Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Molecules ; 28(15)2023 Jul 30.
Artigo em Inglês | MEDLINE | ID: mdl-37570725

RESUMO

Exhaled breath analysis using an e-nose is a groundbreaking tool for exhaled volatile organic compound (VOC) analysis, which has already shown its applicability in several respiratory and systemic diseases. It is still unclear whether food intake can be considered a confounder when analyzing the VOC-profile. We aimed to assess whether an e-nose can discriminate exhaled breath before and after predefined food intake at different time periods. We enrolled 28 healthy non-smoking adults and collected their exhaled breath as follows: (a) before food intake, (b) within 5 min after food consumption, (c) within 1 h after eating, and (d) within 2 h after eating. Exhaled breath was collected by a formerly validated method and analyzed by an e-nose (Cyranose 320). By principal component analysis, significant variations in the exhaled VOC-profile were shown for principal component 1 (capturing 63.4% of total variance) when comparing baseline vs. 5 min and vs. 1 h after food intake (both p < 0.05). No significance was shown in the comparison between baseline and 2 h after food intake. Therefore, the exhaled VOC-profile seems to be influenced by very recent food intake. Interestingly, two hours might be sufficient to avoid food induced alterations of exhaled VOC-spectrum when sampling for research protocols.

2.
J Breath Res ; 18(3)2024 Jun 26.
Artigo em Inglês | MEDLINE | ID: mdl-38876093

RESUMO

Analyzing exhaled volatile organic compounds (VOCs) with an electronic nose (e-nose) is emerging in medical diagnostics as a non-invasive, quick, and sensitive method for disease detection and monitoring. This study investigates if activities like spirometry or physical exercise affect exhaled VOCs measurements in asthmatics and healthy individuals, a crucial step for e-nose technology's validation for clinical use. The study analyzed exhaled VOCs using an e-nose in 27 healthy individuals and 27 patients with stable asthma, before and after performing spirometry and climbing five flights of stairs. Breath samples were collected using a validated technique and analyzed with a Cyranose 320 e-nose. In healthy controls, the exhaled VOCs spectrum remained unchanged after both lung function test and exercise. In asthmatics, principal component analysis and subsequent discriminant analysis revealed significant differences post-spirometry (vs. baseline 66.7% cross validated accuracy [CVA],p< 0.05) and exercise (vs. baseline 70.4% CVA,p< 0.05). E-nose measurements in healthy individuals are consistent, unaffected by spirometry or physical exercise. However, in asthma patients, significant changes in exhaled VOCs were detected post-activities, indicating airway responses likely due to constriction or inflammation, underscoring the e-nose's potential for respiratory condition diagnosis and monitoring.


Assuntos
Asma , Testes Respiratórios , Nariz Eletrônico , Exercício Físico , Expiração , Espirometria , Compostos Orgânicos Voláteis , Humanos , Compostos Orgânicos Voláteis/análise , Masculino , Feminino , Testes Respiratórios/métodos , Testes Respiratórios/instrumentação , Asma/diagnóstico , Asma/fisiopatologia , Asma/metabolismo , Adulto , Pessoa de Meia-Idade , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA