Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 47
Filtrar
1.
Am J Otolaryngol ; 45(4): 104310, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38677148

RESUMO

PURPOSE: Chronic rhinosinusitis with nasal polyps (CRSwNP) often alters sleep quality. Dupilumab emerged as an innovative and effective therapy for refractory/recurrent severe CRSwNP. The aim of this observational retrospective study was to evaluate the sleep quality in patients with CRSwNP who underwent treatment with dupilumab. MATERIALS AND METHODS: Forty-five patients treated with dupilumab for CRSwNP were enrolled. Clinical parameters (age, sex, comorbidities, Nasal Polyp Score - NPS, Asthma Control Test - ACT), nasal cytology, quality of life (Sino Nasal Outcome Test 22 - SNOT-22), sleep quality (Pittsburgh Sleep Quality Index - PSQI, Epworth Sleepiness Scale - ESS), and risk of sleep apnea (STOP-BANG) were recorded before treatment (T0), and after 3 (T1), 6 (T2), and 12 months (T3). RESULTS: NPS, ACT and SNOT-22 total score improved during treatment (p < 0.05). Meanwhile, all sleep parameters evaluated with SNOT-22, ESS and PSQI improved over time (p < 0.001), expect for PSQI Use of sleeping medications. Indeed, sleep drugs are rarely used before and during the treatment. The global sleep quality was classified as poor in 88.9 % of cases at T0 and decreased to 5.7 % at T3. A high risk of sleep apnea was revealed by the STOP-BANG in 68.9 % of cases at T0 and 2.8 % of patient at T3 (p < 0.001). CONCLUSIONS: Dupilumab improves the sleep quality and reduce the risk of sleep apnea in patients with severe CRSwNP. Its favorable effect occurs within 3 months and is maintained during the treatment.


Assuntos
Anticorpos Monoclonais Humanizados , Pólipos Nasais , Rinite , Sinusite , Qualidade do Sono , Humanos , Pólipos Nasais/complicações , Pólipos Nasais/tratamento farmacológico , Masculino , Sinusite/tratamento farmacológico , Sinusite/complicações , Feminino , Rinite/tratamento farmacológico , Rinite/complicações , Doença Crônica , Anticorpos Monoclonais Humanizados/uso terapêutico , Pessoa de Meia-Idade , Estudos Retrospectivos , Adulto , Resultado do Tratamento , Qualidade de Vida , Idoso , Rinossinusite
2.
Eur Arch Otorhinolaryngol ; 281(7): 3361-3369, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38329527

RESUMO

PURPOSE: Sinonasal nuclear protein in testis carcinoma (SNUTC) is a rare, aggressive malignancy caused by genetic rearrangements in the NUTM1 gene. The prognosis of SNUTC ranks among the most unfavorable within the naso-sinusal district, with an overall survival of 9.7 months. This systematic review aimed to determine the best therapeutic strategy for SNUTC. METHODS: We reviewed eligible articles for patient demographics, TNM and stage at presentation, best response after primary treatment, disease-free survival and overall survival (OS) times, other following therapy lines, and final outcomes. RESULTS: Among 472 unique citations, 17 studies were considered eligible, with reported treatment data for 25 patients. Most studies (n = 12) were case reports. The most frequently administered treatment regimen was surgery as primary treatment and combined radiochemotherapy as second-line or adjuvant treatment. Four patients were alive at follow-up. CONCLUSION: Basing on the existing literature, a standardized line in the treatment of SNUTC is not yet well delineated. A self-personalized strategy of therapy should be drawn on each patient affected by SNUTC.


Assuntos
Proteínas Nucleares , Humanos , Carcinoma/terapia , Carcinoma/genética , Carcinoma/patologia , Terapia Combinada , Proteínas de Neoplasias/genética , Estadiamento de Neoplasias , Proteínas Nucleares/genética , Proteínas Oncogênicas/genética , Neoplasias dos Seios Paranasais/terapia , Neoplasias dos Seios Paranasais/genética , Neoplasias dos Seios Paranasais/patologia
3.
Audiol Neurootol ; 28(1): 52-62, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36195076

RESUMO

INTRODUCTION: Hearing loss is known to play a fundamental role in voice production due to a lack of auditory feedback. In this study, we evaluated both fundamental frequency (F0) and loudness of voice on adult deaf patients subjected to cochlear implantation, and we analyzed these results according to the prelingual or postlingual onset of the deafness. METHODS: The study population, balanced in terms of sex, consisted of 32 adults who had undergone cochlear implantation due to severe or profound bilateral hearing loss (16 with prelingual deafness and 16 with postlingual deafness) and their outcomes were compared with a control group of 32 normal hearing (NH) subjects. All subjects were asked to utter the sustained vowel /a/ for at least 5 s and then to read an Italian phonetically balanced text. Voice recordings were performed by means of an ambulatory phonation monitoring (APM 3200). Measurements were performed without cochlear implant (CI), then with CI switched on, both in quiet condition and with background noise. RESULTS: Compared to NH subjects, deaf individuals were overall characterized by higher F0 and loudness values, especially in the vowel task than the reading. In the sustained vowel task, no patients demonstrated significant voice changes after switching on the CI; contrarily, in the reading task, the use of the CI reduced both loudness and F0 up to values comparable to NH subjects, although only in males. There was no significant difference in speech parameters between prelingual and postlingual deafness, although overall lower values were evident in case of postlingual deafness. The use of the CI showed a significant reduction of F0 in males with postlingual deafness and of loudness, both for patients with prelingual and postlingual deafness. Finally, there was a positive correlation between postoperative hearing thresholds and overall speech loudness, highlighting how subjects with better hearing outcomes after CI positioning generally speak with a lower loudness and therefore a reduced vocal effort and load. DISCUSSION/CONCLUSION: We found similar speech performances between prelingual and postlingual deafness, both in the vowel /a/ phonation and in the reading, providing a further suggestion that prelingual adult patients may benefit from cochlear implantation in phonation as well, in addition to the known excellent hearing outcomes. Overall, these results highlight the ability of the CI to adjust in everyday speech certain phonatory aspects such as F0 and loudness by restoring the auditory feedback.


Assuntos
Implante Coclear , Implantes Cocleares , Surdez , Percepção da Fala , Adulto , Masculino , Humanos , Fonação , Surdez/cirurgia , Surdez/reabilitação , Audição
4.
Audiol Neurootol ; 28(4): 246-254, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36750032

RESUMO

INTRODUCTION: The study aimed to investigate binaural cues in the rehabilitation of unilateral occluded ears with a bone conduction hearing aid. METHODS: The study sample consisted of 40 adult volunteers with normal hearing. Unilateral pseudo-conductive hearing loss was induced by inserting an earplug into the external auditory canal (EAC) and silicone material in the concha for ear impression. The adaptive speech-in-noise test (Italian Matrix test) was performed in three spatial orientations to assess binaural cues (summation, squelch, and head shadow effects). All evaluations were performed in the normal condition, after EAC occlusion, and after application of an adhesive bone conduction hearing aid. Binaural contrast differences were calculated in the three conditions. RESULTS: In the EAC occlusion condition, there was a significant increase in the signal-to-noise ratio (SNR) in both the S0N0 (2.4 dB) and the S90N-90 (7.7 dB) settings, and a slight albeit significant increase in the S0N90 setting (1.35 dB). After fitting the BC hearing aid, there was a reduction of -1.8 dB SNR (p < 0.001) in the S0N0 setting and -2 dB (p = 0.003) in the S90N-90 setting. There was no improvement in the SNR (p = 0.405) in evaluation of the squelch effect (S0N90). These data were corroborated by a better binaural contrast due to a reduction in the summation effect in the monaural occlusion condition and a subsequent reduction in binaural contrast after fitting the hearing aid due to an increase in the summation effect (-2.5 dB vs. 0.3 dB; p < 0.001). CONCLUSIONS: Application of a bone conduction hearing aid in unilateral pseudo-conductive hearing loss strengthens speech recognition of noise by improving the summation effect and impeding the shadow effect of the head; however, there appears to be no improvement in speech perception in noise due to spatial release from masking.


Assuntos
Implante Coclear , Auxiliares de Audição , Percepção da Fala , Adulto , Humanos , Condução Óssea , Perda Auditiva Condutiva , Audição
5.
Folia Phoniatr Logop ; 2023 Nov 30.
Artigo em Inglês | MEDLINE | ID: mdl-38035546

RESUMO

Introduction Hearing loss (HL) strongly impacts communication abilities and impairs social interactions. Moreover, it modifies the vocal parameters of affected patients. The effects of hearing rehabilitation through hearing aids (HA) on the vocal production of patients suffering from HL have not been thoroughly analyzed in literature. The aim of this study is to use the Ambulatory Phonation Monitor (APM), a portable vocal dosimeter, to evaluate the variations in the vocal production of a group of patients suffering from moderate-to-severe HL treated with HA, and the relationship between such modifications and quality of life (QoL). Materials and Methods Twenty-six patients suffering from a variable degree of HL and treated with HA have been enrolled. Each of them underwent an evaluation before and 4 months after rehabilitation with HA. The analysis of daily voice production was carried out with the APM, while subjective QoL data were collected through the Speech, Spatial, and Qualities questionnaire (SSQ) and the International Outcome Inventory for Hearing Aids (IOI-HA). The differences in phonatory measurements and subjective evaluations before and after HA rehabilitation were assessed using Wilcoxon signed rank test. The Spearman correlation test was used to analyze the correlation between phonatory measurements, auditory measurements and SSQ scores. Results Significant differences in the APM parameters before and after HA rehabilitation were found. After 4 months of HA use, we recorded a significant increase in phonation time and percentage of phonation time, and a significant decrease in average amplitude in dB SPL. We also found a significant increase in the SSQ scores after HA rehabilitation. Finally, we were able to detect low but significant correlations between phonatory measurements and SSQ results. Conclusions The APM proved to be a useful instrument in the evaluation of the benefits of HA and its measurements can be used as indicators of the participation in communication and social life of patients with HL, which are strongly related to QoL.

6.
Am J Otolaryngol ; 43(2): 103325, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34933163

RESUMO

PURPOSE: Recurrence of chronic rhinosinusitis with nasal polyps (CRSwNP) is highly variable, reaching 55-60% of cases. Different results about clinical parameters as recurrence predictors has been reported. The aim of this retrospective study was to evaluate CRSwNP recurrence risk after a long-term follow-up (up to 20 years). Moreover, the role of nasal cytology was assessed. MATERIALS AND METHODS: Sixty-one patients who underwent functional endoscopic sinus surgery for CRSwNP were enrolled. Clinical parameters were recorded. Nasal cytology was performed at follow-up examinations. The Kaplan-Meier method was used to obtain the recurrence-free survival curves. The median number of recurrences per year was evaluated. RESULTS: Five- and 10-year recurrence rates were 30.29% and 66.06%, respectively. Median recurrence-free survival was 106 months. Asthma and Aspirin-Exacerbated Respiratory Disease represented predictors of multiple recurrences (p < 0.05). Intranasal steroids were the main treatment to prevent relapses (p < 0.05). Patients with normal cytology at follow-up evaluation had a lower probability to have first recurrence within 10 years (59% of cases), compared to neutrophil or eosinophil infiltrate (100% and 88% of cases, respectively) (p < 0.05). CONCLUSIONS: CRSwNP has a high recurrence risk, also more than 10 years after surgery. Nasal cytology may identify subjects with a higher risk of early recurrence.


Assuntos
Pólipos Nasais , Rinite , Sinusite , Doença Crônica , Humanos , Pólipos Nasais/cirurgia , Recidiva , Estudos Retrospectivos , Rinite/cirurgia , Sinusite/cirurgia
7.
Audiol Neurootol ; 26(5): 353-360, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33849007

RESUMO

BACKGROUND AND AIM: Amyotrophic lateral sclerosis (ALS) is a neuromuscular progressive disorder, characterized by limb and bulbar muscle wasting and weakness. 30% of patients present a bulbar onset, while 70% a spinal outbreak, although most of them develop bulbar impairment later on. Due to the lack of an early biomarker of bulbar involvement, we chose to evaluate the role of stapedial reflex (SR) in order to predict preclinical bulbar impairment in ALS. MATERIALS AND METHODS: We enrolled 36 ALS patients. We assessed revised-ALS functional-rating-scale and SR for a total of 4 visits. We established the presence of SR, acoustic reflex latency test (ARLT), and SRs Decay. Patients who had not develop bulbar signs at fourth visit continued follow-up up to 15 months. Data were analyzed by using Mann-Whitney U test, Friedman test, and Cox regression analysis. RESULTS: We observed that SRs Decay at 500 and 1,000 Hz is the first parameter of SR to get altered in all ALS patients before the development of bulbar impairment. Twenty-eight patients developed bulbar impairment during the study. We highlighted a correlation between the progression rate of disease and both time of SRs Decay alteration and time of bulbar impairment from disease onset. Four patients who did not develop bulbar impairment had a progression rate lower than the other ones (p < 0.05). DISCUSSION AND CONCLUSIONS: This study shows that SR Decay test could be a sensitive measure for detecting pre-symptomatic bulbar involvement in ALS and could represent a simple, noninvasive, and useful biomarker of disease progression.


Assuntos
Esclerose Lateral Amiotrófica , Biomarcadores , Humanos , Reflexo Acústico
8.
Med Sci Monit ; 27: e930232, 2021 May 18.
Artigo em Inglês | MEDLINE | ID: mdl-34001843

RESUMO

BACKGROUND Indications for cochlear implantation (CI) are constantly being updated, and with them, the audiometric results achieved by patients. Patient satisfaction should always be considered, even in patients with lower audiological results. The aim of the present study was to compare quality of life (QoL), self-perceived hearing benefit, and audiometric results between prelingually and postlingually deafened patients, with and without sound deprivation, after CI. MATERIAL AND METHODS The sample included 46 patients with bilateral sensorineural hearing loss: 22 postlingually deafened and 24 prelingually deafened, further subdivided into sound-deprived (n=10) and non-sound-deprived (n=14). Auditory performance was evaluated with pure tone audiometry, speech recognition scores (SRS), and self-perceived hearing benefit, whereas QoL was evaluated with 2 self-reported questionnaires (Comprehensive Cochlear Implant Questionnaire and World Health Organization Quality of Life-BREF). RESULTS Audiometric results were worse in the prelingually deafened than in the postlingually deafened group, and worse in the prelingually deafened patients with sound deprivation. There was no marked difference in perceived CI benefit or QoL between the 2 groups or within the 2 prelingually deafened subgroups. No correlation was found between SRS and duration of CI use or between QoL and SRS in the prelingually and postlingually deafened groups. CONCLUSIONS Our findings demonstrate better auditory performance for the postlingually deafened group and no differences in perceived QoL or benefit of CI between the groups. The sound-deprived patients had equal scores on the perceived QoL questionnaire. These analyses suggest that sound-deprived, prelingually deafened patients may benefit from CI.


Assuntos
Implante Coclear/estatística & dados numéricos , Implantes Cocleares/estatística & dados numéricos , Surdez/cirurgia , Adulto , Audiometria de Tons Puros/estatística & dados numéricos , Feminino , Audição/fisiologia , Perda Auditiva Neurossensorial/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Qualidade de Vida , Estudos Retrospectivos , Som , Testes de Discriminação da Fala/métodos , Inquéritos e Questionários , Adulto Jovem
9.
Int Tinnitus J ; 24(1): 21-25, 2020 Nov 18.
Artigo em Inglês | MEDLINE | ID: mdl-33206494

RESUMO

Acoustic Neuromas (AN) are benign tumors of the vestibulocochlear nerve with symptomatology that includes unilateral sensorineural hearing loss, tinnitus, dizziness, facial and/or trigeminal neuropathy. There are different treatment options of AN: watchful waiting, microsurgical resection, stereotactic radiation and the choice depends by many variables such age, health and hearing of patients as size, location and growing status of tumor. The objective of this retrospective study is to better understand the differences in demographic, hearing status, symptoms, tumor characteristics in patients affected by AN presenting at our clinic and analyze the factors that influence the therapeutic choice. One-hundred three patients affected by AN were included in the study. All subjects underwent a detailed clinical interview and audio-vestibular examination, and Magnetic Resonance Imaging (MRI). Tumor status, growing or stable was estimated comparing new size to any previous MRI with at least a 6-month interval. Descriptive statistics were used for clinical and demographic features of patients. Therapeutic choices related to subjective symptoms were assessed with the chi-square test. Treatment options in our sample included watchful waiting, surgical resection and stereotactic radiosurgery. Overall, 17 patients (16.5%) pursued surgical resection via the retrosigmoid approach, 3 patients (2.9%) were treated with gamma knife stereotactic radiosurgery and 83 patients (80.6%) underwent watchful waiting. The decision-making process for AN treatment was based on size of tumor, age, and hearing loss; a statistically significant difference was found at Z test about size of tumor and PTA of patients that underwent retrosigmoid surgery. No statistically significant difference was found at chi-square test between the type of treatment and symptoms (p=0.719). The analysis of the data showed that the main elements taken into consideration for surgery were the size of tumor (p<0.000004) and, secondly, the PTA threshold; the latter may be due to the fact that patients with bigger tumors had greater hearing impairment (p<0.001). Disease progression influenced the therapeutic decision making with a positive correlation between tumor progression and surgery (p<0.001). In our sample, active surveillance was the most adopted option for small tumor, slow growth and old age. Microsurgical resection was the preferred treatment in patients with large tumors, hearing deterioration and rapid growth. Stereotactic radiation has been proposed in a few cases of elderly patients with slow growing tumor and mild hearing loss.


Assuntos
Tomada de Decisão Clínica , Neuroma Acústico/terapia , Adulto , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Feminino , Perda Auditiva/diagnóstico , Perda Auditiva/etiologia , Humanos , Masculino , Microcirurgia/métodos , Pessoa de Meia-Idade , Neuroma Acústico/diagnóstico , Neuroma Acústico/radioterapia , Neuroma Acústico/cirurgia , Radiocirurgia , Estudos Retrospectivos , Índice de Gravidade de Doença , Conduta Expectante
10.
Eur Arch Otorhinolaryngol ; 276(8): 2165-2170, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31053966

RESUMO

PURPOSE: We compared our historical medium-term data obtained with an active semi-implanted bone conduction device and the hearing results of a new passive bone conduction hearing device to determine its predictive value for the hearing results with the semi-implanted device. METHODS: The study sample was 15 patients with an active bone conduction implant (mean follow-up 26 months). Pure tone audiometry was performed with headphones, sound field speech audiometry was conducted unaided, and free-field speech audiometry was carried out with both the active bone conduction system and the passive device switched off. RESULTS: As compared with the unaided condition, speech reception was significantly improved with both devices. Comparison of speech reception threshold at 100% of word recognition showed no difference between the active and the passive device. At lower intensity the difference in speech perception was significant in the patients with monaural fitting (group A) and was non-statistically significant in those with binaural fitting (group B); the speech reception threshold at 50% of word recognition was 26.00 dB (± 10.22) with the active implant and 30.50 dB (± 7.98) with the passive device in group A (p = 0.047) and 24.00 dB (± 5.48) and 29.00 dB (± 2.24) in group B (p = 0.052), respectively. CONCLUSIONS: The hearing outcome after active bone conduction implant was comparable to published data. Compared with the unaided condition, speech recognition was significantly improved with the passive device. The device may also provide value to predict the hearing outcome with the implanted device, especially at higher intensities. LEVEL OF EVIDENCE: IV.


Assuntos
Condução Óssea , Auxiliares de Audição , Perda Auditiva Condutiva , Implantação de Prótese/métodos , Qualidade de Vida , Adulto , Audiometria da Fala/métodos , Feminino , Auxiliares de Audição/classificação , Auxiliares de Audição/tendências , Perda Auditiva Condutiva/diagnóstico , Perda Auditiva Condutiva/psicologia , Perda Auditiva Condutiva/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Avaliação de Resultados em Cuidados de Saúde , Desenho de Prótese , Percepção da Fala
11.
Eur Arch Otorhinolaryngol ; 274(2): 679-683, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27577043

RESUMO

The aim of the study is to investigate acoustic reflex testing in amyotrophic lateral sclerosis patients. Amplitude, latency, and rise time of stapedial reflex were recorded for 500 and 1000 Hz contralateral stimulus. Statistical analysis was performed by the Wilcoxon test and the level of significance was set at 5 %. Fifty-one amyotrophic lateral sclerosis patients and ten sex- and age-matched control subjects were studied. Patients were further divided in two groups: amyotrophic lateral sclerosis-bulbar (38 cases, with bulbar signs at evaluation) and amyotrophic lateral sclerosis-spinal (13 cases, without bulbar signs at evaluation). Stapedial reflex was present in all patients. There was a statistically significant difference in the mean amplitude, latency, and rise time between the amyotrophic lateral sclerosis patients as compared with the controls. Amplitude was lower in both the amyotrophic lateral sclerosis-bulbar and the amyotrophic lateral sclerosis-spinal patients than in the controls (p < 0.05) and rise time was longer in both patient groups compared with the controls (p < 0.05). These results confirm the presence of abnormal acoustic reflex patterns in amyotrophic lateral sclerosis cases with bulbar signs and, moreover, suggesting a possible subclinical involvement of the stapedial motor neuron even in amyotrophic lateral sclerosis-spinal patients. Amplitude and rise time seem to be good sensitive parameters for investigating subclinical bulbar involvement.


Assuntos
Esclerose Lateral Amiotrófica/fisiopatologia , Reflexo Acústico , Adulto , Idoso , Estudos de Casos e Controles , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estapédio/fisiopatologia
12.
Int Tinnitus J ; 21(2): 98-103, 2017 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-29336126

RESUMO

OBJECTIVE: The purpose of this study was to evaluate the effect of tobacco use on the Eustachian tube and inner ear function. STUDY DESIGN: Case-control study. SUBJECTS AND SETTINGS: Thirty-one nonsmoking volunteers and 34 smoking subjects recruited in an University Hospital, submitted to an audiological evaluation including pure tone audiometry, basal tympanogram, stapedial reflexes analysis, and nine-step eustachian tube (ET) function test. RESULTS: Pure Tone Average (PTA) threshold at all frequencies tested was 12.5 dB in smokers and 3.7 in nonsmoking subjects. Nine smokers (27%) presented some degree of hearing loss versus none in the nonsmoker group. Linear regression analysis showed a higher degree of sensorineural hearing loss with age in smokers. Among the smokers, 20 subjects (59%) presented an impaired tubal function for the nine-step inflation/deflation tympanometric test, while only 6 (19%) subjects in the group of nonsmokers showed a tubal dysfunction. CONCLUSION: Tobacco use may reduce the ability to hear, mainly causing a sensorineural hearing loss for higher frequencies. We also found the presence of a high number of smokers suffering from tubal dysfunction. This has an important clinical relevance, not only because smoking increases the incidence of middle ear diseases, but also because tubal dysfunction may cause nonspecific symptoms characterised by ear fullness and difficulties in middle ear equalisation.


Assuntos
Tuba Auditiva/fisiopatologia , Perda Auditiva/etiologia , Audição/fisiologia , Fumar/efeitos adversos , Testes de Impedância Acústica , Adulto , Idoso , Audiometria de Tons Puros , Estudos de Casos e Controles , Feminino , Perda Auditiva/epidemiologia , Perda Auditiva/fisiopatologia , Humanos , Incidência , Itália/epidemiologia , Masculino , Pessoa de Meia-Idade , Fatores de Risco , Fumar/epidemiologia , Adulto Jovem
13.
Eur Arch Otorhinolaryngol ; 273(1): 51-6, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25552243

RESUMO

Hearing loss in Menière's disease has been described to affect above all low frequencies (upward curve) with a tendency to become irreversible and non-fluctuating at the higher frequencies (peaked curve) over time. The aim of the study was to determine the effects of MD on hearing function on the basis of differences existing between the affected and the unaffected ear in a group of patients affected by definite unilateral MD and whose contralateral ear was not affected by any disease other than age-related hearing loss (ARHL). Following this procedure we have also evaluated the possible effects of age and disease duration on hearing loss in MD. The study group consisted of 86 subjects affected by definite unilateral MD. In our sample a peaked audiometric curve characterized the affected ears; however, the result after subtracting the normal ear hearing threshold was an upward sloping curve, which highlighted the greater suffering at the lower frequencies. On the basis of differences existing between affected and unaffected ear, our data suggest that threshold evolution is more related to disease duration rather than to age.


Assuntos
Limiar Auditivo/fisiologia , Doença de Meniere/fisiopatologia , Adolescente , Adulto , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Audiometria de Tons Puros , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Adulto Jovem
14.
Anim Genet ; 45(1): 1-11, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23889699

RESUMO

Selection is the major force affecting local levels of genetic variation in species. The availability of dense marker maps offers new opportunities for a detailed understanding of genetic diversity distribution across the animal genome. Over the last 50 years, cattle breeds have been subjected to intense artificial selection. Consequently, regions controlling traits of economic importance are expected to exhibit selection signatures. The fixation index (Fst ) is an estimate of population differentiation, based on genetic polymorphism data, and it is calculated using the relationship between inbreeding and heterozygosity. In the present study, locally weighted scatterplot smoothing (LOWESS) regression and a control chart approach were used to investigate selection signatures in two cattle breeds with different production aptitudes (dairy and beef). Fst was calculated for 42 514 SNP marker loci distributed across the genome in 749 Italian Brown and 364 Piedmontese bulls. The statistical significance of Fst values was assessed using a control chart. The LOWESS technique was efficient in removing noise from the raw data and was able to highlight selection signatures in chromosomes known to harbour genes affecting dairy and beef traits. Examples include the peaks detected for BTA2 in the region where the myostatin gene is located and for BTA6 in the region harbouring the ABCG2 locus. Moreover, several loci not previously reported in cattle studies were detected.


Assuntos
Cruzamento , Bovinos/genética , Genética Populacional/métodos , Seleção Genética , Animais , Frequência do Gene , Heterozigoto , Itália , Masculino , Fenótipo , Polimorfismo de Nucleotídeo Único
15.
Acta Otorhinolaryngol Ital ; 44(3): 192-197, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38712517

RESUMO

Objective: Olfactory dysfunction (OD) represents a frequent complaint in general population and especially in patients with chronic sinonasal diseases. The aim of this study was the cross-cultural adaptation and validation of the Self-reported Mini Olfactory Questionnaire (Self-MOQ) into Italian. Methods: One hundred fifty patients affected by chronic sinonasal diseases and reporting hyposmia were enrolled. Other 150 normosmic subjects without inflammatory or neoplastic sinonasal disorders were used as a control group. The Short-form 36 (SF-36) questionnaire was used for clinical validity. Results: Cronbach's alpha coefficient was 0.825. The test-retest reliability was excellent. The good correlation between the Self-MOQ and the Visual Analogue Scale scores (p < 0.05) demonstrated the construct validity of the questionnaire. The Self-MOQ was able to distinguish between subjects with or without OD (p < 0.05). Higher Self-MOQ score was found in case of nasal obstruction and posterior rhinorrhoea (p < 0.05). Self-MOQ showed significant correlation with SF-36 general health, SF-36 role functioning/physical, and SF-36 pain (p < 0.05). Conclusions: The Italian version of the Self-MOQ showed good internal consistency, test-retest reliability, construct, and clinical validity.


Assuntos
Transtornos do Olfato , Autorrelato , Humanos , Feminino , Masculino , Itália , Reprodutibilidade dos Testes , Pessoa de Meia-Idade , Transtornos do Olfato/diagnóstico , Adulto , Idoso , Traduções , Inquéritos e Questionários , Adulto Jovem
16.
Acta Otorhinolaryngol Ital ; 44(2): 113-119, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38651553

RESUMO

Objective: To determine the benefits of binaural hearing rehabilitation in patients with monaural conductive or mixed hearing loss treated with a unilateral bone conduction implant (BCI). Methods: This monocentric study includes 7 patients with monaural conductive or mixed hearing loss who underwent surgical implantation of a unilateral BCI (Bonebridge, Med-El). An ITA Matrix test was performed by each patient included in the study - without and with the BCI and in three different settings - to determine the summation effect, squelch effect and head shadow effect. Subjective hearing benefits were assessed using the Abbreviated Profile of Hearing Aid Benefit (APHAB) questionnaire. Results: The difference in signal to noise ratio of patients without and with BCI was 0.79 dB in the summation setting (p < 0.05), 4.62 dB in the head shadow setting (p < 0.05) and 1.53 dB (p = 0.063) in the squelch setting. The APHAB questionnaire revealed a subjective discomfort in the presence of unexpected sounds in patients using a unilateral BCI (aversiveness score) compared to the same environmental situations without BCI, with a mean discomfort score of 69.00% (SD ± 21.24%) with monaural BCI versus 25.67% (SD ± 16.70%) without BCI (difference: -43.33%, p < 0.05). In terms of global score, patients wearing a unilateral Bonebridge implant did not show any significant differences compared to those without hearing aid (difference: -4.00%, p = 0.310). Conclusions: Our study shows that the use of a unilateral BCI in patients affected by monaural conductive or mixed hearing loss can improve speech perception under noise conditions due to the summation effect and to the decrease of the head shadow effect. However, since monaural BCIs might lead to discomfort under noise conditions in some subjects, a pre-operative assessment of the possible individual benefit of a monaural BCI should be carried out in patients affected by unilateral conductive or mixed hearing loss in order to investigate the possible additional effect of the fitting of hearing aids.


Assuntos
Condução Óssea , Perda Auditiva Condutiva , Perda Auditiva Condutiva-Neurossensorial Mista , Humanos , Feminino , Masculino , Pessoa de Meia-Idade , Perda Auditiva Condutiva-Neurossensorial Mista/reabilitação , Perda Auditiva Condutiva-Neurossensorial Mista/cirurgia , Adulto , Perda Auditiva Condutiva/reabilitação , Perda Auditiva Condutiva/cirurgia , Perda Auditiva Condutiva/fisiopatologia , Auxiliares de Audição , Idoso
17.
Sci Rep ; 14(1): 12787, 2024 06 04.
Artigo em Inglês | MEDLINE | ID: mdl-38834775

RESUMO

Cochlear implant users experience difficulties controlling their vocalizations compared to normal hearing peers. However, less is known about their voice quality. The primary aim of the present study was to determine if cochlear implant users' voice quality would be categorized as dysphonic by the Acoustic Voice Quality Index (AVQI) and smoothed cepstral peak prominence (CPPS). A secondary aim was to determine if vocal quality is further impacted when using bilateral implants compared to using only one implant. The final aim was to determine how residual hearing impacts voice quality. Twenty-seven cochlear implant users participated in the present study and were recorded while sustaining a vowel and while reading a standardized passage. These recordings were analyzed to calculate the AVQI and CPPS. The results indicate that CI users' voice quality was detrimentally affected by using their CI, raising to the level of a dysphonic voice. Specifically, when using their CI, mean AVQI scores were 4.0 and mean CPPS values were 11.4 dB, which indicates dysphonia. There were no significant differences in voice quality when comparing participants with bilateral implants to those with one implant. Finally, for participants with residual hearing, as hearing thresholds worsened, the likelihood of a dysphonic voice decreased.


Assuntos
Implantes Cocleares , Qualidade da Voz , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Adulto , Disfonia/fisiopatologia , Acústica da Fala , Implante Coclear
18.
Metabolites ; 14(2)2024 Jan 25.
Artigo em Inglês | MEDLINE | ID: mdl-38392978

RESUMO

Benign paroxysmal positional vertigo (BPPV) represents the most frequent cause of peripheral vertigo. In most cases, it is successfully treated using the canalith repositioning procedure, but it is often followed by continuous lightheadedness in the absence of vertigo or nystagmus (residual dizziness, RD). Our aim is to describe the clinical effectiveness and the urine metabolomics profile of treating these patients with polyphenol compound supplementation. We enrolled 30 patients reporting RD after BPPV of the posterior semicircular canal (PSC) successfully treated using the Semont maneuver. Supplementation with a polyphenol compound was administered for 60 days, and patients were evaluated after 30 and 60 days of treatment using self-administered questionnaires (Visual Analog Scales for Dizziness and Nausea, Dizziness Handicap Inventory, DHI) and urine metabolomics analysis performed using 1H-NMR spectroscopy and multivariate followed by univariate analysis. Most patients reported excellent or good efficacy in the treatment of RD with a significant decrease in VAS and DHI values. The metabolomics analysis identified six significant metabolites related to the treatment, namely 1-methylnicotinamide, anserine, hippurate, lysine, methyl succinate and urea, indicating the inflammatory activities and antioxidant properties of the polyphenol compound. These preliminary data suggest that supplementation with a polyphenol compound could induce some metabolic changes that can help in recovery from RD. However, future steps will require confirmation with a more significant cohort of patients and an extension of the metabolomics evaluation to other problems concerning the different clinical aspects of BPPV, such as the high rate of relapse.

19.
Anim Genet ; 44(2): 193-6, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22548449

RESUMO

Five single-nucleotide polymorphisms (SNPs) located in the calpain 1, (mu/I) large subunit (CAPN1), calpastatin (CAST), and cathepsin D (CTSD) genes were analyzed in a large sample of Piemontese cattle. The aim of this study was to evaluate allele and genotype frequencies of these SNPs and to investigate associations of CAPN1, CAST, and CTSD gene variants with meat quality traits. Minor allele frequencies ranged from 30 to 48%. The presence of the A allele at CAPN530 increased yellowness and drip loss. The CAST282 G allele was associated with an increased drip loss compared to the C allele, and the CAST2959 A allele decreased redness compared to the G allele.


Assuntos
Proteínas de Ligação ao Cálcio/genética , Calpaína/genética , Catepsina D/genética , Bovinos/genética , Carne , Músculo Esquelético/crescimento & desenvolvimento , Polimorfismo de Nucleotídeo Único/genética , Análise de Variância , Animais , Teorema de Bayes , Frequência do Gene , Genótipo , Itália
20.
Brain Sci ; 13(8)2023 Jul 31.
Artigo em Inglês | MEDLINE | ID: mdl-37626506

RESUMO

BACKGROUND: To assess and compare binaural benefits and subjective satisfaction of active bone conduction implant (BCI) in patients with bilateral conductive or mixed hearing loss fitted with bilateral BCI and patients with monaural conductive hearing loss fitted with monaural BCI. METHODS: ITA Matrix test was performed both on patients affected by bilateral conductive or mixed hearing loss fitted with monaural bone conduction hearing implant (Bonebridge, Med-El) before and after implantation of contralateral bone conduction hearing implant and on patients with monaural conductive or mixed hearing loss before and after implantation of monaural BCI. The Abbreviated Profile of Hearing Aid Benefit (APHAB) questionnaire was administered to both groups of subjects and the results were compared with each other. RESULTS: Patients of group 1 reported a difference of 4.66 dB in the summation setting compared to 0.79 dB of group 2 (p < 0.05). In the squelch setting, group 1 showed a difference of 2.42 dB compared to 1.53 dB of group 2 (p = 0.85). In the head shadow setting, patients of group 1 reported a difference of 7.5 dB, compared to 4.61 dB of group 2 (p = 0.34). As for the APHAB questionnaire, group 1 reported a mean global score difference of 11.10% while group 2 showed a difference of -4.00%. CONCLUSIONS: Bilateral BCI in patients affected by bilateral conductive or mixed hearing loss might show more advantages in terms of sound localisation, speech perception in noise and subjective satisfaction if compared to unilateral BCI fitting in patients affected by unilateral conductive hearing impairment. This may be explained by the different individual transcranial attenuation of each subject, which might lead to different outcomes in terms of binaural hearing achievement. On the other hand, patients with unilateral conductive or mixed hearing loss fitted with monaural BCI achieved good results in terms of binaural hearing and for this reason, there is no absolute contraindication to implantation in those patients.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA