Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Br J Radiol ; 88(1045): 20140658, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25486387

RESUMO

OBJECTIVE: To estimate effective dose of cone beam CT (CBCT) of the facial skeleton with focus on measurement methods and scanning protocols. METHODS: A systematic review, which adhered to the preferred reporting items for systematic reviews (PRISMA) Statement, of the literature up to April 2014 was conducted. Data sources included MEDLINE®, The Cochrane Library and Web of Science. A model was developed to underpin data extraction from 38 included studies. RESULTS: Technical specifications of the CBCT units were insufficiently described. Heterogeneity in measurement methods and scanning protocols between studies made comparisons of effective doses of different CBCT units and scanning protocols difficult. Few studies related doses to image quality. Reported effective dose varied across studies, ranging between 9.7 and 197.0 µSv for field of views (FOVs) with height ≤5 cm, between 3.9 and 674.0 µSv for FOVs of heights 5.1-10.0 cm and between 8.8 and 1073.0 µSv for FOVs >10 cm. There was an inconsistency regarding reported effective dose of studies of the same CBCT unit with the same FOV dimensions. CONCLUSION: The review reveals a need for studies on radiation dosages related to image quality. Reporting quality of future studies has to be improved to facilitate comparison of effective doses obtained from examinations with different CBCT units and scanning protocols. A model with minimum data set on important parameters based on this observation is proposed. ADVANCES IN KNOWLEDGE: Data important when estimating effective dose were insufficiently reported in most studies. A model with minimum data based on this observation is proposed. Few studies related effective dose to image quality.


Assuntos
Tomografia Computadorizada de Feixe Cônico/normas , Ossos Faciais/diagnóstico por imagem , Imagens de Fantasmas , Humanos , Doses de Radiação
2.
Dentomaxillofac Radiol ; 42(7): 20120343, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23610090

RESUMO

OBJECTIVES: To demonstrate the feasibility of GafChromic(®) XR-QA2 (ISP Corp., Wayne, NJ) as a dosemeter when performing measurements of the effective dose from three cone beam CT (CBCT) units and to compare the doses from examinations of three common dental clinical situations. A second aim was to compare the radiation doses for three digital panoramic units with the doses for the CBCT units. METHODS: The CBCT units used were Veraviewepocs 3De(®) (J Morita MFG Corp., Kyoto, Japan), ProMax(®) 3D (Planmeca, Helsinki, Finland) and NewTom VGi(®) (Quantitative Radiology, Verona, Italy). GafChromic XR-QA2 films were placed between the selected layers of the head and neck of a tissue-equivalent human skull (RANDO(®) phantom; The Phantom Laboratory, Salem, NY). The exposure parameters were set using the automatic exposure control function of the units. Depending on the availability, medium and smaller field of view (FOV) scanning modes were used. The effective dose was estimated using the 2007 International Commission on Radiological Protection formalism. RESULTS: The lowest effective dose of a CBCT unit was observed for ProMax 3D, FOV 4 × 5 cm (10 µSv), the highest for NewTom VGi, FOV 8 × 8 cm-high resolution (129 µSv). The range of effective doses for digital panoramic machines measured was 8-14 µSv. CONCLUSIONS: This study demonstrates the feasibility of using radiochromic films for dental CBCT and panoramic dosimetry.


Assuntos
Tomografia Computadorizada de Feixe Cônico/métodos , Doses de Radiação , Radiografia Dentária Digital/métodos , Radiografia Panorâmica/métodos , Filme para Raios X/classificação , Encéfalo/efeitos da radiação , Calibragem , Vértebras Cervicais/efeitos da radiação , Tomografia Computadorizada de Feixe Cônico/instrumentação , Dente Canino/diagnóstico por imagem , Relação Dose-Resposta à Radiação , Estudos de Viabilidade , Humanos , Mandíbula/diagnóstico por imagem , Mandíbula/efeitos da radiação , Maxila/diagnóstico por imagem , Dente Molar/diagnóstico por imagem , Mucosa Bucal/efeitos da radiação , Glândula Parótida/efeitos da radiação , Imagens de Fantasmas , Radiografia Dentária Digital/instrumentação , Radiografia Panorâmica/instrumentação , Radiometria/instrumentação , Eficiência Biológica Relativa , Pele/efeitos da radiação , Articulação Temporomandibular/diagnóstico por imagem , Dosimetria Termoluminescente/instrumentação , Glândula Tireoide/efeitos da radiação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA