesterol, triglycerides that reached the normal level after 12 h. In particular, the optimized SMV-LSTs reduced serum low-density lipoproteins (LDL) by 44.6% which was significantly different from the commercial SMV tablets. In contrast, the level of serum high-density lipoprotein (HDL) was significantly augmented after 4 h in rats treated with the optimized SMV-LSTs by 47.6%. Finally, the optimized SMV-LSTs showed a significant lower atherosclerotic index value which could maximize its potential in decreasing the risk of coronary disease and atherosclerosis. Overall enhancement in pharmacokinetics and pharmacodynamics in comparison with the commercial tablets confers the potential of the liquisolid approach as a promising alternative for improved oral bioavailability, hypolipidemic, and cardioprotective effects of SMV. Graphical abstract.


Assuntos
Hipolipemiantes/farmacologia , Sinvastatina/farmacologia , Animais , Disponibilidade Biológica , Masculino , Poloxâmero/toxicidade , Ratos , Ratos Wistar , Sinvastatina/química , Sinvastatina/farmacocinética , Solubilidade , Comprimidos
5.
BMC Med ; 17(1): 197, 2019 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-31672136

RESUMO

BACKGROUND: Dyslipidemia and inflammation are closely interrelated contributors in the pathogenesis of atherosclerosis. Disorders of lipid metabolism initiate an inflammatory and immune-mediated response in atherosclerosis, while low-density lipoprotein cholesterol (LDL-C) lowering has possible pleiotropic anti-inflammatory effects that extend beyond lipid lowering. MAIN TEXT: Activation of the immune system/inflammasome destabilizes the plaque, which makes it vulnerable to rupture, resulting in major adverse cardiac events (MACE). The activated immune system potentially accelerates atherosclerosis, and atherosclerosis activates the immune system, creating a vicious circle. LDL-C enhances inflammation, which can be measured through multiple parameters like high-sensitivity C-reactive protein (hsCRP). However, multiple studies have shown that CRP is a marker of residual risk and not, itself, a causal factor. Recently, anti-inflammatory therapy has been shown to decelerate atherosclerosis, resulting in fewer MACE. Nevertheless, an important side effect of anti-inflammatory therapy is the potential for increased infection risk, stressing the importance of only targeting patients with high residual inflammatory risk. Multiple (auto-)inflammatory diseases are potentially related to/influenced by LDL-C through inflammasome activation. CONCLUSIONS: Research suggests that LDL-C induces inflammation; inflammation is of proven importance in atherosclerotic disease progression; anti-inflammatory therapies yield promise in lowering (cardiovascular) disease risk, especially in selected patients with high (remaining) inflammatory risk; and intriguing new anti-inflammatory developments, for example, in nucleotide-binding leucine-rich repeat-containing pyrine receptor inflammasome targeting, are currently underway, including novel pathway interventions such as immune cell targeting and epigenetic interference. Long-term safety should be carefully monitored for these new strategies and cost-effectiveness carefully evaluated.


Assuntos
Aterosclerose/imunologia , LDL-Colesterol/imunologia , Inflamação/imunologia , Anti-Inflamatórios/uso terapêutico , Aterosclerose/prevenção & controle , Biomarcadores , Proteína C-Reativa/imunologia , Humanos , Inflamação/prevenção & controle
6.
Ann Noninvasive Electrocardiol ; 24(4): e12637, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-30737993

RESUMO

BACKGROUND: Arrhythmias are considered one of the major causes of death in ST elevation myocardial infarction (STEMI), particularly in the early in-hospital phase. Pre-infarction angina (PIA) has been suggested to have a protective role. OBJECTIVES: To study the difference in acute electrocardiographic findings between STEMI patients with and without PIA and to assess the in-hospital arrhythmias in both groups. MATERIAL AND METHODS: We prospectively enrolled 238 consecutive patients with STEMI. Patients were divided into two groups: those with or without PIA. ECG data recorded and analyzed included ST-segment resolution (STR) at 90 min, corrected QT interval (QTc) and dispersion (QTD), T-peak-to-T-end interval (Tp-Te), and dispersion and Tp-Te/QT ratio. In-hospital ventricular arrhythmias encountered in both groups were recorded. Predictors of in-hospital arrhythmias were assessed among different clinical and electrocardiographic parameters. RESULTS: Of the 238 patients included, 42 (17%) had PIA and 196 (83%) had no PIA. Patients with PIA had higher rates of STR (p < 0.0001), while patients with no PIA had higher values of QTc (p = 0.006), QTD (p = 0.001), Tp-Te interval (p = 0.001), Tp-Te dispersion (p < 0.0001), and Tp-Te/QT ratio (p = 0.01) compared to those with angina preceding their incident infarction (PIA). This was reflected into significantly higher rates of in-hospital arrhythmias among patients with no PIA (20% vs. 7%, p = 0.04). Furthermore, longer Tp-Te interval and higher Tp-Te/QT ratio independently predicted in-hospital ventricular arrhythmias. CONCLUSION: Pre-infarction angina patients had better electrocardiographic measures of repolarization dispersion and encountered significantly less arrhythmic events compared to patients who did not experience PIA.


Assuntos
Angina Pectoris/fisiopatologia , Arritmias Cardíacas/fisiopatologia , Eletrocardiografia/métodos , Ventrículos do Coração/fisiopatologia , Intervenção Coronária Percutânea/métodos , Infarto do Miocárdio com Supradesnível do Segmento ST/fisiopatologia , Infarto do Miocárdio com Supradesnível do Segmento ST/terapia , Angina Pectoris/complicações , Angina Pectoris/terapia , Arritmias Cardíacas/complicações , Arritmias Cardíacas/terapia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Infarto do Miocárdio com Supradesnível do Segmento ST/complicações
7.
Drug Dev Ind Pharm ; 44(1): 66-81, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28831818

RESUMO

OBJECTIVE: Implementation of a new pharmaceutical technique to improve aqueous solubility and thus dissolution, enhancement of drug permeation, and finally formulation of a controlled release tablet loaded with glimepiride (GLMP). SIGNIFICANCE: Improve GLMP bioavailability and pharmacokinetics in type II diabetic patients. METHODS: Different polymers were used to enhance aqueous GLMP solubility of which a saturated polymeric drug solution was prepared and physically adsorbed onto silica. An experimental design was employed to optimize the formulation parameters affecting the preparation of GLMP matrix tablets. A compatibility study was conducted to study components interactions. Scanning electron microscope (SEM) was performed before and after the tablets were placed in the dissolution medium. An in vivo study in human volunteers was performed with the optimized GLMP tablets, which were compared to pure and marketed drug products. RESULTS: Enhancement of GLMP aqueous solubility, using the polymeric drug solution technique, by more than 6-7 times when compared with the binary system. All the studied formulation factors significantly affected the studied variables. No significant interaction was detected among components. SEM illustrated the surface and inner tablet structure, and confirmed the drug release which was attributed to diffusion mechanism. The volunteer group administered the optimized GLMP tablet exhibited higher drug plasma concentration (147.4 ng/mL), longer time to reach maximum plasma concentration (4 h) and longer t1/2 (7.236 h) compared to other groups. CONCLUSIONS: Matrix tablet loaded with a physically modified drug form could represent a key solution for drugs with inconsistent dissolution and absorption profiles.


Assuntos
Química Farmacêutica/métodos , Polímeros/química , Compostos de Sulfonilureia/farmacocinética , Disponibilidade Biológica , Solubilidade , Compostos de Sulfonilureia/química , Comprimidos
8.
Drug Dev Ind Pharm ; 44(4): 652-661, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29139305

RESUMO

OBJECTIVE: Preparation of an optimized finasteride (FSD) lyophilized tablets loaded with self-nanoemulsifying drug delivery system (SNEDDS). SIGNIFICANCE: Enhance FSD bioavailability in male pattern baldness and benign prostatic hyperplasia. METHODS: Two-step optimization was implemented to achieve the study goals. First; the mixture design was used to develop an optimized SNEDDS through which the effect of cosurfactant number of carbon atoms on SNEDDS particle size and thermodynamic stability has been tested. Second; the different tablet excipients have been used to develop an optimized self-nanoemulsifying lyophilized tablets (SNELTs). The prepared tablets have been fully characterized. Interaction among tablet components has been studied. Finally, FSD clinical pharmacokinetic has been investigated on human volunteers. RESULTS: Anise oil and tween 80 were selected as oily phase and surfactant, respectively while different aliphatic alcohols were studied as cosurfactants. Percentages of oil, surfactant, and cosurfactants were significantly affecting SNEDDS particle size. Increasing cosurfactant number of carbon atoms achieved smaller particle size and higher stability. The optimized SNEDDS was found to contain 10.3455, 45.8972, and 43.7573% of anise oil, tween 80, and butanol, respectively. Variations in FSD cumulative release and disintegration time, from the prepared tablets, were attributed to change in the percent of plasdone XL, Avicel and silica. No interaction among components was noticed. Clinical pharmacokinetics illustrated significant enhancement in the studied parameters from the optimized lyophilized tablets loaded with drug SNEDDS when compared to marketed FSD product. CONCLUSION: Lyophilized tablets could be considered as a good alternative for conventional solid dosage forms especially when loaded with drug nanosystems.


Assuntos
Finasterida/administração & dosagem , Finasterida/farmacocinética , Comprimidos , Adulto , Alopecia/tratamento farmacológico , Disponibilidade Biológica , Composição de Medicamentos , Sistemas de Liberação de Medicamentos , Desenho de Fármacos , Estabilidade de Medicamentos , Emulsões , Finasterida/química , Liofilização , Humanos , Masculino , Nanopartículas , Óleos , Polissorbatos , Solubilidade , Termodinâmica , Adulto Jovem
9.
J Liposome Res ; 26(4): 288-96, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26784833

RESUMO

CONTEXT: Avanafil (AVA) is used in the treatment of erectile dysfunction, but is reported for its poor aqueous solubility. Solid lipid nanoparticles (SLNs) are lipid carriers that can greatly enhance drug solubility and bioavailability. OBJECTIVE: This work was aimed to formulate and optimize AVA SLNs with subsequent loading into hydrogel films for AVA transdermal delivery. MATERIALS AND METHODS: AVA SLNs were prepared utilizing homogenization followed by ultra-sonication technique. The prepared SLNs were characterized for particle size, charge, surface morphology and drug content. The optimized SLNs formulation was incorporated into transdermal films prepared using HPMC and chitosan. Hydrogel films were evaluated for ex-vivo rat skin permeation using automated Franz diffusion cells. The permeation parameters and the release mechanism were evaluated. The transdermal permeation of the prepared AVA SLNs through the skin layers was studied using confocal laser scanning microscope. RESULTS: Lipid concentration and % of oil in lipid had a pronounced effect on particle size while, entrapment efficiency was significantly affected by lipid concentration and % of cholesterol. The optimized AVA SLNs showed particle size and entrapment efficiency of 86 nm and 85.01%, respectively. TEM images revealed spherecity of the particles. High permeation parameters were observed from HPMC films loaded with AVA SLNs. The release data were in favor of Higuchi diffusion model. The prepared AVA SLNs were able to penetrate deeper in skin layers. CONCLUSION: HPMC transdermal film-loaded AVA SLNs is an effective and alternative to per-oral drug administration.


Assuntos
Sistemas de Liberação de Medicamentos , Lipídeos/química , Nanopartículas/química , Pirimidinas/administração & dosagem , Pirimidinas/farmacocinética , Administração Cutânea , Animais , Disponibilidade Biológica , Química Farmacêutica , Tamanho da Partícula , Ratos , Ratos Wistar , Pele/química , Pele/metabolismo , Absorção Cutânea , Solubilidade , Propriedades de Superfície
10.
J Liposome Res ; 25(1): 1-10, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25148294

RESUMO

The aim of this work was to study the effect of different processing and formulation parameters on the preparation of sildenafil (SD) transfersomes utilizing the Plackett-Burman design. The drug to phospholipid molar ratio (X1), phospholipid to surfactant ratio (X2), hydrophilic-lipophilic balance of the surfactant (X3), hydration medium pH (X4), hydration time (X5) and the temperature of hydration (X6) were investigated to study their effect on the vesicle size (Y1) and entrapment efficiency (EE) of the drug (Y2). The preparation conditions were optimized to minimize the vesicle size and maximize the EE. The prepared transfersomes were also subjected to zeta potential measurements, morphological and physicochemical characterization. The combinations of factors that achieve the optimum desirability were identified. An optimized formulation was prepared and characterized once more for its vesicle size, EE, in vitro permeation and deformability index. The results revealed that both X3 and X6 had a pronounced effect on Y1, while X1 and X4 showed a significant effect on Y2. Morphological and physicochemical study confirmed the transfersomes spherical shape and compatibility of the formulation ingredients. The formulation with optimum desirability showed EE and vesicle size of 97.21% and 610 nm, respectively. In vitro permeation of the drug-loaded transfersome showed more than 5-fold higher permeation rate compared with drug suspension. Deformability index verified elasticity of the preparation. The significant variables could be optimized again to produce smaller vesicle size that could increase SD permeation from transdermal delivery systems loaded drug optimized transfersomes.


Assuntos
Inibidores da Fosfodiesterase 5/química , Piperazinas/química , Sulfonamidas/química , Administração Cutânea , Varredura Diferencial de Calorimetria , Química Farmacêutica , Elasticidade , Humanos , Lipossomos , Tamanho da Partícula , Permeabilidade , Inibidores da Fosfodiesterase 5/administração & dosagem , Piperazinas/administração & dosagem , Purinas/administração & dosagem , Purinas/química , Citrato de Sildenafila , Sulfonamidas/administração & dosagem
11.
Pharm Dev Technol ; 20(8): 919-926, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25019166

RESUMO

OBJECTIVE: Detailed optimization process was carried out to enhance permeation parameters, and hence bioavailability, of simvastatin (SMV) transdermal films. METHODS: SMV solubility was investigated in various oils, surfactants and co-surfactants/co-solvents. Mixtures of the selected components were prepared to identify zone of nanoemulsion formation that was utilized in Extreme Vertices mixture design to develop SMV self-nanoemulsifying drug delivery systems (SNEDDS) with minimum globule size. Optimized SMV-SNEDDS were included in the preparation of transdermal films. A fractional factorial design was implemented to evaluate effects of the factors on the amount of SMV permeated. The optimized film was investigated for ex vivo skin permeation and in vivo pharmacokinetic parameters. RESULTS: The optimum SNEDDS formula was 0.09, 0.8 and 0.11 for Sefsol 218, tween 80 and PEG 200, respectively. Fractional factorial design depicted the optimized SMV transdermal film with 2% HPMC and 2% DMSO as permeation enhancer that showed 1.82-fold improvements in skin flux. The pharmacokinetic data showed higher Cmax and almost doubled AUC compared with raw SMV-loaded films. CONCLUSION: The two-step optimization implemented to optimize and control the experimental conditions for the preparation of SMV-SNEDDS-transdermal film with improved ex vivo skin permeation and enhanced in vivo parameters.

12.
Pharm Dev Technol ; 20(6): 738-46, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-24856961

RESUMO

The purpose was to improve the encapsulation efficiency of cetirizine hydrochloride (CTZ) microspheres as a model for water soluble drugs and control its release by applying response surface methodology. A 3(3) Box-Behnken design was used to determine the effect of drug/polymer ratio (X1), surfactant concentration (X2) and stirring speed (X3), on the mean particle size (Y1), percentage encapsulation efficiency (Y2) and cumulative percent drug released for 12 h (Y3). Emulsion solvent evaporation (ESE) technique was applied utilizing Eudragit RS100 as coating polymer and span 80 as surfactant. All formulations were evaluated for micromeritic properties and morphologically characterized by scanning electron microscopy (SEM). The relative bioavailability of the optimized microspheres was compared with CTZ marketed product after oral administration on healthy human volunteers using a double blind, randomized, cross-over design. The results revealed that the mean particle sizes of the microspheres ranged from 62 to 348 µm and the efficiency of entrapment ranged from 36.3% to 70.1%. The optimized CTZ microspheres exhibited a slow and controlled release over 12 h. The pharmacokinetic data of optimized CTZ microspheres showed prolonged tmax, decreased Cmax and AUC0-∞ value of 3309 ± 211 ng h/ml indicating improved relative bioavailability by 169.4% compared with marketed tablets.


Assuntos
Cetirizina/administração & dosagem , Cetirizina/sangue , Preparações de Ação Retardada/química , Antagonistas não Sedativos dos Receptores H1 da Histamina/administração & dosagem , Antagonistas não Sedativos dos Receptores H1 da Histamina/sangue , Resinas Acrílicas/química , Administração Oral , Adulto , Antialérgicos/administração & dosagem , Antialérgicos/sangue , Antialérgicos/química , Cetirizina/química , Estudos Cross-Over , Método Duplo-Cego , Hexoses/química , Antagonistas não Sedativos dos Receptores H1 da Histamina/química , Humanos , Masculino , Solubilidade , Tensoativos/química , Água/química , Adulto Jovem
13.
Drug Dev Ind Pharm ; 40(1): 66-73, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23298324

RESUMO

OBJECTIVE: The focus of this study was to develop and optimize in situ implant formulation of meloxicam by quality by design (QbD) principle for long-term management of musculoskeletal inflammatory disorders. METHODS: The formulation was optimized by Box-Behnken design with polylactide-co-glycolide (PLGA) level (X1), N-methyl pyrrolidone level (X2) and PLGA intrinsic viscosity (X3) as the independent variables and initial burst release of drug (Y1), cumulative release (Y2), and dissolution efficiency (Y3) as the dependent variables. The formulation was physicochemically characterized by scanning electron microscopy (SEM), Fourier transform infrared (FT-IR) spectroscopy and powder X-ray diffraction (PXRD). Pharmacokinetic studies of the optimized formulation were performed on Sprague-Dawley rats. RESULTS: Y1 was significantly affected by X2 and X3. Y2 was affected by X1 and X3 while Y3 was affected by all three independent variables employed in the formulations. Responses for the optimized formulation were in close agreement with the values predicted by the model. SEM photomicrographs indicated uniform gel formulation. No chemical interaction between the components of formulation was observed by FT-IR and meloxicam was found to be present in the amorphous form in the gel matrix as revealed by PXRD. The maximum plasma concentration (Cmax), time to achieve Cmax and area under plasma concentration curve were significantly different from those of the solution formulation used as the control. Plasma concentration of meloxicam was maintained above its IC50 concentration required for COX-2 inhibition for 23 days. CONCLUSION: Meloxicam in situ implant may provide long-term management of inflammatory conditions with improved patient compliance and better therapeutic index.


Assuntos
Anti-Inflamatórios não Esteroides/administração & dosagem , Portadores de Fármacos/química , Ácido Láctico/química , Ácido Poliglicólico/química , Tiazinas/administração & dosagem , Tiazóis/administração & dosagem , Animais , Anti-Inflamatórios não Esteroides/química , Anti-Inflamatórios não Esteroides/farmacocinética , Área Sob a Curva , Química Farmacêutica/métodos , Composição de Medicamentos/métodos , Implantes de Medicamento , Géis , Concentração Inibidora 50 , Masculino , Meloxicam , Microscopia Eletrônica de Varredura , Copolímero de Ácido Poliláctico e Ácido Poliglicólico , Pirrolidinonas/química , Ratos , Ratos Sprague-Dawley , Espectroscopia de Infravermelho com Transformada de Fourier , Tiazinas/química , Tiazinas/farmacocinética , Tiazóis/química , Tiazóis/farmacocinética , Viscosidade , Difração de Raios X
14.
AAPS PharmSciTech ; 15(3): 772-80, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24648158

RESUMO

The objective of this study was to investigate the sustained release of a hydrophilic drug, montelukast (MK), from two biodegradable polymeric drug delivery systems, in situ implant (ISI) and in situ microparticles (ISM). N-Methyl pyrrolidone (NMP), dimethyl sulfoxide (DMSO), triacetin, and ethyl acetate were selected as solvents. The release of 10% (w/v) MK from both systems containing poly-lactic-co-glycolic acid (PLGA) as the biodegradable polymer was compared. Upon contact with the aqueous medium, the PLGA in ISI and ISM systems solidified resulting in implants and microparticles, respectively. The in vitro drug release from the ISI system showed marked difference from miscible solvents (NMP and DMSO) than the partially miscible ones (triacetin and ethyl acetate), and the drug release decreased with increased PLGA concentration. In the ISM system, the initial in vitro drug release decreased with decreased ratio of polymer phase to external oil phase. In vivo studies in rats showed that ISM had slower drug release than the drug release from ISI. Also, the ISM system when compared to ISI system had significantly reduced initial burst effect. In vitro as well as the in vivo studies for both ISI and ISM systems showed sustained release of MK. The ISM system is suitable for sustained release of MK over 4-week period with a lower initial burst compared to the ISI system. Stability studies of the ISI and ISM formulations showed that MK is stable in the formulations stored at 4°C for more than 2 years.


Assuntos
Implantes Absorvíveis , Acetatos/administração & dosagem , Ácido Láctico/química , Antagonistas de Leucotrienos/administração & dosagem , Ácido Poliglicólico/química , Quinolinas/administração & dosagem , Acetatos/sangue , Acetatos/química , Acetatos/farmacocinética , Animais , Química Farmacêutica , Ciclopropanos , Dimetil Sulfóxido/química , Implantes de Medicamento , Estabilidade de Medicamentos , Injeções Intramusculares , Antagonistas de Leucotrienos/sangue , Antagonistas de Leucotrienos/química , Antagonistas de Leucotrienos/farmacocinética , Masculino , Tamanho da Partícula , Copolímero de Ácido Poliláctico e Ácido Poliglicólico , Pirrolidinonas/química , Quinolinas/sangue , Quinolinas/química , Quinolinas/farmacocinética , Ratos Sprague-Dawley , Solubilidade , Solventes/química , Sulfetos , Tecnologia Farmacêutica/métodos , Temperatura , Triacetina/química
15.
Curr Pharm Des ; 30(14): 1075-1084, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38532602

RESUMO

BACKGROUND: Due to its volatility, photostability, and gastrointestinal toxicity, Perillyl Alcohol (POH), a monoterpenoid component of various plant species, is a chemotherapeutic drug with insufficient efficacy. Many naturally occurring bioactive compounds have well-known antiproliferative properties, including sefsol, jojoba, tea tree, and moringa oils. OBJECTIVE: This study sought to develop an oil-based Self Nanoemulsifying Drug Delivery System (SNEDDS) using tween 80 as the surfactant and Dimethyl Sulfoxide (DMSO) or Polyethylene Glycol (PEG) 400 as the cosurfactant; the oils were used in a range of 10-20% to boost POH's anticancer efficacy. METHODS: The formulations' size, charge, and impact on the viability of glioma cell lines, ANGM-CSS and A172, were evaluated. RESULTS: The developed SNEDDS formulations ranged from 3 nm to 362 nm in size, with electronegative surface charges between 5.05 and 17.0 mV and polydispersity indices between 0.3 and 1.0. CONCLUSION: The findings indicated that the antiproliferative effect of POH-loaded Nanoemulsion (NE) could be used as a possible anticancer therapy for glioblastoma in vitro, particularly when paired with the tested natural oils. Before asserting that this delivery technique is appropriate for glioblastoma therapy, additional in vitro and in vivo investigations are required.


Assuntos
Antineoplásicos , Proliferação de Células , Glioblastoma , Monoterpenos , Humanos , Glioblastoma/tratamento farmacológico , Glioblastoma/patologia , Proliferação de Células/efeitos dos fármacos , Monoterpenos/farmacologia , Monoterpenos/química , Antineoplásicos/farmacologia , Antineoplásicos/química , Sobrevivência Celular/efeitos dos fármacos , Ensaios de Seleção de Medicamentos Antitumorais , Sistemas de Liberação de Medicamentos , Polissorbatos/química , Polissorbatos/farmacologia , Composição de Medicamentos , Tamanho da Partícula , Relação Dose-Resposta a Droga , Óleos de Plantas/farmacologia , Óleos de Plantas/química , Polietilenoglicóis/química , Polietilenoglicóis/farmacologia , Linhagem Celular Tumoral , Antineoplásicos Fitogênicos/farmacologia , Antineoplásicos Fitogênicos/química , Antineoplásicos Fitogênicos/administração & dosagem , Células Tumorais Cultivadas
16.
Int J Pharm ; 658: 124200, 2024 Jun 10.
Artigo em Inglês | MEDLINE | ID: mdl-38710298

RESUMO

This study aimed to develop oral lipidic hybrids of amikacin sulfate (AMK), incorporating thiolated chitosan as a P-glycoprotein (P-gp) inhibitor to enhance intestinal absorptivity and bioavailability. Three formulations were designed: PEGylated Liposomes, Chitosan-functionalized PEGylated (Chito-PEGylated) Lipidic Hybrids, and Thiolated Chito-PEGylated Lipidic Hybrids. The physical characteristics of nanovesicles were assessed. Ex-vivo permeation and confocal laser scanning microscopy (CLSM) studies were conducted to evaluate the formulations' potential to enhance AMK intestinal permeability. In-vivo pharmacokinetic studies in rats and histological/biochemical investigations assessed the safety profile and oral bioavailability. The AMK-loaded Thiolated Chito-PEGylated Lipidic Hybrids exhibited favorable physical characteristics, higher ex-vivo permeation parameters, and verified P-gp inhibition via CLSM. They demonstrated heightened oral bioavailability (68.62% absolute bioavailability) and a sufficient safety profile. Relative bioavailability was significantly higher (1556.3% and 448.79%) compared to PEGylated Liposomes and Chito-PEGylated Lipidic Hybrids, respectively, indicating remarkable oral AMK delivery with fewer doses, reduced side effects, and enhanced patient compliance.


Assuntos
Amicacina , Antibacterianos , Disponibilidade Biológica , Quitosana , Lipídeos , Lipossomos , Polietilenoglicóis , Animais , Polietilenoglicóis/química , Masculino , Administração Oral , Quitosana/química , Amicacina/farmacocinética , Amicacina/administração & dosagem , Amicacina/química , Lipídeos/química , Antibacterianos/farmacocinética , Antibacterianos/administração & dosagem , Antibacterianos/química , Membro 1 da Subfamília B de Cassetes de Ligação de ATP/antagonistas & inibidores , Membro 1 da Subfamília B de Cassetes de Ligação de ATP/metabolismo , Ratos , Ratos Sprague-Dawley , Absorção Intestinal , Compostos de Sulfidrila/química , Compostos de Sulfidrila/farmacocinética , Ratos Wistar
18.
Pharmaceutics ; 15(7)2023 Jul 07.
Artigo em Inglês | MEDLINE | ID: mdl-37514087

RESUMO

6-Mercaptopurine (6-MP) is a chemotherapeutic agent with inadequate efficacy due to its poor aqueous solubility and limited bioavailability. Turmeric oil is a naturally occurring bioactive substance obtained from the rhizomes of Curcuma longa Linn that has well-known antiproliferative activities. The aim of this study was to develop a 6-MP-loaded turmeric oil-based self-nanoemulsifying drug delivery system (SNEDDS) to improve the anticancer activity of 6-MP. Turmeric oil was extracted and used in a range of 15-25% to develop SNEDDS formulations utilizing tween 80 and dimethyl sulfoxide as the surfactant and cosurfactant, respectively. The size, charge, and effect of the formulations on the viability against HepG2 and MCF-7 cell models, as well as the apoptosis and cell cycle, were analyzed. The prepared SNEDDS formulations were in the size range of 425.7 ± 7.4-303.6 ± 19.3 nm, using a polydispersity index of 0.429-0.692 and electronegative surface charges. Moreover, 6-MP-loaded SNEDDS with 15% turmeric oil content (F1) showed smaller particle sizes and a noticeable antiproliferative activity against both cell line models. Also, F1 showed a higher rate of late apoptosis than the pure drug and the corresponding non-medicated formulation. A morphological study revealed significant changes in the HepG2 cells compared to untreated cells. More cells halted in the S phase, and a marked decrease in the proportions of cells in the G1/G0 phase was observed when using SNEDDS formulation compared to pure drug. Thus, SNEDDS formulation is a promising drug delivery system for improving the antiproliferative activity of 6-MP, especially when turmeric oil is incorporated.

19.
Int J Cardiovasc Imaging ; 39(3): 607-620, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36471104

RESUMO

Acute ST-segment elevation myocardial infarction (STEMI) is associated with left ventricular (LV) structural and functional consequences. We aimed to elucidate LV geometric changes following STEMI using three-dimensional (3D) echocardiography (3DE) and to assess their functional implications using two-dimensional (2D) speckle tracking echocardiography (STE). The study included 71 patients with STEMI who underwent baseline and 6-month follow-up 2D- and 3DE. Measured parameters included LV dimensions, biplane volumes, wall motion assessment, 2D LV global longitudinal strain (GLS), and 3D LV volumes, sphericity index and systolic dyssynchrony index. According to 3DE, LV geometric changes were classified as, adverse remodeling, reverse remodeling, and minimal LV volumetric changes. The occurrence of in-hospital and follow-up major adverse cardiovascular events (MACE) was assessed among the study population. The incidence of developing adverse remodeling was 25.4% while that of reverse remodeling was 36.6%. Adverse remodeling patients had significantly higher in-hospital MACE. Reverse remodeling was associated with significantly improved GLS, that was less evident in those with minimal LV geometric changes, and non-significant improvement for adverse remodeling group. LV baseline 2D GLS significantly correlated with follow-up 3D volumes among both reverse and adverse remodeling groups. Female gender and higher absolute GLS change upon follow-up were significantly associated with reverse remodeling. ROC-derived cutoff for adverse remodeling reallocated a substantial number of patients from the minimal change group to the adverse remodeling. Following acute STEMI, two-dimensional GLS was associated with and potentially predictive of changes in LV volumes as detected by three-dimensional echocardiography.


Assuntos
Infarto Miocárdico de Parede Anterior , Ecocardiografia Tridimensional , Infarto do Miocárdio , Infarto do Miocárdio com Supradesnível do Segmento ST , Humanos , Feminino , Infarto do Miocárdio com Supradesnível do Segmento ST/complicações , Valor Preditivo dos Testes , Ecocardiografia Tridimensional/métodos , Ecocardiografia/métodos , Infarto Miocárdico de Parede Anterior/complicações , Função Ventricular Esquerda
20.
Int J Pharm ; 639: 122966, 2023 May 25.
Artigo em Inglês | MEDLINE | ID: mdl-37084835

RESUMO

Valsartan (VST) is a poorly soluble antihypertensive drug characterized by its limited dissolution rate and low bioavailability. This study aims to improve VST solubility and dissolution rate via developing liquisolid tablets (LSTs) containing a self-nanoemulsifying drug delivery system (SNEDDS), which is expected to enhance VST bioavailability. This aim was achieved via two designs of experiment. The first was the simplex-lattice design to optimize VST-loaded-SNEDDS using sesame oil, Tween 80, and polyethylene glycol 400. The second was the 32-3-level factorial design to optimize the liquisolid system using the SNEDDS-loaded VST and Neusilin®US2 as a carrier and fumed silica as a coating material. Different excipient ratios (X1) and varioussuper-disintegrants (X2) were also used in developing the optimized VST-LSTs. Thein vitrodissolution of VST from LSTs was compared with the marketed product (Diovan®). Non-compartmental analysis of plasma data after extravascular input with the linear trapezoidal method was used to calculate thepharmacokinetic parameters of the optimized VST-LSTs compared with the marketed tablet in male Wistar rats. The optimized SNEDDS compromised 24.9% sesame oil, 33.3% surfactant, and 41.8% cosurfactant, giving 173.9 nm size and 63.9 mg/ml loading capacity. Also, the SNEDDS-loaded VST tablet revealed good quality attributes with the release of 75% of its content in 5 min and 100% within 15 min. On the other hand, the marketed product took 1 h for the entire drug to be released.Moreover, the maximum plasma concentration (Cmax) of the optimizedVST-LSTwas6585.33 ng/ml within 1 h (Tmax), compared to 2884.67 ng/ml within 2 h of the marketed tablet.The relative bioavailability of the SNEDDS-loaded VST tablet was 213.7% compared to that of the marketed tablet, indicating that this formulation approach could be applied for increasing solubility, dissolution behavior in GIT, and bioavailability of poorly water-soluble drugs.


Assuntos
Nanopartículas , Óleo de Gergelim , Ratos , Animais , Masculino , Valsartana , Disponibilidade Biológica , Ratos Wistar , Emulsões , Sistemas de Liberação de Medicamentos/métodos , Excipientes , Solubilidade , Comprimidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA