Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 57
Filtrar
1.
J Clin Monit Comput ; 38(5): 1101-1115, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-39150462

RESUMO

Blood velocities measured by Transcranial Doppler (TCD) are dependent on the angle between the incident ultrasound beam and the direction of blood flow (known as the Doppler angle). However, when TCD examinations are performed without imaging the Doppler angle for each vessel segment is not known. We have measured Doppler angles in the basal cerebral arteries examined with TCD using three-dimensional (3D) vessel models generated from computed tomography angiography (CTA) scans. This approach produces angle statistics that are not accessible during non-imaging TCD studies. We created 3D models of the basal cerebral arteries for 24 vasospasm patients. Standard acoustic windows were mapped to the specific anatomy of each patient. Virtual ultrasound transmit beams were generated that originated from the acoustic window and intersected the centerline of each arterial segment. Doppler angle measurements were calculated and compiled for each vessel segment. Doppler angles were smallest for the middle cerebral artery M1 segment (median 24.6°) and ophthalmic artery (median 25.0°), and largest for the anterior cerebral artery A2 segment (median 76.4°) and posterior cerebral artery P2 segment (median 75.8°). The ophthalmic artery had the highest proportion of Doppler angles that were less than 60° (99%) while the anterior cerebral artery A2 segment had the lowest proportion of Doppler angles that were less than 60° (10%). These angle measurements indicate the expected deviation between measured and true velocities in the cerebral arteries, highlighting specific segments that may be prone to underestimation of velocity.


Assuntos
Circulação Cerebrovascular , Angiografia por Tomografia Computadorizada , Imageamento Tridimensional , Ultrassonografia Doppler Transcraniana , Humanos , Ultrassonografia Doppler Transcraniana/métodos , Angiografia por Tomografia Computadorizada/métodos , Imageamento Tridimensional/métodos , Feminino , Masculino , Velocidade do Fluxo Sanguíneo , Artérias Cerebrais/diagnóstico por imagem , Pessoa de Meia-Idade , Vasoespasmo Intracraniano/diagnóstico por imagem , Idoso , Adulto , Angiografia Cerebral/métodos , Artéria Oftálmica/diagnóstico por imagem
2.
Artif Organs ; 47(7): 1174-1183, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36906913

RESUMO

BACKGROUND: The standard weekly treatment for end-stage renal disease patients is three 4-h-long hemodialysis sessions with each session c'onsuming over 120 L of clean dialysate, which prevents the development of portable or continuous ambulatory dialysis treatments. The regeneration of a small (~1 L) amount of dialysate would enable treatments that give conditions close to continuous hemostasis and improve patient quality of life through mobility. METHODS: Small-scale studies have shown that nanowires of TiO2 are highly efficient at photodecomposing urea into CO2 and N2 when using an applied bias and an air permeable cathode. To enable the demonstration of a dialysate regeneration system at therapeutically useful rates, a scalable microwave hydrothermal synthesis of single crystal TiO2 nanowires grown directly from conductive substrates was developed. These were incorporated into 1810 cm2 flow channel arrays. The regenerated dialysate samples were treated with activated carbon (2 min at 0.2 g/mL). RESULTS: The photodecomposition system achieved the therapeutic target of 14.2 g urea removal in 24 h. TiO2 electrode had a high urea removal photocurrent efficiency of 91%, with less than 1% of the decomposed urea generating NH4 + (1.04 µg/h/cm2 ), 3% generating NO3 - and 0.5% generating chlorine species. Activated carbon treatment could reduce total chlorine concentration from 0.15 to <0.02 mg/L. The regenerated dialysate showed significant cytotoxicity which could be removed by treatment with activated carbon. Additionally, a forward osmosis membrane with sufficient urea flux can cut off the mass transfer of the by-products back into the dialysate. CONCLUSION: Urea could be removed from spent dialysate at a therapeutic rate using a TiO2 based photooxidation unit, which can enable portable dialysis systems.


Assuntos
Nanofios , Ureia , Humanos , Carvão Vegetal , Cloro , Qualidade de Vida , Diálise Renal , Soluções para Diálise/química
3.
J Biomech Eng ; 145(4)2023 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-36173034

RESUMO

The Circle of Willis (CoW) is a redundant network of blood vessels that perfuses the brain. The ringlike anatomy mitigates the negative effects of stroke by activating collateral pathways that help maintain physiological perfusion. Previous studies have investigated the activation of these pathways during embolic stroke and internal carotid artery occlusion. However, the role of collateral pathways during cerebral vasospasm-an involuntary constriction of blood vessels after subarachnoid hemorrhage-is not well-documented. This study presents a novel technique to create patient-specific computational fluid dynamics (CFD) simulations of the Circle of Willis before and during vasospasm. Computed tomographic angiography (CTA) scans are segmented to model the vasculature, and transcranial Doppler ultrasound (TCD) measurements of blood flow velocity are applied as boundary conditions. Bayesian analysis leverages information about the uncertainty in the measurements of vessel diameters and velocities to find an optimized parameter set that satisfies mass conservation and that is applied in the final simulation. With this optimized parameter set, the diameters, velocities, and flow rates fall within typical literature values. Virtual angiograms modeled using passive scalar transport agree closely with clinical angiography. A sensitivity analysis quantifies the changes in collateral flow rates with respect to changes in the inlet and outlet flow rates. This analysis can be applied in the future to a cohort of patients to investigate the relationship between the locations and severities of vasospasm, the patient-to-patient anatomical variability in the Circle of Willis, and the activation of collateral pathways.


Assuntos
Círculo Arterial do Cérebro , Hidrodinâmica , Círculo Arterial do Cérebro/diagnóstico por imagem , Teorema de Bayes , Circulação Colateral/fisiologia , Circulação Cerebrovascular/fisiologia , Velocidade do Fluxo Sanguíneo/fisiologia
4.
J Biomech Eng ; 145(4)2023 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-36193892

RESUMO

Successful occlusion of cerebral aneurysms using coil embolization is contingent upon stable thrombus formation, and the quality of the thrombus depends upon the biomechanical environment. The goal of this study was to investigate how coil embolization alters the mechanical micro-environment within the aneurysm dome. Inertialess particles were injected in three-dimensional, computational simulations of flow inside patient aneurysms using patient-specific boundary conditions. Coil embolization was simulated as a homogenous porous medium of known permeability and inertial constant. Lagrangian particle tracking was used to calculate the residence time and shear stress history for particles in the flow before and after treatment. The percentage of particles entering the aneurysm dome correlated with the neck surface area before and after treatment (pretreatment: R2 = 0.831, P < 0.001; post-treatment: R2 = 0.638, P < 0.001). There was an inverse relationship between the change in particles entering the dome and coil packing density (R2 = 0.600, P < 0.001). Following treatment, the particles with the longest residence times tended to remain within the dome even longer while accumulating lower shear stress. A significant correlation was observed between the treatment effect on residence time and the ratio of the neck surface area to porosity (R2 = 0.390, P = 0.007). The results of this study suggest that coil embolization triggers clot formation within the aneurysm dome via a low shear stress-mediated pathway. This hypothesis links independently observed findings from several benchtop and clinical studies, furthering our understanding of this treatment strategy.


Assuntos
Embolização Terapêutica , Aneurisma Intracraniano , Humanos , Aneurisma Intracraniano/terapia , Embolização Terapêutica/métodos , Prótese Vascular , Porosidade , Resultado do Tratamento
5.
J Biomech Eng ; 145(1)2023 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-35838329

RESUMO

Hemodynamic factors have long been associated with clinical outcomes in the treatment of cerebral aneurysms. Computational studies of cerebral aneurysm hemodynamics have provided valuable estimates of the mechanical environment experienced by the endothelium in both the parent vessel and aneurysmal dome walls and have correlated them with disease state. These computational-clinical studies have recently been correlated with the response of endothelial cells (EC) using either idealized or patient-specific models. Here, we present a robust workflow for generating anatomic-scale aneurysm models, establishing luminal cultures of ECs at physiological relevant flow profiles, and comparing EC responses to curvature mediated flow. We show that flow patterns induced by parent vessel curvature produce changes in wall shear stress (WSS) and wall shear stress gradients (WSSG) that are correlated with differences in cell morphology and cellular protein localization. Cells in higher WSS regions align better with the flow and display strong Notch1-extracellular domain (ECD) polarization, while, under low WSS, differences in WSSG due to curvature change were associated with less alignment and attenuation of Notch1-ECD polarization in ECs of the corresponding regions. These proof-of-concept results highlight the use of engineered cellularized aneurysm models for connecting computational fluid dynamics to the underlying endothelial biology that mediates disease.


Assuntos
Aneurisma Intracraniano , Células Endoteliais , Endotélio/metabolismo , Hemodinâmica/fisiologia , Humanos , Hidrodinâmica , Modelos Cardiovasculares , Estresse Mecânico
6.
J Biomech Eng ; 143(7)2021 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-33665669

RESUMO

As frequency of endovascular treatments for intracranial aneurysms increases, there is a growing need to understand the mechanisms for coil embolization failure. Computational fluid dynamics (CFD) modeling often simplifies modeling the endovascular coils as a homogeneous porous medium (PM), and focuses on the vascular wall endothelium, not considering the biomechanical environment of platelets. These assumptions limit the accuracy of computations for treatment predictions. We present a rigorous analysis using X-ray microtomographic imaging of the coils and a combination of Lagrangian (platelet) and Eulerian (endothelium) metrics. Four patient-specific, anatomically accurate in vitro flow phantoms of aneurysms are treated with the same patient-specific endovascular coils. Synchrotron tomography scans of the coil mass morphology are obtained. Aneurysmal hemodynamics are computationally simulated before and after coiling, using patient-specific velocity/pressure measurements. For each patient, we analyze the trajectories of thousands of platelets during several cardiac cycles, and calculate residence times (RTs) and shear exposure, relevant to thrombus formation. We quantify the inconsistencies of the PM approach, comparing them with coil-resolved (CR) simulations, showing the under- or overestimation of key hemodynamic metrics used to predict treatment outcomes. We fully characterize aneurysmal hemodynamics with converged statistics of platelet RT and shear stress history (SH), to augment the traditional wall shear stress (WSS) on the vascular endothelium. Incorporating microtomographic scans of coil morphology into hemodynamic analysis of coiled intracranial aneurysms, and augmenting traditional analysis with Lagrangian platelet metrics improves CFD predictions, and raises the potential for understanding and clinical translation of computational hemodynamics for intracranial aneurysm treatment outcomes.


Assuntos
Aneurisma Intracraniano
7.
Cardiovasc Eng Technol ; 15(2): 211-223, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38191806

RESUMO

PURPOSE: Intravascular endoscopy can aid in the diagnosis of coronary atherosclerosis by providing direct color images of coronary plaques. The procedure requires a blood-free optical path between the catheter and plaque, and achieving clearance safely remains an engineering challenge. In this study, we investigate the hemodynamics of saline flushing in partially occluded coronary arteries to advance the development of intravascular forward-imaging catheters that do not require balloon occlusion. METHODS: In-vitro experiments and CFD simulations are used to quantify the influence of plaque size, catheter stand-off distance, saline injection flowrate, and injection orientation on the time required to achieve blood clearance. RESULTS: Experiments and simulation of saline injection from a dual-lumen catheter demonstrated that flushing times increase both as injection flow rate (Reynolds number) decreases and as the catheter moves distally away from the plaque. CFD simulations demonstrated that successful flushing was achieved regardless of lumen axial orientation in a 95% occluded artery. Flushing time was also found to increase as plaque size decreases for a set injection flowrate, and a lower limit for injection flowrate was found to exist for each plaques size, below which clearance was not achieved. For the three occlusion sizes investigated (90, 95, 97% by area), successful occlusion was achieved in less than 1.2 s. Investigation of the pressure fields developed during injection, highlight that rapid clearance can be achieved while keeping the arterial overpressure to < 1 mmHg. CONCLUSIONS: A dual lumen saline injection catheter was shown to produce clearance safely and effectively in models of partially occluded coronary arteries. Clearance was achieved across a range of engineering and clinical parameters without the use of a balloon occlusion, providing development guideposts for a fluid injection system in forward-imaging coronary endoscopes.


Assuntos
Vasos Coronários , Hemodinâmica , Modelos Cardiovasculares , Solução Salina , Solução Salina/administração & dosagem , Vasos Coronários/fisiopatologia , Vasos Coronários/diagnóstico por imagem , Humanos , Simulação por Computador , Circulação Coronária , Placa Aterosclerótica , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/fisiopatologia , Doença da Artéria Coronariana/terapia , Desenho de Equipamento , Cateteres Cardíacos , Endoscopia/instrumentação , Oclusão Coronária/diagnóstico por imagem , Oclusão Coronária/fisiopatologia , Oclusão Coronária/terapia , Fatores de Tempo
8.
J Clin Med ; 13(2)2024 Jan 18.
Artigo em Inglês | MEDLINE | ID: mdl-38256685

RESUMO

Minimally-invasive therapies are well-established treatment methods for saccular intracranial aneurysms (SIAs). Knowledge concerning fusiform IAs (FIAs) is low, due to their wide and alternating lumen and their infrequent occurrence. However, FIAs carry risks like ischemia and thus require further in-depth investigation. Six patient-specific IAs, comprising three position-identical FIAs and SIAs, with the FIAs showing a non-typical FIA shape, were compared, respectively. For each model, a healthy counterpart and a treated version with a flow diverting stent were created. Eighteen time-dependent simulations were performed to analyze morphological and hemodynamic parameters focusing on the treatment effect (TE). The stent expansion is higher for FIAs than SIAs. For FIAs, the reduction in vorticity is higher (Δ35-75% case 2/3) and the reduction in the oscillatory velocity index is lower (Δ15-68% case 2/3). Velocity is reduced equally for FIAs and SIAs with a TE of 37-60% in FIAs and of 41-72% in SIAs. Time-averaged wall shear stress (TAWSS) is less reduced within FIAs than SIAs (Δ30-105%). Within this study, the positive TE of FDS deployed in FIAs is shown and a similarity in parameters found due to the non-typical FIA shape. Despite the higher stent expansion, velocity and vorticity are equally reduced compared to identically located SIAs.

9.
Ann Biomed Eng ; 52(6): 1763-1778, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38517620

RESUMO

Patients with advanced heart failure are implanted with a left ventricular assist device (LVAD) as a bridge-to-transplantation or destination therapy. Despite advances in pump design, the risk of stroke remains high. LVAD implantation significantly alters intraventricular hemodynamics, where regions of stagnation or elevated shear stresses promote thrombus formation. Third generation pumps incorporate a pulsatility mode that modulates rotational speed of the pump to enhance in-pump washout. We investigated how the timing of the pulsatility mode with the cardiac cycle affects intraventricular hemodynamic factors linked to thrombus formation. Computational fluid dynamics simulations with Lagrangian particle tracking to model platelet behavior in a patient-specific left ventricle captured altered intraventricular hemodynamics due to LVAD implantation. HeartMate 3 incorporates a pulsatility mode that modulates the speed of the pump every two seconds. Four different timings of this pulsatility mode with respect to the cardiac cycle were investigated. A strong jet formed between the mitral valve and inflow cannula. Blood stagnated in the left ventricular outflow tract beneath a closed aortic valve, in the near-wall regions off-axis of the jet, and in a large counterrotating vortex near the anterior wall. Computational results showed good agreement with particle image velocimetry results. Synchronization of the pulsatility mode with peak systole decreased stasis, reflected in the intraventricular washout of virtual contrast and Lagrangian particles over time. Temporal synchronization of HeartMate 3 pulsatility with the cardiac cycle reduces intraventricular stasis and could be beneficial for decreasing thrombogenicity.


Assuntos
Coração Auxiliar , Hemodinâmica , Modelos Cardiovasculares , Humanos , Ventrículos do Coração , Simulação por Computador , Trombose/fisiopatologia , Insuficiência Cardíaca/fisiopatologia
10.
Int J Artif Organs ; 47(5): 329-337, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38742880

RESUMO

BACKGROUND: This study investigates the hypothesis that presence of atrial fibrillation (AF) in LVAD patients increases thrombogenicity in the left ventricle (LV) and exacerbates stroke risk. METHODS: Using an anatomical LV model implanted with an LVAD inflow cannula, we analyze thrombogenic risk and blood flow patterns in either AF or sinus rhythm (SR) using unsteady computational fluid dynamics (CFD). To analyze platelet activation and thrombogenesis in the LV, hundreds of thousands of platelets are individually tracked to quantify platelet residence time (RT) and shear stress accumulation history (SH). RESULTS: The irregular and chaotic mitral inflow associated with AF results in markedly different intraventricular flow patterns, with profoundly negative impact on blood flow-induced stimuli experienced by platelets as they traverse the LV. Twice as many platelets accumulated very high SH in the LVAD + AF case, resulting in a 36% increase in thrombogenic potential score, relative to the LVAD + SR case. CONCLUSIONS: This supports the hypothesis that AF results in unfavorable blood flow patterns in the LV adding to an increased stroke risk for LVAD + AF patients. Quantification of thrombogenic risk associated with AF for LVAD patients may help guide clinical decision-making on interventions to mitigate the increased risk of thromboembolic events.


Assuntos
Fibrilação Atrial , Coração Auxiliar , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/etiologia , Coração Auxiliar/efeitos adversos , Humanos , Trombose/etiologia , Trombose/fisiopatologia , Ativação Plaquetária , Modelos Cardiovasculares , Ventrículos do Coração/fisiopatologia , Ventrículos do Coração/diagnóstico por imagem , Acidente Vascular Cerebral/etiologia , Plaquetas/metabolismo , Função Ventricular Esquerda , Modelos Anatômicos , Hidrodinâmica , Hemodinâmica
11.
Ann Biomed Eng ; 52(9): 2417-2439, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38758460

RESUMO

The Circle of Willis (CoW) is a ring-like network of blood vessels that perfuses the brain. Flow in the collateral pathways that connect major arterial inputs in the CoW change dynamically in response to vessel narrowing or occlusion. Vasospasm is an involuntary constriction of blood vessels following subarachnoid hemorrhage (SAH), which can lead to stroke. This study investigated interactions between localization of vasospasm in the CoW, vasospasm severity, anatomical variations, and changes in collateral flow directions. Patient-specific computational fluid dynamics (CFD) simulations were created for 25 vasospasm patients. Computed tomographic angiography scans were segmented capturing the anatomical variation and stenosis due to vasospasm. Transcranial Doppler ultrasound measurements of velocity were used to define boundary conditions. Digital subtraction angiography was analyzed to determine the directions and magnitudes of collateral flows as well as vasospasm severity in each vessel. Percent changes in resistance and viscous dissipation were analyzed to quantify vasospasm severity and localization of vasospasm in a specific region of the CoW. Angiographic severity correlated well with percent changes in resistance and viscous dissipation across all cerebral vessels. Changes in flow direction were observed in collateral pathways of some patients with localized vasospasm, while no significant changes in flow direction were observed in others. CFD simulations can be leveraged to quantify the localization and severity of vasospasm in SAH patients. These factors as well as anatomical variation may lead to changes in collateral flow directions. Future work could relate localization and vasospasm severity to clinical outcomes like the development of infarct.


Assuntos
Circulação Cerebrovascular , Círculo Arterial do Cérebro , Modelos Cardiovasculares , Vasoespasmo Intracraniano , Humanos , Círculo Arterial do Cérebro/fisiopatologia , Círculo Arterial do Cérebro/diagnóstico por imagem , Vasoespasmo Intracraniano/fisiopatologia , Vasoespasmo Intracraniano/diagnóstico por imagem , Feminino , Masculino , Pessoa de Meia-Idade , Hidrodinâmica , Idoso , Circulação Colateral , Adulto
12.
Med Phys ; 51(2): 1499-1508, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38150511

RESUMO

BACKGROUND: Computational fluid dynamics (CFD) simulations are a powerful tool for studying cerebral aneurysms, capable of evaluating hemodynamics in a way that is infeasible with imaging alone. However, the difficulty of incorporating patient-specific information and inherent obstacles of in vivo validation have limited the clinical usefulness of CFD of cerebral aneurysms. In this work we investigate the effect of using standardized blood viscosity values in CFD simulations of cerebral aneurysms when compared to simulations of the same aneurysms using patient-specific viscosity values derived from hematocrit measurements. PURPOSE: The objective of this work is to determine the level of error, on average, that is, caused by using standardized values of viscosity in CFD simulations of cerebral aneurysms. By quantifying this error, we demonstrate the need for incorporating patient-specific viscosity in future CFD investigations of cerebral aneurysms. METHODS: CFD simulations of forty-one cerebral aneurysms were conducted using patient-specific boundary conditions. For each aneurysm two simulations were conducted, one utilizing patient-specific blood viscosity derived from hematocrit measurements and another using a standardized value for blood viscosity. Hemodynamic parameters such as wall shear stress (WSS), wall shear stress gradient (WSSG), and the oscillatory shear index (OSI) were calculated for each of the simulations for each aneurysm. Paired t-tests for differences in the time-averaged maps of these hemodynamic parameters between standardized and patient-specific viscosity simulations were conducted for each aneurysm. Bland-Altman analysis was used to examine the cohort-wide changes in the hemodynamic parameters. Subjects were broken into two groups, those with higher than standard viscosity and those with lower than standard viscosity. An unpaired t-test was used to compare the percent change in WSS, WSSG, and OSI between patient-specific and standardized viscosity simulations for the two cohorts. The percent changes in hemodynamic parameters were correlated against the direction and magnitude of percent change in viscosity, aneurysm size, and aneurysm location. For all t-tests, a Bonferroni-corrected significance level of 0.0167 was used. RESULTS: 63.2%, 41.5%, and 48.7% of aneurysms showed statistically significant differences between patient-specific and standardized viscosity simulations for WSS, WSSG, and OSI respectively. No statistically significant difference was found in the percent changes in WSS, WSSG, and OSI between the group with higher than standard viscosity and those with lower than standard viscosity, indicating an increase in viscosity can cause either an increase or decrease in each of the hemodynamic parameters. On a study-wide level no significant bias was found in either direction for WSS, WSSG, or OSI between the simulation groups due to the bidirectional effect of changing viscosity. No correlation was found between percent change of viscosity and percent change of WSS, WSSG, or OSI, meaning an after-the-fact correction for patient-specific viscosity is not feasible. CONCLUSION: Standardizing viscosity values in CFD of cerebral aneurysms has a large and unpredictable impact on the calculated WSS, WSSG, and OSI when compared to CFD simulations of the same aneurysms using a patient-specific viscosity. We recommend implementing hematocrit-based patient-specific blood viscosity values for all CFD simulations of cerebral aneurysms.


Assuntos
Aneurisma Intracraniano , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Viscosidade , Hidrodinâmica , Hemodinâmica , Estresse Mecânico , Modelos Cardiovasculares
13.
Otolaryngol Head Neck Surg ; 170(4): 1195-1199, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38168480

RESUMO

Endoscopy is the gold standard for characterizing pediatric airway disorders, however, it is limited for quantitative analysis due to lack of three-dimensional (3D) vision and poor stereotactic depth perception. We utilize structure from motion (SfM) photogrammetry, to reconstruct 3D surfaces of pathologic and healthy pediatric larynges from monocular two-dimensional (2D) endoscopy. Models of pediatric subglottic stenosis were 3D printed and airway endoscopies were simulated. 3D surfaces were successfully reconstructed from endoscopic videos of all models using an SfM analysis toolkit. Average subglottic surface error between SfM reconstructed surfaces and 3D printed models was 0.65 mm as measured by Modified Hausdorff Distance. Average volumetric similarity between SfM surfaces and printed models was 0.82 as measured by Jaccard Index. SfM can be used to accurately reconstruct 3D surface renderings of the larynx from 2D endoscopy video. This technique has immense potential for use in quantitative analysis of airway geometry and virtual surgical planning.


Assuntos
Laringe , Humanos , Criança , Projetos Piloto , Laringe/diagnóstico por imagem , Laringe/cirurgia , Endoscopia/métodos , Sistema Respiratório , Imageamento Tridimensional/métodos , Fotogrametria/métodos
14.
J Biomech Eng ; 135(1): 011005, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23363216

RESUMO

Arteriovenous fistulae are surgically created to provide adequate access for dialysis patients suffering from end-stage renal disease. It has long been hypothesized that the rapid blood vessel remodeling occurring after fistula creation is, in part, a process to restore the mechanical stresses to some preferred level, i.e., mechanical homeostasis. We present computational hemodynamic simulations in four patient-specific models of mature arteriovenous fistulae reconstructed from 3D ultrasound scans. Our results suggest that these mature fistulae have remodeled to return to ''normal'' shear stresses away from the anastomoses: about 1.0 Pa in the outflow veins and about 2.5 Pa in the inflow arteries. Large parts of the anastomoses were found to be under very high shear stresses >15 Pa, over most of the cardiac cycle. These results suggest that the remodeling process works toward restoring mechanical homeostasis in the fistulae, but that the process is limited or incomplete, even in mature fistulae, as evidenced by the elevated shear at or near the anastomoses. Based on the long term clinical viability of these dialysis accesses, we hypothesize that the elevated nonhomeostatic shear stresses in some portions of the vessels were not detrimental to fistula patency.


Assuntos
Fístula Arteriovenosa , Derivação Arteriovenosa Cirúrgica , Homeostase , Estresse Mecânico , Adulto , Idoso , Idoso de 80 Anos ou mais , Fenômenos Biomecânicos , Hemodinâmica , Humanos , Hidrodinâmica , Imageamento Tridimensional , Modelos Biológicos , Diálise Renal , Resistência ao Cisalhamento
15.
ASAIO J ; 69(6): 533-543, 2023 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-36881637

RESUMO

Thromboembolic events remain a common complication for left ventricular assist device (LVAD) patients. To prevent in-pump thrombosis, third-generation LVADs use speed modulation, which is not synchronized with the native left ventricle (LV) contractility. This study aims to investigate the effect of speed modulation on intraventricular flow patterns, and specifically, the impact of timing relative to pressure variations in the LV. Stereo-particle image velocimetry measurements were performed in a patient-derived LV implanted with an LVAD, for different timings of the speed modulation and speed. Speed modulation has a strong effect on instantaneous afterload and flowrate (-16% and +20%). The different timings of the speed modulation resulted in different flowrate waveforms, exhibiting different maxima (5.3-5.9 L/min, at constant average flowrate). Moreover, the timing of the speed modulation was found to strongly influence intraventricular flow patterns, specifically, stagnation areas within the LV. These experiments highlight, once more, the complex relationship between LVAD speed, hemodynamic resistance, and intraventricular pressure. Overall, this study demonstrates the importance of considering native LV contractility in future LVAD controls, to improve hemocompatibility and reduce the risk of thromboembolic complications.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Humanos , Coração Auxiliar/efeitos adversos , Hemodinâmica , Ventrículos do Coração , Insuficiência Cardíaca/cirurgia , Insuficiência Cardíaca/etiologia
16.
Ann Biomed Eng ; 51(12): 2785-2801, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37598136

RESUMO

Modeling blood flow in aneurysms treated with coils could be used to understand the complete embolization of the aneurysm, through thrombus formation that fills the entire sac. Modeling of the endovascular coil mass as a porous medium is a technique that allows for study of aneurysm hemodynamics, efficiently for patient-specific treatment outcome predictions. Models in the literature use mean porosity of coils in the aneurysmal volume, proving inadequate for outcome prediction. However, models that consider heterogeneous porosity distribution have shown more accurate hemodynamics. We recently published the porous crown model, considering the heterogeneous coil mass distribution, validated on two patients. This study aims (i) to validate the porous crown model for a larger cohort (eight patients), and (ii) to propose a porous medium model translatable to clinical practice in treatment planning. We analyzed the porosity distribution of the endovascular coils deployed inside the cerebral aneurysm phantoms of eight patients using 3D x-ray synchrotron images. The permeability and inertial factor of the porous crown model are calculated using previously published methodology. We propose a new "bilinear" porous model, that uses the same hypothesis, but the permeability and inertial factor can be defined from just basic information available in the neuro-suite, i.e., the aneurysmal sac volume and the coil volume fraction targeted by the neurosurgeon. These two models are compared to the coil-resolved simulations, considered as the gold standard. The results show that both the porous crown model and the bilinear model produce similarly accurate hemodynamics in the aneurysm. The error in the standard (mean porosity) porous model is 66%, whereas the error of the bilinear model is 26%, compared to the coil-resolved. The bilinear model is promising as a means of treatment outcome prediction at time of intervention.


Assuntos
Embolização Terapêutica , Aneurisma Intracraniano , Humanos , Porosidade , Hemodinâmica/fisiologia , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/terapia , Resultado do Tratamento , Embolização Terapêutica/métodos
17.
Ann Biomed Eng ; 51(2): 363-376, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35951208

RESUMO

Robin Sequence (RS) is a potentially fatal craniofacial condition characterized by undersized jaw, posteriorly displaced tongue, and resultant upper airway obstruction (UAO). Accurate assessment of UAO severity is crucial for management and diagnosis of RS, yet current evaluation modalities have significant limitations and no quantitative measures of airway resistance exist. In this study, we combine 4-dimensional computed tomography and computational fluid dynamics (CFD) to assess, for the first time, UAO severity using fluid dynamic metrics in RS patients. Dramatic intrapopulation differences are found, with the ratio between most and least severe patients in breathing resistance, energy loss, and peak velocity equal to 40:1, 20:1, and 6:1, respectively. Analysis of local airflow dynamics characterized patients as presenting with primary obstructions either at the location of the tongue base, or at the larynx, with tongue base obstructions resulting in a more energetic stenotic jet and greater breathing resistance. Finally, CFD-derived flow metrics are found to correlate with the level of clinical respiratory support. Our results highlight the large intrapopulation variability, both in quantitative metrics of UAO severity (resistance, energy loss, velocity) and in the location and intensity of stenotic jets for RS patients. These results suggest that computed airflow metrics may significantly improve our understanding of UAO and its management in RS.


Assuntos
Laringe , Síndrome de Pierre Robin , Humanos , Lactente , Hidrodinâmica , Síndrome de Pierre Robin/diagnóstico por imagem , Traqueia , Tomografia Computadorizada por Raios X , Constrição Patológica
18.
Cardiovasc Eng Technol ; 14(1): 115-128, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-35879587

RESUMO

PURPOSE: Computational fluid dynamics (CFD) has been used to evaluate the efficiency of endovascular treatment in coiled cerebral aneurysms. The explicit geometry of the coil mass cannot typically be incorporated into CFD simulations since the coil mass cannot be reconstructed from clinical images due to its small size and beam hardening artifacts. The existing methods use imprecise porous medium representations. We propose a new porous model taking into account the porosity heterogeneity of the coils deployed in the aneurysm. METHODS: The porosity heterogeneity of the coil mass deployed inside two patients' cerebral aneurysm phantoms is first quantified based on 3D X-ray synchrotron images. These images are also used to compute the permeability and the inertial factor arising in porous models. A new homogeneous porous model (porous crowns model), considering the coil's heterogeneity, is proposed to recreate the flow within the coiled aneurysm. Finally, the validity of the model is assessed through comparisons with coil-resolved simulations. RESULTS: The strong porosity gradient of the coil measured close to the aneurysmal wall is well captured by the porous crowns model. The permeability and the inertial factor values involved in this model are closed to the ideal homogeneous porous model leading to a mean velocity in the aneurysmal sac similar as in the coil-resolved model. CONCLUSION: The porous crowns model allows for an accurate description of the mean flow within the coiled cerebral aneurysm.


Assuntos
Embolização Terapêutica , Procedimentos Endovasculares , Aneurisma Intracraniano , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/terapia , Porosidade , Embolização Terapêutica/efeitos adversos , Hidrodinâmica
19.
Sci Robot ; 8(82): eadg4276, 2023 Sep 27.
Artigo em Inglês | MEDLINE | ID: mdl-37703382

RESUMO

Using wind to disperse microfliers that fall like seeds and leaves can help automate large-scale sensor deployments. Here, we present battery-free microfliers that can change shape in mid-air to vary their dispersal distance. We designed origami microfliers using bistable leaf-out structures and uncovered an important property: A simple change in the shape of these origami structures causes two dramatically different falling behaviors. When unfolded and flat, the microfliers exhibit a tumbling behavior that increases lateral displacement in the wind. When folded inward, their orientation is stabilized, resulting in a downward descent that is less influenced by wind. To electronically transition between these two shapes, we designed a low-power electromagnetic actuator that produces peak forces of up to 200 millinewtons within 25 milliseconds while powered by solar cells. We fabricated a circuit directly on the folded origami structure that includes a programmable microcontroller, a Bluetooth radio, a solar power-harvesting circuit, a pressure sensor to estimate altitude, and a temperature sensor. Outdoor evaluations show that our 414-milligram origami microfliers were able to electronically change their shape mid-air, travel up to 98 meters in a light breeze, and wirelessly transmit data via Bluetooth up to 60 meters away, using only power collected from the sun.

20.
J Biomech ; 157: 111733, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37527606

RESUMO

Cerebral aneurysms are a serious clinical challenge, with ∼half resulting in death or disability. Treatment via endovascular coiling significantly reduces the chances of rupture, but the techniquehas failure rates of ∼20 %. This presents a pressing need to develop a method fordetermining optimal coildeploymentstrategies. Quantification of the hemodynamics of coiled aneurysms using computational fluid dynamics (CFD) has the potential to predict post-treatment outcomes, but representing the coil mass in CFD simulations remains a challenge. We use the Finite Element Method (FEM) for simulating patient-specific coil deployment for n = 4 ICA aneurysms for which 3D printed in vitro models were also generated, coiled, and scanned using ultra-high resolution synchrotron micro-CT. The physical and virtual coil geometries were voxelized onto a binary structured grid and porosity maps were generated for geometric comparison. The average binary accuracy score is 0.8623 and the average error in porosity map is 4.94 %. We then conduct patient-specific CFD simulations of the aneurysm hemodynamics using virtual coils geometries, micro-CT generated oil geometries, and using the porous medium method to represent the coil mass. Hemodynamic parameters including Neck Inflow Rate (Qneck) and Wall Shear Stress (WSS) were calculated for each of the CFD simulations. The average relative error in Qneck and WSS from CFD using FEM geometry were 6.6 % and 21.8 % respectively, while the error from CFD using a porous media approximation resulted in errors of 55.1 % and 36.3 % respectively; demonstrating a marked improvement in the accuracy of CFD simulations using FEM generated coil geometries.


Assuntos
Aneurisma Intracraniano , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/terapia , Hidrodinâmica , Análise de Elementos Finitos , Hemodinâmica , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA