Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Water Sci Technol ; 82(1): 131-143, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32910798

RESUMO

Higher standards in the European Water Framework Directive and national directive demand advanced wastewater treatment for removal of nutrients and organic micropollutants before the discharge into water bodies. Systematic investigations regarding relative dosage and filtration processes for removal of flocculated solids are currently lacking. In this study, the performance of technologies for advanced removal of total phosphorus down to <100 µg/L with pile cloth-filtration (CF) and membrane filtration was verified and synergy effects for the removal of other contaminants were identified. The results show that an over-stoichiometric addition of coagulants of >5 mol Me3+/mol sRP was necessary to achieve soluble reactive phosphorus (sRP) concentrations of <50 µg/L in the effluent. After the coupled process of tertiary phosphorus removal and solids removal, the soluble non-reactive phosphorus (sNRP) concentration regulates the lowest total phosphorus effluent concentration. sNRP is also partially, but not completely, removed by the use of coagulants. CF has proven to be an alternative technology for the removal of phosphorus and total suspended solids below the detection limit.


Assuntos
Fósforo , Eliminação de Resíduos Líquidos , Filtração , Floculação , Águas Residuárias
2.
Fish Shellfish Immunol ; 74: 401-409, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29337249

RESUMO

Lactate dehydrogenase (LDH) is key for anaerobic glycolysis. LDH is induced by the hypoxia inducible factor -1 (HIF-1). HIF-1 induces genes involved in glucose metabolism and regulates cellular oxygen homeostasis. HIF-1 is formed by a regulatory α-subunit (HIF-1α) and a constitutive ß-subunit (HIF-1ß). The white spot syndrome virus (WSSV) induces anaerobic glycolysis in shrimp hemocytes, associated with lactate accumulation. Although infection and lactate production are associated, the LDH role in WSSV-infected shrimp has not been examined. In this work, the effects of HIF-1 silencing on the expression of two LDH subunits (LDHvan-1 and LDHvan-2) in shrimp infected with the WSSV were studied. HIF-1α transcripts increased in gills, hepatopancreas, and muscle after WSSV infection, while HIF-1ß remained constitutively expressed. The expression for both LDH subunits increased in each tissue evaluated during the WSSV infection, translating into increased enzyme activity. Glucose concentration increased in each tissue evaluated, while lactate increased in gills and hepatopancreas, but not in muscle. Silencing of HIF-1α blocked the increase of LDH expression and enzyme activity, along with glucose (all tissues) and lactate (gills and hepatopancreas) concentrations produced by WSSV infection. These results demonstrate that HIF-1 up regulates the expression of LDH subunits during WSSV infection, and that this induction contributes to substrate metabolism in energetically active tissues of infected shrimp.


Assuntos
Regulação da Expressão Gênica/imunologia , Fator 1 Induzível por Hipóxia/genética , Imunidade Inata/genética , L-Lactato Desidrogenase/genética , L-Lactato Desidrogenase/imunologia , Penaeidae/genética , Penaeidae/imunologia , Sequência de Aminoácidos , Animais , Proteínas de Artrópodes/química , Proteínas de Artrópodes/genética , Proteínas de Artrópodes/imunologia , Sequência de Bases , Perfilação da Expressão Gênica , Fator 1 Induzível por Hipóxia/metabolismo , L-Lactato Desidrogenase/química , Filogenia , Alinhamento de Sequência , Vírus da Síndrome da Mancha Branca 1/fisiologia
3.
Int J Sports Med ; 37(12): 979-985, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27557405

RESUMO

Regular physical activity (PA) decreases mortality risk in survivors of breast and colorectal cancer. Such impacts of exercise have prompted initiatives designed both to promote and adequately monitor PA in cancer survivors. This study examines the validity of 2 widely used self-report methods for PA determination, the International Physical Activity Questionnaire short version (IPAQ-SF) and Global Physical Activity Questionnaire (GPAQ). Both instruments were compared with the triaxial accelerometry (Actigraph) method as an objective reference standard. Study participants were 204 cancer survivors (both sexes, aged 18-79 years). Compared with accelerometry, both questionnaires significantly overestimated PA levels (across all intensities) and underestimated physical inactivity levels. No differences were detected between the 2 questionnaires except for a shorter inactivity time estimated by GPAQ (p=0.001). The Bland and Altman method confirmed that both questionnaires overestimated all PA levels. Receiver operating characteristic (ROC) analysis classified IPAQ and GPAQ as fair and poor predictors, respectively, of the proportions of survivors fulfilling international PA recommendations (≥150 min·week-1 of moderate-vigorous PA). IPAQ-SF showed a higher sensitivity but lower specificity than GPAQ. Our data do not support the use of IPAQ-SF or GPAQ to determine PA or inactivity levels in cancer survivors.


Assuntos
Atividade Motora/fisiologia , Neoplasias/reabilitação , Inquéritos e Questionários , Sobreviventes , Acelerometria , Adolescente , Adulto , Idoso , Estudos Transversais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Autorrelato , Sensibilidade e Especificidade , Espanha , Adulto Jovem
4.
Sci Rep ; 9(1): 20113, 2019 12 27.
Artigo em Inglês | MEDLINE | ID: mdl-31882988

RESUMO

Retinoblastoma represents 3% of cancers in children under fifteen years of age. The standard paediatric treatment for saving the affected eye is supraselective intra-arterial chemotherapy performed in interventional rooms. In order to address the radiation toxicity due to the angiography, the aim of this study was to determine the typical dose value corresponding to the procedure, estimate the paediatric patients' eye lens dose and study the relationship between dose indicators and dose to the lens. An automatic dose management software was installed in two interventional rooms to obtain the distribution of the dose indicators kerma-area product and reference-point air kerma, getting a typical value 16 Gy·cm2 and 130 mGy, respectively (n = 35). The eye lens dose estimates were obtained with photoluminescent dosimeters placed on the patient's eyelids. In the left eye, the entrance surface air kerma was 44.23 ± 2.66 mGy, and 12.72 ± 0.89 mGy in the right eye (n = 10). There was a positive correlation between dose to the lens per procedure and dose indicators, with R2 > 0.65 for both eyes. Based on this information, the threshold for the onset of radiation-induce cataracts (500 mGy) will be exceeded if the treatment is performed for more than 8 sessions.


Assuntos
Cristalino/efeitos da radiação , Exposição à Radiação/efeitos adversos , Neoplasias da Retina/complicações , Retinoblastoma/complicações , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Cristalino/patologia , Masculino , Doses de Radiação , Dosímetros de Radiação , Neoplasias da Retina/radioterapia , Retinoblastoma/radioterapia , Raios X
5.
Appl Radiat Isot ; 141: 130-137, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-30237096

RESUMO

This paper presents a fast method to estimate the annual eye lens dose levels for interventional practitioners applying the Monte Carlo method of uncertainty assessment. The estimation was performed by placing an anthropomorphic phantom in the typical working position, and applying the habitually employed protocol. No radiation protection devices were considered in the simulation. The results were compatible with the measurements performed during interventions by placing dosimeters in the vicinity of the eyes of two paediatric interventional cardiologists working with a fluoroscopic biplane system.


Assuntos
Fluoroscopia/efeitos adversos , Cristalino/efeitos da radiação , Exposição Ocupacional/efeitos adversos , Radiografia Intervencionista/efeitos adversos , Radiometria/estatística & dados numéricos , Simulação por Computador , Humanos , Método de Monte Carlo , Dosimetria por Luminescência Estimulada Opticamente/estatística & dados numéricos , Imagens de Fantasmas , Doses de Radiação , Exposição à Radiação/efeitos adversos , Proteção Radiológica , Software , Incerteza
6.
Br J Radiol ; 91(1086): 20180022, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29537302

RESUMO

Objective: The new 2013/59 EURATOM Directive (ED) demands dosimetric optimisation procedures without undue delay. The aim of this study was to optimise paediatric conventional radiology examinations applying the ED without compromising the clinical diagnosis. METHODS: Automatic dose management software (ADMS) was used to analyse 2678 studies of children from birth to 5 years of age, obtaining local diagnostic reference levels (DRLs) in terms of entrance surface air kerma. Given local DRL for infants and chest examinations exceeded the European Commission (EC) DRL, an optimisation was performed decreasing the kVp and applying the automatic control exposure. To assess the image quality, an analysis of high-contrast resolution (HCSR), signal-to-noise ratio (SNR) and figure of merit (FOM) was performed, as well as a blind test based on the generalised estimating equations method. RESULTS: For newborns and chest examinations, the local DRL exceeded the EC DRL by 113%. After the optimisation, a reduction of 54% was obtained. No significant differences were found in the image quality blind test. A decrease in SNR (-37%) and HCSR (-68%), and an increase in FOM (42%), was observed. CONCLUSION: ADMS allows the fast calculation of local DRLs and the performance of optimisation procedures in babies without delay. However, physical and clinical analyses of image quality remain to be needed to ensure the diagnostic integrity after the optimisation process. Advances in knowledge: ADMS are useful to detect radiation protection problems and to perform optimisation procedures in paediatric conventional imaging without undue delay, as ED requires.


Assuntos
Doses de Radiação , Radiografia Torácica/métodos , Radiometria/métodos , Software , Pré-Escolar , Humanos , Lactente , Recém-Nascido , Proteção Radiológica , Interpretação de Imagem Radiográfica Assistida por Computador
7.
Phys Med ; 36: 81-90, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28410690

RESUMO

PURPOSE: To analyse the correlations between the eye lens dose estimates performed with dosimeters placed next to the eyes of paediatric interventional cardiologists working with a biplane system, the personal dose equivalent measured on the thorax and the patient dose. METHODS: The eye lens dose was estimated in terms of Hp(0.07) on a monthly basis, placing optically stimulated luminescence dosimeters (OSLDs) on goggles. The Hp(0.07) personal dose equivalent was measured over aprons with whole-body OSLDs. Data on patient dose as recorded by the kerma-area product (PKA) were collected using an automatic dose management system. The 2 paediatric cardiologists working in the facility were involved in the study, and 222 interventions in a 1-year period were evaluated. The ceiling-suspended screen was often disregarded during interventions. RESULTS: The annual eye lens doses estimated on goggles were 4.13±0.93 and 4.98±1.28mSv. Over the aprons, the doses obtained were 10.83±0.99 and 11.97±1.44mSv. The correlation between the goggles and the apron dose was R2=0.89, with a ratio of 0.38. The correlation with the patient dose was R2=0.40, with a ratio of 1.79µSvGy-1cm-2. The dose per procedure obtained over the aprons was 102±16µSv, and on goggles 40±9µSv. The eye lens dose normalized to PKA was 2.21±0.58µSvGy-1cm-2. CONCLUSIONS: Measurements of personal dose equivalent over the paediatric cardiologist's apron are useful to estimate eye lens dose levels if no radiation protection devices are typically used.


Assuntos
Cardiologia , Fluoroscopia/efeitos adversos , Cristalino/efeitos da radiação , Doses de Radiação , Exposição à Radiação/análise , Radiologia Intervencionista , Calibragem , Criança , Humanos , Proteção Radiológica , Inquéritos e Questionários
8.
Appl Radiat Isot ; 103: 43-7, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26048324

RESUMO

Maximum Hp(0.07) dose to the eye lens received in a year by the pediatric interventional cardiologists has been estimated. Optically stimulated luminescence dosimeters were placed on the eyes of an anthropomorphic phantom, whose position in the room simulates the most common irradiation conditions. Maximum workload was considered with data collected from procedures performed in the Hospital. None of the maximum values obtained exceed the dose limit of 20 mSv recommended by ICRP.


Assuntos
Cardiologia/estatística & dados numéricos , Cristalino/efeitos da radiação , Exposição Ocupacional/estatística & dados numéricos , Pediatria/estatística & dados numéricos , Exposição à Radiação/estatística & dados numéricos , Radiografia Intervencionista/estatística & dados numéricos , Humanos , Exposição Ocupacional/análise , Doses de Radiação , Exposição à Radiação/análise , Espanha , Dosimetria Termoluminescente/estatística & dados numéricos , Carga de Trabalho/estatística & dados numéricos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA