1.
BMC Res Notes ; 2: 77, 2009 May 06.
Artigo em Inglês | MEDLINE | ID: mdl-19419551

RESUMO

BACKGROUND: The aim of this study was to develop a simple organ score derived from the Critical Care Minimum Data Set (CCMDS) to compare with the Sequential Organ Failure Assessment (SOFA) score, a previously validated score of organ dysfunction. FINDINGS: The CCMDS collects data regarding the support of seven organ systems. To create a CCMDS derived score each level of organ support was allocated a numerical value. SOFA scores were collected retrospectively from each patient in the study. Data was collected in 50 sequential admissions over the first 5 days of their admission. This generated a total of 147 pairs of data for comparison.Scatter plots and Spearman's rank correlation coefficient suggest a weak positive association between our CCMDS-derived score and the SOFA score. Daily Bland-Altman plots reveal minimal bias between the score but wide limits of agreement. CONCLUSION: Our CCMDS-derived score cannot be regarded as an indicator of severity of organ dysfunction and cannot replace SOFA scores when a daily marker of organ dysfunction is required.

SELEÇÃO DE REFERÊNCIAS